Date : |
Aug. 3, 1995 |
|
COLOR IMAGE SCANNER: JX-AF3 |
No. : |
CX-200 |
|
|
[Concerning part changes] |
||
|
|
|
|
|
|
THE ADDITION OF CORE SCREWS TO |
|
|
|
THE ADF RELAY PWB |
|
1.Model Name: |
|
|
|
JX-AF3 |
|||
2.General: |
In accordance with F-mark codes, core screws are being added to the ADF relay PWB |
||
|
of the 200 volt model listed above. |
3.Description: Core screws will be added to the ADF relay PWB as shown in the figure below.
(1)Core screw RCORF5013BCZZ will be added between SW2 CN1's12 pin and CN3's 5 pin.
(2)Core screw RCORF5013BCZZ will be added between SW3 CN1's13 pin and CN3's 2 pin.
(3)Core screws RCILZ7020SCZZ will be added between M+24V CN1's 3 and 16 pins and CN3's 10 pin.
(3) Additional core screw,
RCILZ7020SCZZ
(2) Additional core screw, |
(1) Additional core screw, |
RCORF5013BCZZ |
RCORF5013BCZZ |
1/2
SHARP CORPORATION Printer and Scanner Division
Orange
C
(3)Additional core screws RCILZ7020SCZZ
Pattern cut
(1), (2) Additional core |
Pattern cut |
screws, RCORF5013BCZZ |
|
4.Action: From June, 1995 production on.
Ref. |
Model |
|
|
|
|
Current parts |
|
New parts |
|
|
Effec- |
Inter- |
|
|
|
|
|
|
|
|
|
|
|
||||
Version |
|
P/G No. |
|
|
|
|
Parts name |
tive |
change- |
Note |
|||
No. |
name |
|
|
|
|
Price |
|||||||
|
|
|
|
Parts code |
|
Parts code |
|
time |
ability |
|
|||
|
|
|
|
|
|
|
rank |
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Europe |
|
|
|
|
RCORF5013BCZZ |
AB |
|
|
|
|
|
|
|
U.K |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
JX-AF3 |
Hong |
|
5 |
|
— |
|
|
|
Core screw |
95/6 |
6 |
|
|
|
kong |
|
|
|
|
RCILZ7020SCZZ |
AG |
|
|
|
|
|
|
|
Australia |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
<Interchange> |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
1. Interchangeable. |
|
|
|
|
|
4. Not interchangeable. |
|
|
|
|||
|
|
|
|
|
|
||||||||
|
2. Current type can be used in place of new type. |
|
5. Interchangeable if replaced with same types of |
||||||||||
|
New type cannot be used in place of current type. |
related parts in use. |
|
|
|
3. Current type cannot be used in place of new type.
6. Others.
New type can be used in place of current type.
Parts marked with “ ! ” is important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the safety and performance of the set.
2/2