Date: Nov. 18, 1993
DUPLICATOR : SD-3076
[Service information]
No. : DTE-101
OPTIONAL DEPARTMENT COUNTER
EA11, EA12 CONNECTION.
1.Model name: SD-3076, 3075
2.General: It has become possible to attach the external department count er (SF-EA11 and EA12)
to the above models. The installation procedure and necessary serv ice parts are
available with the service parts.
3.Description: (Counter installation procedure)
* (Counter installing position)
Turn off the power source of the copier, then follow the procedure below:
(1)Cut out the notch of the upper right cabinet.
Loosen a screw which is fixing the right cabinet, and open the right cabinet.
Then cut out the notch of the upper right cabinet
(2)Connect the counter connecting harness to the copier body.
Pass the counter connecting harness (DHAI-2092FCZZ) as shown in the figure, and
connect the connector (black) of the counter connecting harness with the connector
(black) of the copier body.
SHARP CORPORATION Reprography Division
1/3
Green
C

(1)Fix the counter connecting harness.
Insert the snap band attached tot he counter connecting harness into the plate attached
to the back surface of the upper right cabinet, and fix it.
At this time, engage the counter connecting harness to t he notch section of the upper
right cabinet.
2/3
(4)Attach the counter attachment base (CPLTZ4185FC01) to the copier body.
Clean the attachment section (cabinet) of the counter attachment base wit h alcohol ,
remove the seal from the back surface of the counter attachment base, and attach the
counter attachment base as shown in the figure.

(5)Connect the counter and the counter connecting harness.
Connect the connector (white) the counter and the connector (white) of the counter
connecting harness.
(6)Attach the counter to the counter attachment base.
Clean the back surface of the counter with alcohol. Remove the seal from the top
surface of the counter attachment base. Put the counter harness and the counter
connecting harness in the grooves of the counter attachment base as shown in the
figure. Then attach the counter to the counter attachment base.
(7)Close the right cabinet, and tighten it with a fixing screw.
Supply power to the copier body. Then perform counter setting according to “Counter
Setting” in the Service Manual. (SF-EA11) (SF-EA12)
No. Parts code Price rank Parts name
1. DHAI-2092FCZZ AQ Counter connecting harness
2. CPLTZ4185FC01 AW Counter attachment base
3/3