r
1.Application
This technical literature applies to the color 60.0” TFT-LCD Open Cell LK600D3HA19.
* This technical literature is proprietary products of SHARP CORPORATION (“SHARP”) and includes
materials protected under copyright of SHARP. Do not reproduce or cause any third party to reproduce them in
any form or by any means, electronic or mechanical, for any purpose, in whole or in part, without the express
written permission of SHARP.
* In case of using the device for applications such as control and safety equipment for transportation (aircraft,
trains, automobiles, etc.), rescue and security equipment and various safety related equipment which require
higher reliability and safety, take into consideration that appropriate measures such as fail-safe functions and
redundant system design should be taken.
* Do not use the device for equipment that requires an extreme level of reliability, such as aerospace
applications, telecommunication equipment (trunk lines), nuclear power control equipment and medical or other
equipment for life support.
* SHARP assumes no responsibility for any damage resulting from the use of the device that does not comply
with the instructions and the precautions specified in this technical literature.
* Contact and consult with a SHARP sales representative for any questions about this device.
2.Overview
This Open Cell is color active matrix LCD Open Cell incorporating amorphous silicon TFT (T
ransistor). It is composed of a color TFT-LCD panel, driver ICs and Source PWB.
T
The following contents can be achieved in using LK0DZ1C0xxx (C-PWB) and LK0DZ1C0xxx (CS-FPC) that
SHARP specifies.
Graphics and texts can be displayed on a 1920 x RGB x 1080 dots panel with one billion colors by using
10bit+LVDS (L
And in order to improve the response time of LCD, this module applies the Over Shoot driving (O/S driving)
technology for the control circuit. In the O/S driving technology, signals are being applied to the Liquid Crystal
according to a pre-fixed process as an image signal of the present frame when a difference is found between
image signal of the previous frame and that of the current frame after comparing them.
With combination of these technologies, motion blur can be reduced and clearer display performance can be
realized.
㻌
ow Voltage Differential Signaling) to interface, +12V of DC supply voltages.
www.panelook.com
LD-K23453-1
hin Film
TFT LCD Panel
(1920 x RGB x 1080)
Open Cell
[LK600D3HA19]
Gate Drive
Source Drive
Source PWB (S-PWB)
SS-FPC
CS-FPC
[LK0DZ1C0xxx
CN101
Control PWB (C-PWB)
[LK0DZ1C0xxx]
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
r
m
r
3.Mechanical Specifications
Paramete
SpecificationsUnit
Display size
Active area 1329.12(H) x 747.63 (V)mm
Pixel Format
Pixel pitch 0.69225(H) x 0.69225 (V)mm
Pixel configuration R, G, B vertical stripe
Display mode Normally black
Open Cell Outline Dimensions
[Note1]
Mass
Surface treatment
[Note2]
[Note1] Outline dimensions are shown in P17.
[Note2] With the protection film removed.
4.Open Cell Driving Specifications
4.1. Driving interface of C-PWB SHARP specifies [LK0DZ1C0xxx]
It is required to set non-connection(OPEN)
It is required to set non-connection(OPEN)
It is required to set non-connection(OPEN)
It is required to set non-connection(OPEN)
It is required to set non-connection(OPEN)
Select LVDS data order [Note1,2]
It is required to set non-connection(OPEN)
It is required to set non-connection(OPEN)
www.panelook.com
152.496 (Diagonal)c
60.0 (Diagonal)inch
1920(H) x 1080(V)
(1pixel = R + G + B dot)
1364.18(W) x 806.05(H) x 3.5(D)
4.2
r
0.3
- Front polarize
Hard coating: 2H and more
- Rear polarizer :
Hard coating less
: Anti Glare, Low Haze
Pull up : (3.3V)
LD-K23453-2
pixel
mm
kg
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
AIN4- Aport (-)LVDS CH4 differential data input
AIN4+ Aport (+)LVDS CH4 differential data input
GND
GND
BIN0- Bport (-)LVDS CH0 differential data input
BIN0+ Bport (+)LVDS CH0 differential data input
BIN1- Bport (-)LVDS CH1 differential data input
BIN1+ Bport (+)LVDS CH1 differential data input
BIN2- Bport (-)LVDS CH2 differential data input
BIN2+ Bport (+)LVDS CH2 differential data input
GND
BCK- Bport LVDS Clock signal(-)
BCK+ Bport LVDS Clock signal(+)
GND
BIN3- Bport (-)LVDS CH3 differential data input
BIN3+ Bport (+)LVDS CH3 differential data input
BIN4- Bport (-)LVDS CH4 differential data input
BIN4+ Bport (+)LVDS CH4 differential data input
GND
GND
GND
GND
GND
VCC +12V Power Supply
VCC +12V Power Supply
VCC +12V Power Supply
VCC +12V Power Supply
VCC +12V Power Supply
[Note] GND of a liquid crystal panel drive part should be connected with a module chassis.
[Note1] The equivalent circuit figure of the terminal.
www.panelook.com
LD-K23453-3
3.3V
100ohm
Ter mi na l
10kohm
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
[Note2] LVDS Data order
Data
TA0
TA1
TA2
TA3
TA4
TA5
TA6
TB0
TB1
TB2
TB3
TB4
TB5
TB6
TC0
TC1
TC2
TC3
TC4 NA NA
TC5 NA NA
TC6 DE(*) DE(*)
TD0
TD1
TD2
TD3
TD4
TD5
TD6
TE0
TE1
TE2
TE3
TE4
TE5
TE6
NA: Not Available
(*)Since the display position is prescribed by the rise of DE(Display Enable)signal, please do not fix DE
signal during operation at ”High”.