Date: Sep. 4, 1996
COLOR IMAGE SCANNER: JX-250
No. : CX-214
(Service Information)
ESTABLISHMENT OF PARTS CODES FOR SERVICE TOOLS.
1.Model Name: JX-250/M/P
2.General: The parts codes for the service tools of the JX-250 series have been established and
are hereby reported.
3.Description:
No. Service tool Parts code Note
➀ Optical adjustment stage UKOG-7025XCZZ
➁
Adjustment extension cable
UKOGK7026XCZZ
➂ UKOGK7027XCZZ
➃
Optical adjustment control unit
UKOG-7028XCZZ
➄ UKOG-7029XCZZ
For the old CCD PWB (The CCD direct
cable has been lengthened 15 pins.)
For the new CCD PWB (The CCD direct
cable has been lengthened 11 pins.)
A 15-pin CCD connector control circuit
board and 100V electrical supply unit.
A 15-pin CCD connector control circuit
board and 200V electrical supply unit.
➅ Optional checker UKOG-7030XCZZ
➆ Adjustment angle UKOG-7031XCZZ
➇ Adjustment spacer UKOG-7032XCZZ
SHARP CORPORATION Printer and Scanner Division
1/2
Orange
C
Ref.
Model
No.
name
JX-250/M/P All — —
<Interchange>
1. I nt er changeab l e. 4. N ot i n te r c ha ng ea bl e.
2. C urr e nt t y pe c a n be u s ed i n p la ce of new ty pe .
New ty pe cann ot be us ed i n place of curr ent type .
3. C urre nt ty pe cann ot be used i n place of new ty pe.
New t y pe c a n be u sed in pla c e of c u rr en t ty p e.
Parts marked with “ ” is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
Version P/G No.
!
Current parts New parts
Parts code Parts code
UKOG-7025XCZZ DU Optical adjustment stage
UKOGK7026XCZZ
UKOGK7027XCZZ
UKOG-7028XCZZ
UKOG-7029XCZZ ➄
UKOG-7030XCZZ CG Optional checker ➅
UKOG-7031XCZZ AZ Adjustment angle ➆
UKOG-7032XCZZ BC Adjustment spacer ➇
5. Interchangeable if replaced with same types of
6. Others.
Price
rank
Adjustment extension cable
(For the old CCD PWB)
BA
Adjustment extension cable
(For the new CCD PWB)
CE Optical adjustment control unit
related parts in use.
Parts name
Effec-
tive
time
Inter-
change-
ability
6
Note
➀
➁
➂
➃
2/2