SHARP DTE382 Technical Report

Date : Jun. 3,1998
DUPLICATOR: SD-2260
1. Change of vendor maker (for better productivity)
2. Addition of tapped hole on the AC power PWB installing plate
1. Change of vendor maker (for better productivity)
1. Model Name: SD-2060/3062/2260/2275
No. : DTE-382
part code is also changed. For the part name and part code, refer to the parts list.
3. Action: From the middle of production in June, 1998 (Running change)
2. Addition of tapped hole on the AC power PWB installing plate
1. Model Name: SD-2260/2275
2. General: As the 3P terminal block is changed on another model, M3 tapped hole is added on the plate
which installs the AC power PWB. On the above models, both AC power PWB installing plates can be commonly used.
3. Action: From the 1st unit of production in June, 1998
SHARP CORPORATION Reprography Division
1/2
Green
C
Ref.
Model
No.
name
SD-2060
SD-3062
SD-2260
SD-2275
SD-2060
SD-3062
SD-2260
SD-2275
1
SD-2060
SD-3062
SD-2260
SD-2275
SD-2060
SD-3062
SD-2260
SD-2275
SD-2060
SD-3062
SD-2260
2
SD-2275
<Interchange>
1. Interchangeable. 4. Not interchangeable.
2. Current type can be used in place of new type. New type cannot be used in place of current type.
3. Current type cannot be used in place of new type. New type can be used in place of current type.
Parts marked with " " is important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the safety and performance of the set.
Version P/G No.
15 - 33
16 - 33
15 - 107
16 - 107
15 - 106
ALL
16 - 106
15 - 105
16 - 105
15 - 3
46 - 13
Current parts New parts
Parts code Parts code
NROLR0949FCZZ NROLR0949FCZ1 AY
NROLR0965FCZZ NROLR0965FCZ1
NROLR0950FCZZ NROLR0950FCZ1
NROLR1165FCZZ NROLR1165FCZ1
NROLR0969FCZZ NROLR0969FCZ1 AU
NROLR0968FCZZ NROLR0968FCZ1 AV
LPLTM5140FCZ3 LPLTM5140FCZ4 AY
5. Interchangeable if replaced with same types of related
6. Others.
Price
rank
AV
parts in use.
Parts name
Transport
Roller 1 lower
Transport
Roller 3
Transport
Roller 2
Transport
Roller 7
Transport
Roller 6
AC Power Supply PWB Fixing Plate
Effec-
tive
time
Mid-
’98/6
1st lot
’98/6
Inter-
change-
ability
Note
1