SHARP CX123 Technical Report

Date : Mar. 22, 1993

COLOR IMAGE SCANNER :

JX-610

No. : CX-123

 

 

[Service information]

 

 

 

 

 

 

 

 

PARTS CODE CORRECTION (2)

 

1.Model name:

 

 

 

JX-610

2.General:

Please note correction and addition in your parts guide.

3.Description:

1)

ADC PWB parts code change and discontinuance.

 

2)

Edge sheet employment and original cover structural change.

4.Action:

Since the first production unit.

 

Because some device is needed when setting a document over the film scanner, an

 

edge sheet is pasted over the document table glass.

Document guide

Location to be pasted.

1/2

SHARP CORPORATION Printer and Scanner Division

Orange

C

SHARP CX123 Technical Report

The structure of the original cover mat is changed as the edge sheet is newly used.

Document guide

Edge sheet

Original cover mat

Original cover mat dimensional change

Current

New

Ref.

Model

Version

P/G No.

Current parts

New parts

 

Parts name

Effec-

Inter-

Note

 

 

 

tive

chang-

No.

name

 

 

 

 

 

Parts code

Parts code

Price

 

time

ability

 

 

 

 

 

 

 

 

 

 

 

rank

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17 -175

VS2SC1214//-1

Discontinued

Transistor

'92/10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RCORF6668RCZZ

RCORF6668RCZA

AH

Core

'92/10

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15 -48

VCCCPU1HH330J

Discontinued

Capacitor

'92/10

 

 

JX-610

All

-49

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8 -1

CCOVH0135SC05

Not changed.

BL

O.C

'92/10

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PSHEZ7124XCZZ

AH

Egge sheet

'92/10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UKOG-7015XCZZ

AH

Special tool

'92/10

 

 

 

 

 

 

 

 

 

 

 

 

<Interchange>

1.

Interchangeable.

4.

Not interchangeable.

 

 

 

 

2.

Current type can be used in place of new type.

5.

Interchangeable if replaced with same types of

 

New type cannot be used in place of current type.

 

related parts in use.

 

 

 

 

3.

Current type cannot be used in place of new type.

6.

Others.

 

New type can be used in place of current type.

 

 

 

 

 

 

 

Parts marked with “ ! ”is important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the safety and performance of the set.

2/2

Loading...