SHARP DTE371 Technical Report

Date: Apr. 27, 1998
DUPLICATOR SD-4085
Changes of high-voltage transformer PWB
1. Model Name: SD-4085
2. General: The high-voltage transformer PWB is changed by the following reasons.
(1) In order to improve the workability, the shape of BC/BS check pins is changed, and the
No. : DTE-371
through hole on the PWB is filled. (2) In order to improve the productivity, the shape of PWB is partly changed. (3) Since the "C2-00" trouble detection is too sensitive, the capacity of capacitor (C106) is changed to increase the detection time.
SHARP CORPORATION Reprography Division
1/2
Green
C
<Part Name> <Old> <New>
High-voltage transformer PWB RTRNP0520FCZZ RTRNP0520FCZ1
For the above-mentioned item (1), the check pin protection sheet is supplied as a part for market action.
<Part Name> <Part code> <Attaching reference>
Check pin protection sheet PSHEP4512FCZZ
3. Action: After the stock of the old part is disposed (running change)
Ref.
Model
No.
name
SD-4085
<Interchange>
1. Interchangeable. 4. Not interchangeable.
2. Current type can be used in place of new type. New type cannot be used in place of current type.
3. Current type cannot be used in place of new type. New type can be used in place of current type.
Parts marked with " " is important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the safety and performance of the set.
Version P/G No.
33 -45 RTRNP0520FCZZ
All
33 -
Current parts
Parts code
New parts
Parts code
RTRNP0520FCZ1
PSHEP4512FCZZ
5. Interchangeable if replaced with same types of related parts in use.
6. Others.
Price
rank
CL
AD
Parts name
High-voltage
transformer
PWB
Check pin
protection sheet
Effec-
tive
time
Refer to
the
above
- 6
Inter-
change-
ability
1
Note
2/2
Loading...