Date: Jun. 23, 1993
DUPLICATOR : SD-3076
1. RELEASE OF THE HIGH ALTITUDE USE OSCILLATOR ELEMENT AS A SERVICE PARTS
2. DISCONTINUED USE OF THE MYLAR SHEET OWING TO A CHANG E IN THE PROCESS
CONTROL SENSOR
3. PARTS GUIDE CORRECTION
4. CHANGE IN THE RDH FRONT CABINET AND TOP RIGHT CABINET HOLDING SCREWS TO
AVOID STRIPPING OF PLATING
5. CHANGE IN THE RDH BALANCERS FOR PRODUCTIVITY ENHANCEMENT
No. : DTE-088
1. Release of the high altitude use oscillator element as a service parts
1.Model name: SD-3075 / 3076 / 2075
2.General: As the board incorporating the oscillator element for a high altitude area is in supply as
the vacuum control board, the oscillator element for the high altitude area is now
available as a service parts.
3.Description:
Parts name Parts code Price rank
Oscillator element for the high altitude area (CSA330MG102) 0DM3S21168/// AT
4.Action: Available as a service parts only.
2. Discontinued use of the mylar sheet owing to a change in the process control sensor
1.Model name: SD-3075 / 3076
2.General: Tow sensor mylar sheets attached to the process control sensor are now discontinued
to use after a structural change in the sensor.
3.Description: The mylar sheets being used now are replaced by implementation of ribs. The use of
the mylar sheets are discontinued after the change.
SHARP CORPORATION Reprography Division
1/5
Green
C
(Current) (New)
Sensor mylar sheets attached
PSHEP3234FCZZ
Ribs added after the structural change.
4.Action: (Factory action)
From May 1993.
3. Parts guide correction
1.Model name: SD-3075 / 3076
2.General: Please note change in the SD-3075 and SD-3076 Parts Guide for design change
since the first production unit. This has to be corrected in your Parts Guide.
3.Description: Correction in parts guide description
Correction is need for the fan quelling mylar sheet-2 shown in Parts Guide No. 30 -91
that it is only for the export version AB series machine.
30 -91 0IA42341-01A/ AM EG Fan quelling mylar sheet-2
30 -91 0IA42341-01A/ AM EG
Fan quelling mylar sheet-2
(Export —- AB series)
Sevice Hint
Apart from this, it could prevent a paper misfeed for the double-sided tray by adding
the fan quelling mylar sheet to the inch version SD-2075, same as SD-3075.
2/5