SHARP DTE146 Technical Report

Date: Apr. 4, 1994
DUPLICATOR: SD-3062
No. : DTE-146
CHANGE IN UDH UNIT PARTS (THIS CHANGE HAS BEEN CARRIED OUT FROM THE START OF MASS PRODUCTION).
1.General: The parts changes and additions described below have been carried out on the UDH
unit of model SD-3062 as of the start of mass production, and are hereby reported.
2.Description: 1. PWB protective mylar sheet has been added between UDH delivery motor 2 and the sidewise paper size switch attachment plate, and a conductive sheet has been added to the sidewise paper size switch attachment plate.
From the first lot production.
UDH Delivery motor 2
Added PWB protective mylar sheet
Sidewise paper size switch attachment plate
Added conductive sheet
2. The attachment screws of the delivery opening PGU AS have been changed to prevent loosening of the screws.
From 1994 January production.
SHARP CORPORATION Reprography Division
1/3
Green
C
3. The attachment screws of the grounding terminal have been changed to prevent the tips of the screws from coming in contact with the solenoid coil protective cover of the stacking gate in the separator duct unit.
Change in screw length M3 x 8 M3 x 6
From 1994 January production.
4. A movement sheet has been added between the movement paper guide upper AS and the movement drive shaft to prevent abnormal noise (creaking).
2/3
Added movement sheet
From 1994 January production.