SHARP DTE127 Technical Report

Date: Feb. 8, 1994
DUPLICATOR : SD-2060
[Service information]
No. : DTE-127
MIRROR MOTOR REPLACEMENT SEQUENCE.
1.General: The sequence for replacement of the mirror motor in model SD-2060 is not recorded in
the service manual, and is therefore described below .
2.Description: Mirror motor replacement procedure sequence.
1. Remove the upper left cabinet and the back cabinet (12 screws).
2. Disengage and remove the cooling fan attachment plate unit (4 screws). (It is also possible to perform the operation through the holes in the A section of the figure below. In this case, it is not necessary to disengage and remove the attachment plate unit of the cooling fan.)
3. Loosen the set screws of the winding coupling area on the mirror motor side of the unit.
4. Remove the mirror motor (4 screws).
5. Replace the mirror motor.
6. Install the new mirror motor by following this procedure in reverse sequence.
Caution: If the winding drive shaft remaining in the machine is moved toward the rear
once the mirror motor is disengaged and removed, the shaft socket in the front of the machine becomes disengaged.
SHARP CORPORATION Reprography Division
1/2
Green
C
When loosening the set screws, first loosen and , and afterwards and ➃. When tightening the set screws, first tighten and , and afterwards and ➂.
1
2
3
4
Winding coupling
Section A
Front side
Winding coupling
Winding drive shaft
Rear side
Mirror motor
2/2