Date: Jul. 8, 1994
DUPLICATOR : SD-2060
No. : DTE-170
1. CHANGES TO THE FUSING DRIVE UNIT TO PREVENT
COPY MI SAL IG N MENTS
2. JAM INDICATION IN THE RADF REVERSAL SECTION
1. Changes to the fusing drive unit to prevent copy misalignments
1.Model name: SD-2060, 3062
2.General: We have changed and added parts inside the fusing drive unit to prevent copy
misalignments.
3.Description:
NGERH0995FCZZ (Changed)
11
PSPAZ0095ECZZ (Added)
7
NSFTZ1880FCZ1 (Changed)
1
E7
2
LPINS0096FCZZ
10
NSFTZ1881FCZ1
1
E7
2
Milling face
E6
9
MSPRC2231FCZZ (Added)
6
E7
12
PCLR-0387FCZZ (Added)
5
LX-WZ0256FCZZ (Added)
4
LPLTM4459FCZZ (Added)
3
8
PSPAZ0095FCZZ (Added)
7
MSPRC2231FCZZ (Added)
6
PCLR-0387FCZZ (Added)
5
LX-WZ0256FCZZ (Added)
4
LPLTM4459FCZZ (Added)
3
CCLR-0060FC31 (Added)
Milling face Numbers before the parts code indicate the order to mount.
E7
9
8
4.Action: From the first unit of April 1994 production.
SHARP CORPORATION Reprography Division
1/3
Green
C
2. JAM indication in the RADF reversal section
1.Model name: SD-2060
2.General: Messages like “JAM” or “ADF is broken.” appeared however no paper jams occurred in
RADF. We changed as follows to prevent this.
<Cause>
When light from outside (direct sunlight) came into the RDD sensor section because of
where the machine was equipped, the RDD sensor erroneous detection occurred and
sensor indicated these error messages.
3.Description: We add the shut out mylar 1 and 2 that shut out direct light from the sensor section to
prevent the erroneous detection.
Standard position
of the sensor end
Shut out mylar 1
Guide
1
3
Sensor
Shut out mylar 2
4.Action: From mid-May 1994 production.
RDD sensor
Guide
Guide
2/3