Date: Feb. 28, 1995
TRANSPARANT ORIGINAL DOCUMENT READER UNIT: JX6F12
[Service Information]
No. : CX-177
APPLICATION OF GREASE TO THE SUB
SLIDE SHAFT
1.Model name: JX3F6/12
2.General: Grease has been applied to the sub slide shaft to prevent jags. The grease that was
used is described below.
Parts code Position rank Parts name
0CHFLOILG 311S AZ Froil G 311S
When greasing, four drops of grease should be applied to the shaft, and the bearing
should be moved left and right so that the grease is applied evenly to the whole shaft.
Note: Grease should be applied to only the sub slide shaft when jags occur, or during
normal maintenance operations.
Bearing
Sub slide shaft
3.Action: From 1995 January production
SHARP CORPORATION Printer and Scanner Division
Orange
C