SHARP DTE325 Technical Report

DUPLICATOR : SD-4085
Date
:
Nov. 6, 1997
No. : DTE-325
REGARDING OPD6 JAMS THAT OCCUR IN THE RDH UNIT.
1.Model Name: SD-4085
2.General: When paper that is not stiff, such as paper that has not been copied, paper with ragged
edges, cotton paper, etc., is used, the original may fail to reverse in the RDH’s first internal reversal section. When this happens, what is known as an OPD6 JAM (jammed paper) may occur. The following countermeasure will prevent this.
3.Description: With your finger, adjust both edges of the exposure paper guide B (P/G No. 55-37),
located in the RDH exposure frame unit, to a height of 12 mm.
View from the bottom
Scale
Contact surface for the scale
Exposure paper guide B PGIDH1682FCZ1
SHARP CORPORATION Reprography Division
Green
C