Sharp GP2U05 Datasheet

GP2U05
GP2U05
Particulate Detectable High Sensitivity Type Dust Sensor
Features
1.
High sensitivity (Dust detection sensitivity : 1 V/(0.1 mg/m )
2. Particulates of low concentration can be detected. Lowest detectable dust concentration : TYP. 0.05 mg/m
Applications
1. Air cleaners
2. Air conditioners
Absolute Maximum Ratings
Parameter Symbol Rating Unit Supply voltage Input terminal voltage Operating temperature Storage temperature
- 0.3to+15
V
CC
V
- 0.3to+15
LED
- 10to+65
T
opr
T
- 20to+80
stg
V
Open drain operation input
V ˚C ˚C
3
3
Outline Dimensions
2-φ 3.2 ± 0.1 hole
2-8
2-R4
φ
10
(Dust passing hole)
65± 0.2
* Unspecified tolerance : ± 0.3 mm
(Ta=25˚C)
Remarks
-
-
-
2-R3
48
11
2-24
29 4
73.2
Hole for sensitivity adjustment VR
JAPAN SOLDERLESS TERMINAL MSG. CO. made connector (S5B-PH-SM)
31.2
2-2
Terminal connection
1 Frame GND 2 Output terminal(Vo) 3 Signal GND 4 LED drive terminal 5 V
CC
(Unit : mm)
1 2 3 4 5
Operating Supply Voltage
Symbol Rating Unit
12 ±1.8
CC
Electro-optical Characteristics
VV
Parameter Symbol Conditions MIN. TYP. MAX. Unit Detection sensitivity Output voltage at no dust Output voltage range LED drive current - mA Dissipation current - mA
*1 • Dust concentration shall be a value of the cigarette (MILD SEVEN) smoke concentration measured using the digital dust densitometer
(SHIBATA KAGAKU KOGYO CO. LTD. made P-5L2).
• Detection sensitivity K represents the change of output voltage when dust concentration changes by 0.1 mg/m .
*2 Input conditions (pulse drive conditions) to LED input terminal shall be as shown in the right drawing.
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.
*1 *2
K
*2
V
OC
VOHRL=4.7k ­I
LED terminal=0V,*2
LED
RL=
*2
I
CC
Remarks
-
0.7
0.1
Vcc- 1.8
1.0
1.0
15 12
(Ta=25 ˚C,Vcc=5V)
1.3
3.0
­20 20
V/(0.1mg/m
3
3
) V V
Vcc
R
1
Tr
+
C1
LED
R2
GP2U05
T=30ms
Pw=0.4ms
R3
R4
4
Internal Block Diagram
Detection window
Emitter
circuit
Drive
circuit
5
Vcc
4
LED drive terminal
3
Signal GND
GP2U05
Detector
circuit
Dust
(Note) Signal GND : GND of circuit system
Frame GND : Connect to the case (conductive resin). The signal GND is not connected to the frame GND in the case
Amp.
circuit
Sensitivity adjustment
Peak hold
circuit
Amp.
circuit
Output terminal (Vo)
2
1
Frame GND
Fig. 1 Output Voltage vs. Dust Concentration Fig. 2 Output Voltage vs. Supply Voltage
12
10
8
O
6
4
Output voltage V (V)
2
0 0.2 0.4 0.6 0.8 1.0
Conditions : Per Electro-optical Characteristics
Dust concentration (mg/m )
3
4.5
4
3.5
O
3
2.5
1.5
Output voltage V (V)
1
0.5
State with reflective object inserted from sensor outside and output voltage set to Vo=3.5V (at Vcc=12V)(equivalent to dust concentration of about 0.24 mg/m
10 11 12 13
Supply voltage Vcc (V)
No-dust state
14 15
3
)
Fig. 3 Output Voltage vs. Ambient Temperature
3.5
3
O
2.5
1.5
1
Output voltage V (V)
0.5
State with reflective object inserted from sensor outside and output voltage set to Vo=3.6V (at Ta=25˚C)(equivalent to dust concentration of about 0.22 mg/m
No-dust state
- 10 0 10 20 30 40 50 60
3
)
Ambient temperature Ta (˚C)
Loading...