Sharp GP2U06 Datasheet

GP2U06 High Sensitivity Dust Sensor
Compact and Thin Type Dust Sensor for Detecting Particles
General Description
Sharp's GP2U06 is dust sensor which integrated optical sensor portion and signal amplifier portion. It is suitable for indoor air purifier sensor because of compact, thin, low dissipation current type.
Features
(1) Compact, thin type (58 x 38 x 25mm) (2) High sensitivity
3
)
(3) Can detect dust even in low density area
(Minimum particle density : TYP. 0.02mg/m3) (4) Operating voltage : 5V (5) Low dissipation current (Icc : MAX. 15mA)
Applications
(1) Air purifiers (2) Air conditioners
Outline Dimensions
Detecting window
φ9
58
Terminal configuration
GND
1
2 3 4
(Unit : mm)
φ3.2
38
Connector
25
Output terminal Emitting device operating terminal
Vcc
1 2
3 4
Absolute Maximum Ratings
Parameter Symbol Ratings Supply voltage -0.3 to +7 Input terminal voltage V Operating temperature ˚C Storage temperature
Vcc V
LED V
-0.3 to +Vcc
opr
T Tstg
-10 to +65
-20 to +80
Unit
˚C
(Ta=25˚C)
Remarks
-
Open drain input
-
-
Operating supply voltage
Symbol Ratings
5±0.5
(Notice) • In the absence of device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP device shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
• Specifications are subject to change without notice for improvement. (Internet) • Data for SHARP's optoelectronic/power device is provided on internet. (Address http://www.sharp.co.jp/ecg/)
Unit
VVcc
Remarks
-
Tec.U970502
GP2U06
High Sensitivity Dust Sensor
Electro-optical Characteristics
Parameter Symbol
Detecting sensitivity Output voltage (no dust) Range of output voltage V LED operating current mA Dissipation current mA
*1 • Dust density is measured by mildseven smoke density, using digital dust meter [P-5L2 made by SHIBATA scientific instrumental industry].
• Detecting sensitivity is settled according to the change of output voltage when dust density change
0.1mg/m *2 Input conditions to LED terminal (pulse operation condition) is shown in the right figure.
3
from the initial value.
V
I
K
LED
I
CC
OC OH
Conditions MIN. TYP. MAX. Unit
*1, 2 *2
RL=4.7k
LED terminal=0V *2 RL= *2
0
3.2
-
-
(Ta=25˚C, Vcc=5V)
0.50.35 0.65
0.5
1.0
-
15 10
-
20 15
V/(0.1mg/m
V V
Block Diagram
Detecting window
Dust
Emitting circuit
Photodiode circuit
Operation circuit
Amp. Amp.
Peak hold
circuit
Sensitivity adjustment
Input condition to LED terminal
3
)
Vcc
R1
Tr
+
C1
LED
R2
GP2U06
Recommended input conditions to LED terminal
T=30±5ms PW=0.4±0.1ms
4
Vcc Emitting device
3
Operating terminal
Output terminal(Vo)
2
1
GND
T=30ms
Pw=0.4ms
R3
R4
2
As of May 1997
Tec.U970502