Sharp KCA50JW, KCA60JW User Manual

KC-A60J KC-A50J
Device of this mark is a trademark of Sharp Corporation. Plasmacluster is a registered trademark or a trademark of Sharp Corporation.
R
AIR PURIFIER with Humidifying Function
Free standing type
SHARP CORPORATION
OSAKA, JAPAN
OM_KC-A60J_EN.indd 1OM_KC-A60J_EN.indd 1 11/26/12 10:28:49 AM11/26/12 10:28:49 AM
* The number in this technology mark indicates an
approximate number of ions supplied into air of 1 cm which is measured around the center of a room with the “high-density plasmacluser 7000” applicable floor area (at 1.2 m height above the floor) at the medium wind volume in humidifying & air purifying mode, or in air purifying mode, when a humidifi er/air purifi er or an air purifier using the high-density plasmacluster ion evolving device is placed close to a wall. This product is equipped with a device corresponding to this capacity.
3
,
Please read before operating your new Air Purifi er
The air purifi er draws in room air from the air intake, passes the air through a Pre- Filter, a Washable Deodorizing Filter and a HEPA Filter inside of the unit, then discharges the air through the air outlet. The HEPA Filter can remove 99.97% of dust particles as small as 0.3 microns that pass through the fi lter and also helps absorb odours. The Washable Deodorizing Filter gradually absorbs odours as they pass through the lter.
Some odours absorbed by the fi lters may break down over time, resulting in additional odour. Depending on the usage environment, especially when the product is used in extreme environments (significantly more severe than normal household use), this odour may become strong in a shorter period than expected. If the odour persists, the
lters should be replaced.
NOTE
• The air purifi er is designed to remove air-suspended dust and odour, but not harmful gases (for example, carbon monoxide contained in cigarette smoke). If the source of the odour still exists, the air purifi er may not completely remove the odour.
HEPA Filter
Deodorizing Filter
Pre-Filter
(Common illustration has used “KC-A60J”.)
OM_KC-A60J_EN.indd 2OM_KC-A60J_EN.indd 2 11/26/12 10:28:49 AM11/26/12 10:28:49 AM
ENGLISH
FEATURES
Unique Combination of Air Treatment Technologies Triple Filtration System + Plasmacluster + Humidifi cation
TRAPS DUST*
Washable pre-filter traps dust and other large airborne particles.
DECREASES ODOURS
Washable deodorizing fi lter absorbs many common household odours.
REDUCES POLLEN & MOLD*
HEPA filter traps 99.97% of particles as small as 0.3 microns.
FRESHENS
Plasmacluster treats the air similar to the way nature cleans the environment by emitting a balance of positive and negative ions.
HUMIDIFIES
Runs up to 10 hours per fi lling.** *
When air is drawn through the fi lter system.
** Room size: up to 48 m2 (KC-A60J) up to 38 m2 (KC-A50J) (Room height 2.4m)
Sensor Technology continuously monitors air quality, and automatically adjusting operation based on detected air purity and humidity.
CONTENTS
IMPORTANT SAFETY INSTRUCTIONS
• WARNING
• CAUTIONS CONCERNING OPERATION
• INSTALLATION GUIDELINES
• FILTER GUIDELINES
PART NAMES
• FRONT / BACK
• MAIN UNIT DISPLAY
• ILLUSTRATIVE DIAGRAM
PREPARATION
• FILTER INSTALLATION
• REFILLING THE WA TER TANK
OPERATION
• CLEAN AIR & HUMIDIFY
• CLEAN AIR
• CLEAN ION SHOWER
• FAN SPEED
• PLASMACLUSTER ION ON/OFF
USEFUL FUNCTION
• LIGHTS CONTROL
• CHILD LOCK
• SOUND INDICATOR SETTING
• ADJUSTMENT OF SENSOR DETECTION SENSITIVITY
CARE AND MAINTENANCE
• FILTER INDICATOR
• CARE INDEX
• HUMIDIFYING DISINSTALLATION
• WATER TANK
• HUMIDIFYING FILTER
• HUMIDIFYING TRAY AND COVER
• BACK PANEL
• DEODORIZING FILTER
• UNIT
• FILTER REPLACEMENT
TROUBLESHOOTING FOR CUSTOMER ASSISTANCE SPECIFICATIONS
.............................................
.............................................
...............................................
...............................
.................
............................
..........
....................................
...
E-10
E-11
E-16 E-19 E-21
E-2
E-4
E-6
E-8
Thank you for purchasing this SHARP Air Purifi er. Please read this manual carefully before using the air purifi er. After reading, keep the manual in a convenient location for future reference.
E-1
OM_KC-A60J_EN.indd Sec1:1OM_KC-A60J_EN.indd Sec1:1 11/26/12 10:28:50 AM11/26/12 10:28:50 AM
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed, including the following:
WARNING
Read all instructions before using the unit.
Use only a 220~240 volt outlet.
• Do not use the unit if the power cord or plug is damaged or the connection to the wall outlet is loosened.
• Periodically remove dust from the plug.
• Do not insert fi ngers or foreign objects into the air intake or air outlet.
• When removing the power plug, always hold the plug and never pull on the cord.
Electrical shock and/or fi re from a short circuit may result.
Be careful not to damage the power cord, it may cause electric shock, excess heat or fi res.
• Do not remove the plug when your hands are wet.
• Do not use this unit near gas appliances or fi replaces.
When refi lling the Water Tank, cleaning the unit, or when the unit is not in use, be sure to unplug the unit. Electrical shock and/or fi re from a short circuit may result.
• If the power cord is damaged, it must be replaced by the manufacturer, its service agent, a Sharp authorized Service Centre or similarly qualifi ed person in order to avoid a hazard.
Only a Sharp Authorized Service Centre should service this air purifi er. Contact the nearest Service
Centre for any problems, adjustments, or repairs.
Do not operate when using aerosol insecticides or in rooms where there is oily residue, incense,
sparks from lit cigarettes, chemical fumes in the air, or in locations where the unit may get wet, such as a bathroom.
Be cautious when cleaning the unit. Strong corrosive cleansers may damage the exterior.
• When carrying the unit, remove the Water Tank and Humidifying Tray fi rst and hold the unit by handles on both sides.
Do not drink the water in the Humidifying Tray or Water Tank.
Change the water in the Water Tank daily with fresh tap water and regularly clean the Water Tank
and Humidifying Tray. (See E-12 and E-13). When unit is not in use, dispose of the water in the Water Tank and Humidifying Tray. Leaving water in the Water Tank and/or Humidifying Tray may result in mold, bacteria, and bad odours.
In rare cases, this bacteria may cause harmful physical effects.
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure they do not play with the appliance.
– To reduce the risk of electrical shock, fi re or injury to persons:
NOTE
If this air purifier should cause interference to radio or television reception, try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation distance between the unit and radio/TV receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
– Radio or TV Interference
E-2
OM_KC-A60J_EN.indd Sec1:2OM_KC-A60J_EN.indd Sec1:2 11/26/12 10:28:50 AM11/26/12 10:28:50 AM
CAUTIONS CONCERNING OPERATION
Do not block the intake and/or air outlet.
Do not use the unit near or on hot objects, such as stoves or heaters, or where it may come into
contact with steam.
Always operate the unit in an upright position.
• Hold the unit by using the handles on both sides when moving. Do not move when the unit is in operation.
Do not move or change the direction of the main unit while dragging the casters.
Lift it up and move such as a tatami mat, a fl oor which gets damaged easily, an uneven place, and thick-poled carpet.
When moving by the caster, move it in a horizontal direction.
Turn the appliance off and remove the water tank before moving, take care not to catch your ngers.
• Do not operate the unit without the filters, Water Tank, and Humidifying Tray properly installed.
• Do not wash and reuse the HEPA fi lter.
Not only does it not improve fi lter performance, it may cause electric shock or malfunction.
• Clean the exterior with a soft cloth only.
Do not use volatile fl uids and/or detergents. The unit surface may be damaged or cracked. In addition, the sensors may malfunction as a result.
• Frequency of maintenance required (descaling) will depend on the hardness or the impurities of the water that you use; the harder the water the more often descaling will be necessary.
• Keep the unit away from water.
INSTALLATION GUIDELINES
• When using the unit, place at least 2m away from equipment utilizing electric waves such as televisions or radios to avoid electrical interference.
• Avoid a location where the sensor is exposed to direct wind.
The unit may not operate properly.
• Avoid use in locations where furniture, fabrics or other items may come in contact with and restrict the air intake and/or air outlet.
• Avoid use in locations where the unit is exposed to condensation or drastic temperature changes. Appropriate conditions are when room temperature is between 5 – 35 ºC.
• Place on a stable surface with suffi cient air circulation.
When placing the unit on a heavily carpeted area, the unit may vibrate slightly. Place the unit on an even surface to avoid water leakage from the Water Tank and/or Humidifying
Tray.
• Avoid locations where grease or oily smoke is generated.
The unit surface may crack or the sensor may malfunction as a result.
• Place the unit about 30 cm(1 ft) away from the wall in order to ensure proper airfl ow.
The wall directly behind the air outlet may become dirty over time. When using the unit for an
extended period of time in the same location, periodically clean the wall and protect the wall with a vinyl sheet, etc. to prevent the wall from becoming dirty.
FILTER GUIDELINES
Follow the instructions in this manual for correct care and maintenance of the fi lters.
E-3
OM_KC-A60J_EN.indd Sec1:3OM_KC-A60J_EN.indd Sec1:3 11/26/12 10:28:50 AM11/26/12 10:28:50 AM
PART NAMES
FRONT / BACK
1 2
3
1 Main Unit Display
2
Front Monitor
3
Main Unit
(Ref.E-5)
1
2
3 4
5
6 7
8
(Shape of plug depends on country.)
1 Air Outlet 6 Float 2 Handle 3 Sensor
•Dust Sensor
•Temperture / Humidity Sensor
•Odour Sensor
4 Water Tank 13 Power Cord / Plug 5 Humidifying Filter
(2 Locations) (Internal)
7 Humidifying Tray 8 Caster
9 HEPA Filter 10 Deodorizing Filter 11 Back Panel 12 Air Inlet
(4 Locations)
(white)
(Pre-Filter)
9
10
11 12
13
(black)
INCLUDED
• Operation manual
• Slipper
OM_KC-A60J_EN.indd Sec1:4OM_KC-A60J_EN.indd Sec1:4 11/26/12 10:28:50 AM11/26/12 10:28:50 AM
×4
E-4
MAIN UNIT DISPLAY
2
3
1
678
5
4
1 POWER ON Button
a CLEAN AIR MODE Button / INDICATOR LIGHT b CLEAN AIR & HUMIDIFY MODE Button / INDICATOR LIGHT c CLEAN ION SHOWER MODE Button / INDICATOR LIGHT
2 LIGHT CONTROL Button 5 CHILD-LOCK Button /
3 Plasmacluster Ion ON / OFF Button /
INDICATOR LIGHT
4 FILTER RESET Button /
INDICATOR LIGHT
(green)
(red)
a
b
6 Plasmacluster Sign
7 FAN SPEED Button /
8 POWER OFF Button
c
(green)
(green)
(green)
INDICATOR LIGHT
INDICATOR LIGHT
(green)
(green)
ILLUSTRATIVE DIAGRAM
Humidity Monitor
Indicates approximate humidity level in the room. Humidity setting cannot be adjusted.
Odour Monitor*
Indicates the odour intensity of the room in 3 stages colours.
green
red
Faint Strong
Dust Monitor
Indicates the air purity of the room
Humididify Light
green
off red
(Flash
ing)
Humidity ON
Humidity OFF
need to supply water
in 5 stages colours.
Clean
Impure
green
red
E-5
OM_KC-A60J_EN.indd Sec1:5OM_KC-A60J_EN.indd Sec1:5 11/26/12 10:28:51 AM11/26/12 10:28:51 AM
PREPARATION
FILTER INSTALLATION
Be sure to remove the power plug from the wall outlet.
Remove the Back Panel.
1
1
2
HEPA fi lter (White)
Remove the Filters from the
2
Install the Filters in the correct
3
Deodorizing fi lter (Black)
plastic bag.
order as shown.
Deodorizing fi lter (Black)
HEPA fi lter (White)
Click
Install the Back Panel.
4
Fill in the usage start date on the
5
Date Label.
E-6
OM_KC-A60J_EN.indd Sec1:6OM_KC-A60J_EN.indd Sec1:6 11/26/12 10:28:52 AM11/26/12 10:28:52 AM
Loading...
+ 16 hidden pages