GP2W0001YP
IrDA Data Sheet
FEATURES
• Built-in Photodiode
• Operating voltage 2.7 V to 5.5 V
• In circuit design, allow for the degradation of light
emitting diode output that results from long continuous operation (50% degradation/5 years).
• This product shall not contain the following materials, and these materials shall not be used in the production process for this product.
–CFCs
– Halon
– Carbon Tetrachloride
– 1.1.1. Trichloroethane (Methylchloroform)
– Specific brominated flame retardants such as the
PBBOs and PBBs are not used in this device.
INTRODUCTION
This specification applies to the outline and charac-
teristics of IrDA 1.2 type (data rate 2.4 kbps to
115.2 kbps, low power option compliant) optical data
communication transceiver.
115 kbps Transceiver
designed by considering 0.5 ms or more that is specified by IrDA. This turn around time means the time
that this device temporarily does not detect the
incoming signal, since the transmitted light from the
transmitter side reaches the detector side of the
same transceiver.
• Consider that 20 ms or more (at T
signal) is necessary to return from shut-down mode
to ready operation mode. In addition, thoroughly
confirm the operation in the actual application.
• When there is considerable external stray light or a
light source is located near the transceiver, or the
detector face receives considerable external stray
light, a pulse other than the desired signal output may
be generated as noise on the output terminal of the
transceiver. Consider the layout and structure in your
design to minimize disturbing light on the detector face.
• When the sensor is adopted in an IR communication
system, it should be used according to the signal
method specified by ‘Serial Infrared Physical Layer
Link Specification’ published by the Infrared Data
Association. Faulty operation may occur if a signal
method other than that specified is used.
= 25°C, no input
A
NOTES
• Caution should be taken to prevent the detector surface from being smeared with dust or dirt, or from
being touched, as it may cause faulty operation.
• Cleaning conditions:
– Solvent cleaning: Solvent temperature 45°C or
less. Immersion for 3 minutes or less.
– Ultrasonic cleaning: The effect of ultrasonic
cleaning on the device differs by cleaning bath
size, ultrasonic power output, cleaning time, PCB
size or device mounting condition, etc. Test the
device under actual conditions and confirm that
ultrasonic cleaning does not cause any immediate or potential defects.
– Cleaning solvent: The cleaning shall be carried
out with ethyl alcohol, methyl alcohol, or isopropyl
alcohol.
• In order to prevent electrostatic damage to the integrated circuit, handle this device in a static-free environment and workstation.
• External force applied to the device after mounting can
cause mounting defects such as the terminal coming
off. Be careful when handling the device and prevent
objects from touching the device after mounting.
• Refer to the ‘Precautions for Soldering’ section.
• When the system (program) is designed, the turn
around time from transmit to receive should be
1
2
LEDA
TXD3SD
R
2
RL
CX
TX
COMPONENTS
CX
1
CX
2
R
1
R
2
RL
(STANDARD)
RL
(LOW POWER)
NOTE: Choose the most suitable CX
the noise level and noise frequency of power supply.
4
RXD
2
SD
RXD
RECOMMENDED VALUES
47 µF/6.3 V (NOTE)
1500 pF/25 V
47 Ω ±5%, 1/10 W (NOTE)
1 kΩ ±5%, 1/10 W
2.2 Ω ±5%, 1/2 W
(V
= 3.0 V, IE = 40 mW/sr)
CC
33 Ω ±1%, 1/8 W
= 3.0 V, IE = 3.6 mW/Sr)
(V
CC
6
5
V
GND
CC
CX
1
+
R
1
V
CC
and R1 according to
1
GP2W0001YP-1
Figure 1. Recommended External Circuit
IrDA Data Sheet 1
GP2W0001YP 115 kbps Transceiver
R
1
CX
1
+
UART
SD INPUT PERFORMANCE
HIGH Normal Mode
LOW or
OPEN
Shutdown
Mode
1
ENCODER
2
CIRCUIT
4
5
DECODER
CIRCUIT
NOTES:
1 Transmitting data waveform
2
Encoder circuit output waveform
3 Transmitter output optical signal waveform
4 GP2W0001YP receiver output waveform
5
Receiving data waveform
Figure 2. System Example
CX
R
RL
V
2
CC
LEDA
3
TXD
2
GP2W0001YP
RXD
3
SD
GND
GP2W0001YP-2
2 IrDA Data Sheet
115 kbps Transceiver GP2W0001YP
0.9
0.7
P 1.4 x 5 = 7
1.7
1
2
3
4
5
6
LED Anode
Transmitter Data Input
Shutdown
Receiver Data Output
Ground
Supply Voltage
LEDA
PIN PIN NAME SYMBOL
TXD
SD
RXD
GND
V
CC
1
23456
0.9
0.7
P 1.4 x 5 = 7
1.7
NOTES: Dimensions are in mm.
GP2W0001YP-4
1
23456
Soldering paste area
View from parts side
LENS (PD/LED) SIDE
Solder Mask Opening
T
1
2
3
4
5
NOTES:
1 Transmitting data waveform
2
Encoder circuit output waveform
3 Transmitter output optical signal waveform
4 GP2W0001YP receiver output waveform
5
Receiving data waveform
T =
Data Rate
Data rate: 2.4 kbps, 9.6 kbps, 19.2 kbps, 38.4 kbps,
Figure 3. Signal Waveform Example
0
3T/16
0
1
57.6 kbps, 115.2 kbps
T
10 1
10 1
GP2W0001YP-3
Recommended Size of
Solder Cream Paste
Open the solder mask as shown in Figure 4. The size
of solder cream paste for this device before reflow soldering must be as large as the foot pattern landings.
Figure 4. Foot Pattern and
Solder Cream Paste Size
IrDA Data Sheet 3
GP2W0001YP 115 kbps Transceiver
8.7 ±0.2
3.15
3.5
1.7
0.6
2.95
CENTER
OF EMITTER
2
1
2.325
2.2
4.2
4.2
EMBOSSED
'S'
1.0
φ2.8
±0.1
CENTER
OF DETECTOR
φ3.6 ±0.1
6 - 1.1 ±0.2
0.7
0.7
P 1.4 x 5 = 7 ±0.2
4
3
6
5
+0.2
6 - 0.8
-0.3
0.7
0.7
P 1.4 x 5 = 7 ±0.2
NOTES:
1. Dimensions are in mm.
2. Unspecified tolerances are ±0.3 mm.
3. Adhesion of resin to the terminal area are allowed MAX. 0.3 mm.
4. Resin burr are not included in this outline drawing.
5. Product mass: Approx. 0.12 g
6. Mold resin: Epoxy resin (black)
area: Au plating
Figure 5. GP2W0001YP Outline Dimensions
PIN
1
2
3
4
5
6
PIN NAME SYMBOL
LED Anode
Transmitter data Input
Shutdown
Receiver Data Output
Ground
Supply Voltage
LEDA
TXD
SD
RXD
GND
V
CC
GP2W0001YP-5
4 IrDA Data Sheet
115 kbps Transceiver GP2W0001YP
RATINGS AND CHARACTERISTICS
Absolute Maximum Ratings
PARAMETER SYMBOL RATINGS UNIT NOTES
Supply voltage V
Forward current I
Peak forward current I
Operating temperature T
Storage temperature T
Soldering temperature T
NOTES:
1. Pulse width: 78.1 µs. Duty ratio: 3/16.
2. Soldering reflow time: 5 seconds.
CC
F
FM
OPR
STG
SOL
0 to 6.0 V
50 mA
500 mA 1
-10 to +70 °C
-20 to +85 °C
230 °C2
Recommended Operating Conditions
PARAMETER SYMBOL OPERATING CONDITION UNIT
Supply voltage V
CC
Data rate BR 2.4 to 115.2 kbps
Shutdown circuit high level input voltage V
Shutdown circuit low level input voltage V
Logic high transmitter input voltage* V
Logic low receiver input voltage* V
IHSD
ILSD
IHTXD
ILTXD
2.7 to 5.5 V
VCC – 0.6 to V
CC
0.0 to 0.4 or Open V
2.4 to V
CC
0.0 to 0.4 V
V
V
NOTES:
*Recommended circuit of emitter side.
IrDA Data Sheet 5