SHARP DTE145 Technical Report

Date: Mar. 29, 1994
DUPLICATOR : SD-3062
1.CENTER TRAY DOUBLE FEED TROUBLE SHOOTING.
2.PARTS GUIDE CORRECTIONS.
Model name: SD-3062 / 2060
1. Center tray double feed trouble shooting.
1.General: The paper separation capacity is weakened by escaping air in the center tray unit, sometimes causing double feeding. To alleviate the problem of escaping air molts have been added to the front and rear delivery plates.
No. : DTE-145
2.Description: Delivery molts have been added to the under side of the front and rear delivery plates.
Added: delivery molts
(PMLT-0929FCZZ)
Added: delivery molt
(PMLT-0929FCZZ)
Note: The change described above has been carried out in machines bound for the
United Kingdom from the start of mass production of model SD-2060.
3.Action: (Factory action)
From 1994 Mid January production.
SHARP CORPORATION Reprography Division
1/3
Green
C
2. Parts guide corrections.
1.General: The toner case unit has been discontinued in model SD - 3062 since the start of mass production and is hereby reported. Note: the bottle guide is also in use in model SD - 2060, and this change has been carried out by way of running change starting in 1993 December production.
2.Description: The parts changes and additions have been carried out as shown in the figure below.
Area shaded by the diagonal lines.
Micro Switch V-152-3C25 (added) QSW-M0319FCZZ
Micro switch (changed)
• 100V series: Switch section is colored black (QSW-M0453FCZZ)
• 200V series: Switch section is colored red (QSW-M0406FCZZ)
Changed hole position
Bottle guide (change in shape) PG: DM1440FCZ1 (Interchangeable for models SD-3062 / 2060)
Door SW lever (added) MLEVF0209FCZZ
Standard
Standard
Switch mylar (added) PSHEP3626FCZZ
2/3
3.Action:
Inter lock SW cover PCOVP1194FCZZ
The parts within the line are used in model SD-3062.
M3 x 40 3-point screws XBPSD30P40KS0
(Factory action)
SD-3062: Since the first production unit. SD-2060 (Bottle guide): Running change from 1993 December production.
Loading...