Date: Feb. 20, 1995
COLOR IMAGE SCANNER: JX3F12
CHANGE OF CONDENSERS AND PARTS GUIDE
CORRECTIONS IN RELAY PWB AND CCD PWB
1.Model name: JX3F6, 12
2.General: We had changed the type of the resistor R13 (100Ω) in the relay PWB from normal one
to the fuse resistor due to unusual heat since August 1994 production. However,
another problem came out. When you connect and disconnect the FSU I/F cable during
the scanner JX330 power on, the changed resistor was cut and the machine did not
recognize the transparent copy scanner unit because ratching up occurred in the CCD
sensor. This trouble is explained in the instruction manual and does not occur under the
normal condition. We have changed the electrolysis condensers in the relay PWB and
CCD PWB to prevent this. We also have changed descriptions of the relay PWB
resistor in the parts’ guide since it was false.
No. : CX-172
3.Description: 1. Change due to ratch up of CCD sensor
<Relay PWB> <Current> <New>
➀ Condenser C7 VCEAJU1VW476M VCEAJU1VW106M
(4.7µF/35V) (10µF/35V)
➁ Condenser C9 VCEAJU1VW476M VCEAJU1EW475M
(4.7µF/35V) (4.7µF/25V)
➂ Resistor R13 VRD-HT2HY101J VRG-ST2HC101J
(1/2W 100Ω ±5%) Fuse resistor (1/2W 100Ω ±5%)
<CCD PWB> <Current> <New>
Condenser C9 22µF/16V 4.7µF/25V
Condenser C11 and
Condenser C13 parallel to
each other and attach
them to the board. — 10µF/16V added
Changes of condensers in both PWBs are carried out at the same time. However, the
CCD PWB needs to be adjusted with special tools. Therefore please change them
under the condition that they are attached to the carriage unit, then remove the CCD
cover and screws which attach the cover. Be sure not to shift the focal point of CCD.
<Notes>
1. About disconnecting and connecting of the I/F cable connector, there is a description
in the instruction manual as follows: Turn the power off when disconnect or connect.
When your customer is in troubles above, please explain it and you too, be careful it
and offer service.
1/3
SHARP CORPORATION Printer and Scanner Division
Orange
C
2. We have corrected the parts’ list in the parts’ guide. Please correct as following table.
P/G No.
6 -39 VRD-RC2EY391J Delete — Resistor (1/4 390Ω ±5%) R5
6 -45
6 -51 VRD-RC2EY102J Delete — Resistor (1/4 1KΩ ±25%) R19
Current New
VRD-RC2EY470J Delete — Resistor (1/4 47Ω ±5%) R11
Parts code
Price
rank
Parts name etc.
3. We have changed the relay PWB and CCD PWB in the service manual as following
diagram due to the change 1 above.
2/3
Change to the condenser
C7 10µF 35V
Change to the Fuse resistor
Change to the condenser C9 4.7µF 25V