SHARP DTE328 Technical Report

DUPLICATOR : SD-2260
Date
:
Oct. 20, 1997
1. ADDITION OF AN OZONE FILTER CARRIED OUT IN THE CENTER TRAY UNIT.
2. ADDITION OF BELT RIBS CARRIED OUT IN THE CENTER TRAY UNIT.
3. CHANGE CARRIED OUT IN THE SHAPE OF THE JOINT SEAL IN THE DV UNIT.
No. : DTE-328
1. Addition of an ozone filter carried out in the center tray unit.
1.Model Name: SD-2260
2.General: The addition of an ozone filter has been carried out in the suction section. This action
has been carried out as a measure to establish the standardization of parts with other machine types. In accordance with this change, a change in the shape of the suction frame has also been carried out (the addition of filter positioning ribs has been carried out), with both changes being carried out at the same time.
3.Description: a. Points of change in the suction frame.
Suction ozone filter (Newly added)
Added suction frame rib
LFRM-0760FCZ1
LFRM-0760FCZ2
SHARP CORPORATION Reprography Division
1/3
Green
C
b. Points of change in the suction ozone filter.
Figure of the inner section
Old filters: used in 2 locations
New filters: this filter has been discontinued.
4.Action: From the 1st lot of 1997 September production.
2. Addition of belt ribs carried out in the center tray unit.
1.Model Name: SD-2260
2.General: The addition of a belt rib sheet has been carried out to the suction duct upper in the
center tray unit, and a change has been carried out to the shape of the up/down of the paper feeding belt. This action has been carried out due to a patent return of another company. Added suction belt rib sheet: PSHEZ3507FCZZ.
Suction belt rib sheet (PSHEZ3507FCZZ)
Standard
Standard
Standard
3.Action: From the 1st lot of 1997 September production.
2/3
Suction belt rib sheet (PSHEZ3507FCZZ)
Suction duct upper sheet (PSHEP3506FCZZ)
Suction duct upper (PDUC-0079FCZZ)
3. Change carried out in the shape of the joint seal in the DV unit.
1.Model Name: SD-2260
2.General: There was a possibility of toner being scattered from the connection section between
the toner box unit and the DV unit. As a measure to alleviate this problem, a change in the shape of the joint seal has been carried out.
Square hole.
The present dimensions of 10 mm has been changed to 11 mm.
3.Action: From the 1st lot of 1997 September production.
Ref.
Model
No.
1
SD-2260 All
2 31 ---- PSHEZ3507FCZZ
3
<Interchange>
1. Interchangeable. 4. Not interchangeable.
2. Current type can be used in place of new type.
3. Current type cannot be used in place of new type.
Parts marked with ‘ ’’ is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
Version P/G No.
name
29 -38 LFRM-0760FCZ1 LFRM-0760FCZ2 AZ Suction frame
29 ---- PFILZ0266FCZZ AQ Suction frame ozon filter
35 -11 PFILZ0250FCZ1 PFILZ0250FCZ2 AY Suction ozone filter
15 -2
New type cannot be used in place of current type.
New type can be used in place of current type.
Current parts New parts
Parts code Parts code
PSEL-0738FCZ1 PSEL-0738FCZ2 Joint seal 3
Price
rank
AK
5. Interchangeable if replaced with same types of related parts in use.
6. Others.
Parts name
Belt sheet 6 Q’ty: 2
Effec-
tive
time
1st lot
’97/9
Inter-
change-
ability
5
Note
3/3