SHARP DTE308 Technical Report

DUPLICATOR : SD-4085
Date
:
Jul. 1, 1997
1. MEASURE TO PREVENT THE PAPER DELIVERY PLATE MYLAR FROM PEELING, AND MEASURE TO IMPROVE THE EFFECTIVENESS OF THE STATIC ELECTRICITY DISCHARGE PERFORMANCE.
2. CHANGE IN THE SHAPE OF THE OZONE FILTER OF THE FUSING UPPER CARRIED OUT AS A MEASURE
TO IMPROVE OPERATIONABILITY.
3. MEASURE TO IMPROVE PROBLEMS OF IMAGE MISALIGNMENT IN THE RDH.
4. MEASURE TO IMPROVE PROBLEMS OF UNEVENNESS DURING HALF-TONE COPIES.
No. : DTE-308
1. Measure to prevent the paper delivery plate mylar from peeling, and measure to improve the effectiveness of the static electricity discharge performance.
2.General: The changes described below have been carried out as a measure to improve the
performance of the duplex tray unit.
3.Description: 1) There was a danger of the paper delivery plate mylar peeling during operations of the
one-cycle detection lever. As a measure to alleviate this problem, a change has been carried out in the paper delivery plate mylar used in the AB series.
2) A change in the width of the double-side tape has been carried out as a measure to improve the effectiveness of the static electricity discharge performance. The width of the double-side tape has been changed from 8 mm to 6 mm.
Paper delivery plate mylar
4.Action: 1) From the start of 1997 March production.
2) From the start of 1997 February production.
SHARP CORPORATION Reprography Division
1/4
Green
C
2. Change in the shape of the ozone filter of the fusing upper carried out as a measure to improve operationability.
1.Model Name: SD-4085
2.General: A change in the shape of the filter used in the ozone duct attached to the fusing upper
side on the rear frame side has been carried out as indicated in the figure shown to the right. This change has been carried out as a measure to improve operationability during assembly operations.
(Changed) Molt (the thickness has been changed from 3mm to 2mm)
3.Action: From the start of 1997 April production.
3. Measure to improve problems of image misaligment in the RDH.
1.Model Name: SD-4085
2.General: A reinforcement plate has been added to the inner side of the exposure motor
attachment plate. This change has been carried out as a measure to alleviate problems of image misalignment in the RDH.
Exposure motor reinforcement plate LPLTM5371FCZZ
Exposure motor attachment plate LPLTM5175FCZZ P/G 56 -48
Ì
RMOTP0795FCZZ RDH Main motor 1 attached together with M4 ×1!
3.Action: From the start of 1997 April production.