Date: Jan. 28, 1998
DUPLICATOR SD-4085
No. : DTE-347
Skipping of parts setting in the technical report (DTE-302)
1. Model Name: SD-4085
2. General: Technical report already issued. Since two kinds of parts are skipped in "MEASURE TO
ALLEVIATE PROBLEMS OF IMAGE MISALIGNMENT AND TEARING OF THE GLASS
MYLAR IN THE RDH.", please add the following.
<Part name> <Part code> <Quantity>
Parallel φ 3 × 12
LPiNS0096FCZZ 4 pcs
E7 XRESP70-08000 4 pcs
Ref.
Model
No.
name
1 SD-4085
<Interchange>
1. Interchangeable. 4. Not interchangeable.
2. Current type can be used in place of new type.
New type cannot be used in place of current type.
3. Current type cannot be used in place of new type.
New type can be used in place of current type.
Parts marked with " " is important for maintaining the safety of the set. Be sure to replace these parts with specified ones
for maintaining the safety and performance of the set.
Version P/G No.
55
ALL
56
Current parts New parts
Parts code Parts code
- LPiNS0096FCZZ AB Parallel φ 3 × 12
XRESP70-08000
Quantity change
(16 → 20)
5. Interchangeable if replaced with same types of related
6. Others.
Price
rank
AA E7
parts in use.
Parts name
Effec-
tive
time
1st lot
’97/4
change-
Inter-
ability
6
Note
Quantity
4
SHARP CORPORATION Reprography Division
Green
C