1. PREVENTION OF SOLENOID COIL DAMAGE
2. CHANGES TO MEET SAFETY ST ANDARD REQUIREMENTS
FOR THE COOLING FAN MOTOR
3. ADDITION OF RACK COVER TO RIB
1. Prevention of solenoid coil damage
1.Model name: SD-2060, 3062
2.General: The solenoid mounting method has been changed to prevent damage to the coil’s
protective tape. The coil was found to come in contact with the suction solenoid
mounting board, in the air paper feeder of the 1000 tray unit.
3.Description: The mounting direction of the solenoid has been changed as shown in the illustration
below. The harness has also been changed in accordance with the above .
(Current) (New)
Solenoid harness
Paper feeding solenoid
Paper feeding solenoid B
RPLU-0292FCZZ
Harness from solenoid
(Red, Purple)
Harness (Gray)
4.Action: From April 1994 production.
SHARP CORPORATION Reprography Division
1/3
Green
C
2. Changes to meet safety standard requirements for the cooling fan motor
1.Model name: SD-2060, 3062
2.General: Changes have been made to display the UL/CSA mark on the cooling fan motor. This is
in accordance with safety standard requirements.
3.Description:
Current New
Steel plate
Connector
4.Action: From April 1994 production.
3. Addition of rib to rack cover
1.Model name: SD-2060, 3062
2.General: The rack in the lower section of the size guide was found to exert external pressure, in
the manual tray unit. This caused the rack and pinion to loosen. A manual block was
mounted to the rack to prevent it from exerting pressure. The manual block has now
been discontinued. A rib has been added to the rack cover to improve productivity.
3.Description:
Manual tray 1
Discontinued manual block
due to addition of rib
Manual rack D7
Manual spacer
Manual block
Manual rack D7
Current New
Rack cover
4.Action: From Mid-April 1994 production.