Sharp CV-P12LX, CV-P09LX, CV-P10MX, CV-P10LC User Manual

CV-P09LX
PORTABLE TYPE ROOM AIR CONDITIONER
CV-P12LX CV-P10LC CV-P10MX
INSTALLATION AND OPERATION MANUAL
CLIMATISEUR DE CHAMBRE DE TYPE PORTATIF
MANUEL D’INSTALLATION ET D’UTILISATION
MANUAL DE INSTALACIÓN Y FUNCIONAMIENTO
ENGLISH
FRANÇAIS
ESPAÑOL
*Plasmacluster is a trademark of SHARP
Corporation.
*Plasmacluster est une marque de
commerce de SHARP Corporation.
*Plasmacluster es una marca registrada
de SHARP Corporation.
ENGLISH
This manual explains the proper use of your new air conditioner. Please read this manual carefully before using the product. This manual should be kept in a safe place for handy reference.
CONTENTS
•FOR CUSTOMER ASSISTANCE (U.S.) .................................E-2
•CONSUMER LIMITED WARRANTY (U.S.) ............................E-3
•FOR CUSTOMER ASSISTANCE (CANADA) .........................E-4
•CONSUMER LIMITED WARRANTY (CANADA) ....................E-5
•PRECAUTIONS.......................................................................E-6
•LOCATION ..............................................................................E-9
•INCLUDED ..............................................................................E-9
•PART NAMES .........................................................................E-10
•INSTALL WINDOW PANEL ....................................................E-12
•INSTALLATION AND REMOVAL OF EXHAUST HOSE.........E-16
•PRE-OPERATION CHECKS ...................................................E-18
•COOL MODE...........................................................................E-20
•DEHUMIDIFICATION MODE ..................................................E-21
•FAN MODE..............................................................................E-22
•VENTILATION MODE .............................................................E-22
•TO CHANGE AIR FLOW DIRECTION ....................................E-23
•PLASMACLUSTER OPERATION ...........................................E-24
•MEGA COOL OPERATION.....................................................E-25
•ONE-HOUR OFF TIMER.........................................................E-25
•TIMER OPERATION ...............................................................E-26
•MAIN UNIT OPERATION ........................................................E-28
•DRAINAGE ..............................................................................E-29
•MAINTENANCE ......................................................................E-30
•BEFORE CALLING FOR SERVICE ........................................E-31
ENGLISH
Declaration of Conformity
SHARP ROOM AIR CONDITIONER CV-P09LX, CV-P12LX, CV-P10LC, CV-P10MX
This device complies with Part 18 of FCC rules.
Responsible Party:
SHARP ELECTRONICS CORPORATION. Sharp Plaza, Mahwah, New Jersey 07430-2135 TEL: 1-800-BE-SHARP
Declaration of Conformity
SHARP ROOM AIR CONDITIONER CV-P09LX, CV-P12LX, CV-P10MX
This ISM device complies with Canadian ICES-001
Responsible Party:
SHARP ELECTRONICS OF CANADA LTD. 335 Britannia Road East Mississauga, Ontario L4Z 1W9 Canada TEL: (905) 568-7140
E-1
FOR CUSTOMER ASSISTANCE
To aid in answering questions if you call for service or for reporting loss or theft, please record below the model and serial number located on the back side of the unit.
MODEL NUMBER
SERIAL NUMBER
DATE OF PURCHASE
Dealer Name
Address
City
State
Zip
Telephone
(the United States)
TO PHONE: Dial 1-800-BE-SHARP (237-4277) for:
SERVICE (for your nearest Sharp Authorized Servicer) PARTS (for your Authorized Parts Distributor) ACCESSORIES ADDITIONAL CUSTOMER INFORMATION
TO WRITE: For service problems, warranty information, missing items and other assistance:
Sharp Electronics Corporation Customer Assistance Center 1300 Naperville Drive Romeoville, IL 60446-1091
TO ACCESS THE INTERNET: www.sharpusa.com
Please provide the following information when you write or call: model number, serial number, date of purchase, your complete mailing address (including zip code), your daytime telephone number (including area code) and description of the problem.
E-2
CONSUMER LIMITED WARRANTY
CONSUMER LIMITED WARRANTY FOR THE U.S. USERS
SHARP ELECTRONICS CORPORATION warrants to the first consumer purchaser that this Sharp brand product (the “Product”), when shipped in its original container, will be free from defective workmanship and materials, and agrees that it will, at its option, either repair the defect or replace the defective Product or part thereof with a new or remanufactured equivalent at no charge to the purchaser for parts or labor for the period(s) set forth below.
This warranty does not apply to any appearance items of the Product nor to the additional excluded item(s) set forth below nor to any Product the exterior of which has been damaged or defaced, which has been subjected to improper voltage or other misuse, abnormal service or handling, or which has been altered or modified in design or construction.
In order to enforce the rights under this limited warranty, the purchaser should follow the steps set forth below and provide proof of purchase to the servicer.
The limited warranty described herein is in addition to whatever implied warranties may be granted to purchasers by law. ALL IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR USE ARE LIMITED TO THE PERIOD(S) FROM THE DATE OF PURCHASE SET FORTH BELOW. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
Neither the sales personnel of the seller nor any other person is authorized to make any warranties other than those described herein, or to extend the duration of any warranties beyond the time period described herein on behalf of Sharp.
The warranties described herein shall be the sole and exclusive warranties granted by Sharp and shall be the sole and exclusive remedy available to the purchaser. Correction of defects, in the manner and for the period of time described herein, shall constitute complete fulfillment of all liabilities and responsibilities of Sharp to the purchaser with respect to the Product, and shall constitute full satisfaction of all claims, whether based on contract, negligence, strict liability or otherwise. In no event shall Sharp be liable, or in any way responsible, for any damages or defects in the Product which were caused by repairs or attempted repairs performed by anyone other than an authorized servicer. Nor shall Sharp be liable or in any way responsible for any incidental or consequential economic or property damage. Some states do not allow the exclusion of incidental or consequential damages, so the above exclusion may not apply to you.
THIS WARRANTY GIVES YOU SPECIFlC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.
Your Product Model Number & Description:
Warranty Period for this Product:
Additional Item(s) Excluded From Warranty Coverage (If any):
Where to Obtain Service:
What to Do to Obtain Service:
CV-P09LX, CV-P12LX, CV-P10LC or CV-P10MX Portable Air Conditioner. Be sure to have this information available
when you need service for your Product. One (1) year parts and labor from date of purchase. The
warranty period continues for a total of five (5) years from date of purchase for the Sealed Cooling System parts; labor and service are not provided free of change for this additional period.
Appearance items of the Product, filters, or accessories, or any printed materials.
Product which has been used for rental and/or commercial purposes.
From a Sharp Authorized Servicer located in the United States. To find the location of the nearest Sharp Authorized Servicer, call Sharp Toll Free at 1-800-BE-SHARP.
Contact your Sharp Authorized Servicer to obtain in-home service for this Product.
The Servicer will come to your home, and if it is necessary to remove the Product, the Servicer will reinstall it. Be sure to have Proof of Purchase available.
ENGLISH
TO OBTAIN SUPPLY, ACCESSORY OR PRODUCT INFORMATION, CALL 1-800-BE-SHARP, OR VISIT OUR WEBSITE AT www.sharpusa.com
SHARP ELECTRONICS CORPORATION
Sharp Plaza, Mahwah, New Jersey 07430-2135
E-3
FOR CUSTOMER ASSISTANCE (Canada)
To aid in answering questions if you call for service or for reporting loss or theft, please record below the model and serial number located on the back side of the unit.
MODEL NUMBER
SERIAL NUMBER
DATE OF PURCHASE
Dealer Name
Address
City
Province
Postal Code
Telephone
TO PHONE: Dial 1-905-568-7140 for:
SERVICE (for your nearest Sharp Authorized Servicer) PARTS (for your Authorized Parts Distributor) ACCESSORIES ADDITIONAL CUSTOMER INFORMATION
TO WRITE: For service problems, warranty information, missing items and other assistance:
Sharp Electronics of Canada Ltd. Customer Care 335 Britannia Road East Mississauga, Ontario L4Z 1W9
TO ACCESS THE INTERNET: www.sharp.ca
Please provide the following information when you write or call: model number, serial number, date of purchase, your complete mailing address (including Postal Code), your daytime telephone number (including area code) and description of the problem.
E-4
T
O
B
E
T
H
E
B
E
S
T
T
H
R
O
U
G
H
C
U
S
T
O
M
E
R
S
A
T
I
S
F
A
C
T
I
O
N
SERVICE
R
LIMITED WARRANTY
Consumer Electronics Products
Congratulations on your purchase!
Sharp Electronics of Canada Ltd. (hereinafter called “Sharp”) gives the following express warranty to the first consumer purchaser for this Sharp brand product, when shipped in its original container and sold or distributed in Canada by Sharp or by an Authorized Sharp Dealer:
Sharp warrants that this product is free, under normal use and maintenance, from any defects in material and workmanship. If any such defects should be found in this product within the applicable warranty period, Sharp shall, at its option, repair or replace the product as specified herein.
This warranty shall not apply to: (a) Any defects caused or repairs required as a result of abusive operation, negligence, accident, improper installation
or inappropriate use as outlined in the owner’s manual.
(b) Any Sharp product tampered with, modified, adjusted or repaired by any party other than Sharp, Sharp’s Authorized
Service Centres or Sharp’s Authorized Servicing Dealers.
(c) Damage caused or repairs required as a result of the use with items not specified or approved by Sharp, including
but not limited to head cleaning tapes and chemical cleaning agents.
(d) Any replacement of accessories, glassware, consumable or peripheral items required through normal use of the
product including but not limited to earphones, remote controls, AC adapters, batteries, temperature probe,
stylus, trays, filters, belts, ribbons, cables and paper. (e) Any cosmetic damage to the surface or exterior that has been defaced or caused by normal wear and tear. (f) Any damage caused by external or environmental conditions, including but not limited to transmission line/
power line voltage or liquid spillage. (g) Any product received without appropriate model, serial number and CSA /cUL markings. (h) Any products used for rental or commercial purposes. (i) Any installation, setup and/or programming charges.
Should this Sharp product fail to operate during the warranty period, warranty service may be obtained upon delivery of the Sharp product together with proof of purchase and a copy of this LIMITED WARRANTY statement to an Authorized Sharp Service Centre or an Authorized Sharp Servicing Dealer. In home warranty service may be provided at Sharp’s discretion on any Sharp television with the screen size of 27” or larger and on any Sharp Over-the-Range Microwave Oven.
This warranty constitutes the entire express warranty granted by Sharp and no other dealer, service centre or their agent or employee is authorized to extend, enlarge or transfer this warranty on behalf of Sharp. To the extent the law permits, Sharp disclaims any and all liability for direct or indirect damages or losses or for any incidental, special or consequential damages or loss of profits resulting from a defect in material or workmanship relating to the product, including damages for the loss of time or use of this Sharp product or the loss of information. The purchaser will be responsible for any removal, reinstallation, transportation and insurance costs incurred. Correction of defects, in the manner and period of time described herein, constitute complete fulfillment of all obligations and responsibilities of Sharp to the purchaser with respect to the product and shall constitute full satisfaction of all claims, whether based on contract, negligence, strict liability or otherwise.
ENGLISH
WARRANTY PERIODS: Parts & Labour (exceptions noted)
Audio Products 1 year Camcorder 1 year DVD Products 1 year Projector 1 year (lamp 90 days) LCD TV 1 year Microwave Oven 1 year (magnetron component-4 additional years) Air Purifier 1 year Portable Air Conditioner 1 year
To obtain the name and address of the nearest Authorized Sharp Service Centre or Dealer, please contact:
SHARP ELECTRONICS OF CANADA LTD. 335 Britannia Road East Mississauga, Ontario L4Z 1W9
For more information on this Warranty, Sharp Extended Warranty
Offers, Sharp Canada Products, Accessory Sales, Dealer or
Service Locations, please call (905) 568-7140
Visit our Web site: www.sharp.ca
E-5
PRECAUTIONS
Points to keep in mind when using your air conditioner.
WARNINGS FOR USE
• Install the air conditioner in accordance with the installation instructions in the latter section of this manual.
• Do not modify any part of this product.
• Do not insert anything into any part of the unit.
• Ensure the power supply used has an appropriate voltage rating.
Only use a three-pin grounded electrical AC socket rated 125V, 60Hz, and 15 amps or more as shown on the right. Use of a power supply with an improper voltage rating can result in damage to the unit and possibly fire.
• Always use a fuse with the proper amp rating.
Do not, under any circumstances, use wire, pins or other objects in place of a proper fuse.
• In the event of any abnormality with the air conditioner (ex. a burning smell), turn it off immediately and disconnect the power supply.
WARNING FOR POWER SUPPLY CORD
• This air conditioner uses a plug with a built-in fuse.
Read the precautions on the plug before using the air conditioner.
• Always conduct a “Power Plug Check” (See Page 18) before use to confirm the power plug functions normally.
• This power plug must only be plugged into an appropriate wall socket. Do not use in conjunction with any extension cords.
• Push the power plug securely into the socket and make sure it is not loose.
• Do not pull, deform, or modify the power supply cord, or immerse it in water.
Pulling or misuse of the power supply cord can result in damage to the unit and cause electrical shock.
• A damaged power supply cord must be replaced with a new power supply cord ob­tained from the product manufacturer and not repaired. Replacement must be per­formed by manufacture's service agent in order to avoid a hazard.
NOTE
Radio or TV Interference
If this room air conditioner should cause interference to radio or television reception, try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the room air conditioner and radio/TV receiver.
• Connect the room air conditioner into an outlet on a circuit different from that to which the radio/TV receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This product fulfils the requirement of the International standard CISPR 11. In conformity with this standard, this product is classified as group 2 class B equipment. Group 2 means that the equipment intentionally generates radio-frequency in the form of electromagnetic radiation for electro-discharge machining equipment. Class B equipment means that the equipment suitable to be used in domestic establishments.
E-6
WARNING ABOUT GROUNDING
• Improper use of the grounding plug can re­sult in the risk of electric shock.
This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of an electric shock by providing a less resistant conduit for the electric current. This appliance is equipped with a cord that has a grounding wire connected to a grounding plug. The plug must be plugged into a socket that is properly installed and grounded.
• Do not under any circumstances cut or re­move the round grounding pin from this plug.
Consult a qualified electrician or serviceman if the grounding instructions are not completely understood, or if in any doubt as to whether the appliance is properly grounded. If a grounding adapter is used, make sure the electrical box is fully grounded.
3-Pin plug
Screw
Grounding pin
3-Pin socket
Grounding adapter
Grounding wire
Tab for grounding screw
Grounded electrical box
Grounded electrical box
ENGLISH
USAGE CAUTIONS
• Ventilate the room periodically during use, especially if using gas appliances.
• Be sure to turn the unit off and disconnect the power supply cord before performing any maintenance or cleaning.
• Do not splash or pour water directly onto the unit.
Water can cause electrical shock or equipment damage.
• Drainage should be performed whenever moving the air conditioner. (See Page 29)
If any water remains in the tank, it may spill out while being moved.
• Remove the window panel in the event of particularly adverse weather.
Extremely adverse weather may cause water to leak in through the openings.
• To ensure proper drainage, the drainage hose must have no kinks or be on a differ­ent level during dehumidification mode.
The drained water may spill out into the room.
• The temperature around the drainage hose must not be below freezing point when used.
Drained water may freeze inside the hose, causing water inside the unit to overflow into the room.
• Do not block the exhaust air outlet with obstacles.
Cooling performance may be reduced or stop completely.
E-7
PRECAUTIONS
NOTES ON OPERATION
• Allow 3 minutes for the compressor to restart cooling.
If you turn the air conditioner off and immediately restart it, allow three minutes for the compressor to restart cooling. There is an electronic device in the unit that keeps the compressor turned off for three minutes for safety.
• In the event of a power failure during use, allow 3 minutes before restarting the unit.
After power is reinstated, restart the air conditioner. If the power was off for less than three minutes, be sure to wait at least three minutes before restarting the unit. If you restart the air conditioner within three minutes, a protective device in the unit may cause the compres­sor to shut off. This protective device will prevent cooling for about 5 minutes. Any previous settings will be canceled and the unit will return to its initial settings.
• Low temperature operation: Is your unit freezing up?
Freezing may occur when the unit is set close to 64°F in low ambient temperature condi­tions, especially at night. In these conditions, a further temperature drop may cause the unit to freeze. Setting the unit to a higher temperature will prevent it from freezing.
• Dehumidification mode increases room temperature.
The unit generates heat during dehumidification mode and the room temperature will rise. Warm air will be blown out from the Exhaust air outlet, but this is normal and does not indicate a problem with the unit.
• This air conditioner blows the warm air generated by the unit outside the room via the exhaust hose while in cool mode.
Accordingly, the same amount of air as that blown out will enter the room from outside through any openings into the room.
• When cooling operation is performed at high humidity conditions, water tank inside the unit may frequently become full.
When water tank inside the unit is full, the unit stops operating and TIMER, OPERATION and MEGA COOL lamps will blink. In this case, perform drainage to drain out water within the unit. (See page 29)
OPERATING CONDITIONS
• The air conditioner must be operated within the temperature range indicated below.
MODE ROOM TEMPERATURE
COOL 64°F~95°F
Dehumidification 59°F~95°F
• A built-in safety device may cut off operation if the temperature exceeds these limits.
• When cooling operation is performed at high room temperature, the fan may run slightly slowed.
ENERGY EFFICIENCY TIPS
• Avoid direct sunlight.
Close blinds, drapes or shades to keep out direct sunlight while in cooling mode.
• Keep the filter clean.
Keeping the filter clean greatly aids efficient operation. A dirty filter blocks the flow of air, making your air conditioner work harder and less effi­ciently. See page 30 on how to clean the filter.
• Turn off unnecessary lights.
Your air conditioner must remove the heat produced by your lights or other heat-producing appliances. Turn off any lights or appliances that are not in use.
• Turn off the air conditioner when no one is home.
Use only when necessary. The less time the air conditioner is used, the lower the running costs.
E-8
LOCATION
• The air conditioner should be placed on a firm founda­tion to minimize noise and vibration. For safe and se­cure positioning, place the unit on a smooth, level floor strong enough to support the unit.
• The unit has casters to aid placement, but it should only be rolled on smooth, flat surfaces. Use caution when rolling on carpet surfaces. Do not attempt to roll the unit over objects.
• The unit must be placed within reach of a properly rated grounded socket.
• Never place any obstacles around the air inlet or outlet of the unit.
• Allow at least 12" (30cm) of space from the wall for effi­cient air-conditioning.
INCLUDED
ENGLISH
MIN.12" (30cm)
MIN.12" (30cm)
Exhaust hose (1) Window exhaust adapter (1)
Exhaust cover (1)
Adjustment panel (1)
Window panel (1)
Rain guard (2)
Hose clamp (1)
Insect guard net (1)
Screw (8)
Foam seal (1)
Remote control (1)
Drainage Grommet (1)
Extension panel (1)
Foam seal (3)
(adhesive type)A
(thickness:1/5") (thickness:2/5")
Battery (2) (AAA.R03)
Bracket (1)
Foam seal (1)
(adhesive type)B
Manual (1)
SUGGESTED TOOLS FOR WINDOW PANEL
INSTALLATION
1. Screwdriver(medium size Phillips) 2. Tape measure or ruler 3. Knife or scissors
4. Saw (In the event that the window panel needs to be cut down in size because the
window is too narrow for direct installation.)
E-9
PART NAMES
FRONT VIEW
1 2
3
4 5
6 7 8 9 0 0 0
1 Air Outlet
2 Vertical louvers
3 Horizontal louvers
4 PLASMACLUSTER Lamp (blue)
5 Remote control signal receiver
window
6 POWER Button
7 OPERATION Lamp (red)
8 TIMER Lamp (orange)
9 MEGA COOL Lamp (green)
0 Air inlet
REAR VIEW
q w
e r
t y
u
i o p a
q Exhaust air outlet
w Window exhaust adapter
e Exhaust hose
r Remote control hook
t Air filters
y Drainage nozzle and stopcock
u Power supply cord hooks
i Drainpipe nozzle and stopcock
o Power supply cord
p Power plug
a Casters(4)
NOTE: Actual unit might vary slightly from above illustration.
E-10
REMOTE CONTROL
1
2 3
4 5 6 7 8 9 0 q w e r t
1 Transmitter
2 Display
3 POWER Button
ENGLISH
4 LIGHTS Button
5 TEMPERATURE Button
6 PLASMACLUSTER Button
7 1 hr OFF Button
8 MODE Button
9 ON TIMER Button
0 FAN Button
q OFF TIMER Button
w CANCEL Button
e LOUVERS Button
REMOTE CONTROL DISPLAY
y
u
i
o
p
a
s
r RESET Button
t MEGA COOL Button
y MODE SYMBOLS
: COOL : DEHUMIDIFICATION
: FAN : VENTILATION
u MEGA COOL SYMBOL i PLASMACLUSTER SYMBOL o FAN SPEED SYMBOLS
: AUTO : Manual setting
p TEMPERATURE AND TIMER COUNT
DOWN INDICATOR
a TRANSMITTING SYMBOL s ON TIMER / OFF TIMER SYMBOL
E-11
INSTALL WINDOW PANEL
Installation in a double-hung sash window
(See page 14 for installation in a sliding sash window. )
Connect the rain guards to the insect
1
guard net.
Insert all three projections on each rain guard into the holes in the insect guard net.
Side “A” will now be uppermost, as indi­cated in the diagram.
Insect guard net
Projection
Hole
Rain guard
"A"
Attach the guard combined above to the
2
window panel
Push the insect guard net firmly to ensure that its four projections fit into the holes in the window panel.
Side “A” will now be at the top, as indicated in the diagram.
Cut the foam seal A (adhesive type) to
3
the proper length and attach it to the window stool.
Attach the window panel to the window
4
stool.
If the inner width of the window is be­tween 22" (559mm) and 24" (609mm) inclusive.
"A"
Window panel
Projection
Window panel
Foam seal A (adhesive type)
Exhaust cover
Cut
The window panel cannot be installed in windows less than 22" (559mm) wide, as you will be unable to shut the exhaust cover.
(1) Remove the adjustment panel from the
window panel, and cut the window panel to the same width as the window.
(2) Open the window sash and place the win-
dow panel on the window stool
(3) Secure the window panel to the window
stool with 2 screws.
E-12
Adjustment panel
Window panel
22"~ 24"
Window stool
If the inner width of the window is between 24" (609mm) and 36.8" (934mm) inclusive.
(1) Open the window sash and place the
window panel on the window stool.
(2) Slide the adjustment panel to fit the
window frame width.
(3) Secure the window panel to the stool with
3 screws.
If the inner width of the window is between 36.8" (934mm) and 48" (1219mm) inclusive.
(1) Attach the extension panel to the
adjustment panel.
(2) Open the window sash and place the win-
dow panel on the window stool.
(3) Slide the adjustment and extension
panels to fit the window frame width.
(4) Secure the window panel to the window
stool with 4 screws.
Adjustment panel
ENGLISH
24"~36.8"
Extension panel
36.8"~48"
Cut the foam seals (adhesive type) A and
5
B to the proper length and attach it to the window panel.
Attach foam seal A to the window panel and extension panel, and attach foam seal B to the adjustment panel.
Close the window sash securely against
6
the Window panel.
Cut the foam seal to an appropriate length
7
and seal the opening between the top of the inner window sash and the outer win­dow sash.
Attach a bracket with the screw.
8
Foam seal
Foam seal B (adhesive type)
Foam seal A (adhesive type)
Bracket
E-13
INSTALL WINDOW PANEL
Installation in a sliding sash window
(See page 12 for installation in a double-hung window.)
Connect the rain guards to the insect
1
guard net.
Insert all three projections on each rain guard into the holes in the insect guard net.
Side “A” will now be uppermost, as indicated in the diagram.
Attach the guard combined above to the
2
window panel.
Push the insect guard net firmly to ensure that its four projections fit into the holes in the window panel. Side “A” will now be at the top, as indicated in the diagram, when it is installed in the window.
Insect guard net
Hole
Projection
Projection
"A"
Rain guard
Window panel
"A"
Cut the foam seal A (adhesive type) to the
3
proper length and attach it to the window frame.
Install the window panel into the window
4
frame.
If the inner height of the window is between 22" (559mm) and 24" (609mm) inclusive.
The window panel cannot be installed in windows less than 22" (559mm) high, as you will be unable to shut the exhaust cover.
(1) Remove the adjustment panel from the
window panel, and cut the window panel to the same height as the window.
(2) Open the window sash and place the
window panel on the window frame.
Window panel
Window panel
Exhaust cover
Adjustment panel
Foam seal A (adhesive type)
Cut
22"~24"
(3) Secure the window panel to the window
frame with 2 screws.
E-14
If the inner height of the window is between 24" (609mm) and 36.8" (934mm) inclusive.
(1) Open the window sash and place the
window panel on the window frame.
(2) Slide the adjustment panel to fit the
window frame height.
(3) Secure the window panel to the window
frame with 3 screws.
If the inner height of the window is be­tween 36.8" (934mm) and 48" (1219mm) inclusive.
(1) Attach the extension panel to the
adjustment panel.
(2) Open the window sash and place the
window panel on the window frame.
(3) Slide the adjustment and extension
panels to fit the window frame height.
(4) Secure the window panel to the window
frame with 4 screws.
Adjustment panel
Extension panel
24"~36.8"
36.8"~48"
ENGLISH
Cut the foam seals (adhesive type) A and
5
B to the proper length and attach them to the window panel.
Attach foam seal A to the window panel and extension panel, and attach foam seal B to the adjustment panel.
Close the window sash securely against
6
the Window panel.
Cut the foam seal to an appropriate length
7
and seal the opening between the side of the inner window sash and the outer win­dow sash.
Attach a bracket with the screw.
8
Foam seal B (adhesive type)
Foam seal A (adhesive type)
Bracket
Foam seal
E-15
INSTALLATION AND REMOVAL OF EXHAUST HOSE
The exhaust hose must be installed or removed in accordance with the usage mode.
MODE EXHAUST HOSE COOL, FAN, VENTILATION, DEHUMIDIFICATION with no container Install DEHUMIDIFICATION with container(minimum capacity 3
Installation of the exhaust hose
Attach the window exhaust adapter to
1
the exhaust hose.
Extend one end of the exhaust hose and insert it into the window exhaust adapter, and turn it (approx. three times) until it stops. Make sure they are securely attached afterwards.
Attach the exhaust hose adapter to the
2
unit.
Insert the two projections on the exhaust hose adapter into the two holes on the unit, and firmly attach them to each other.
1
/
gallons) Remove
2
Extend
Exhaust hose
Window exhaust adapter
Projection
Slide and open the exhaust cover on
3
the window panel, and attach the win­dow exhaust adapter.
Surface of window exhaust adapter marked "TOP" should be at the top when it is installed in a double-hung sash window. Surface of window exhaust adapter marked "TOP" should be on the window frame side when it is installed in a sliding sash window.
The exhaust hose should be as short as possible for operational efficiency; however, it must not be twisted or bent.
Unacceptable
Acceptable
Acceptable
Hole
"TOP"
E-16
Removal of the exhaust hose
Remove the window exhaust adapter.
1
Pull out and remove the window exhaust adapter by pushing down two “PUSH” markings, and slide and close the exhaust cover in the window panel.
Remove the exhaust hose adapter from
2
the unit.
Lift up and remove the exhaust hose adapter from the unit by pushing down on the two projections.
ENGLISH
"PUSH"
Projection
E-17
PRE-OPERATION CHECKS
POWER PLUG CHECK
This air conditioner uses a fused power plug. Always check the power plug before use.
Press the RESET button.
1
Insert the power plug into the wall socket.
2
Press the TEST button.
3
You will hear a CLICK if the circuit breaker is functioning correctly.
Press the RESET button until you hear another
4
CLICK.
The circuit breaker is activated, power is supplied, and the air conditioner is now ready for use.
Do not attempt to use the air conditioner if the above procedure is impossible, as it is malfunctioning. Disconnect the power plug and request service.
RESET
TEST
LOADING BATTERIES Use two AAA (R03) batteries.
Remove the battery cover at the
1
back of the remote control. Insert batteries into the compart-
2
ment, making sure the
polarities are correctly
aligned.
• Lines will appear on the display when batteries are properly in­stalled.
Reattach the battery cover.
3
Press the RESET button using a
4
thin pointed implement.
NOTES:
• The battery should last approximately one year under normal use.
• When replacing the batteries, always change both batteries at the same time, and make sure they are the same type.
• If the remote control does not operate normally after replacing the batteries, press the RESET button using a thin pointed implement.
• If you will not be using the unit for a prolonged period, remove the batteries from the remote control.
±±
± and
±±
Battery cover
E-18
HOW TO USE THE REMOTE CONTROL
Point the remote control towards the units signal receiver window and press the desired button. A beep will sound when the unit receives the signal.
• Make sure nothing, such as curtains, blocks the signal receiver window.
• The remote control operates up to 23 feet (7 meters) away.
CAUTION
• Do not expose the signal receiver window to direct sunlight. This may adversely affect its operation. If necessary, close the curtains to block out the sunlight.
• Use of a fluorescent lamp in the same room may interfere with transmission of the signal.
• The unit may be affected by signals emitted from other remote controllers for televisions, VCRs or other equipment used in the same room.
• Do not leave the remote control exposed to direct sunlight or near a heater. Pro­tect the remote control from moisture and shock which can discolor or damage it.
ENGLISH
To prevent the remote control from being misplaced, hook it to the unit when not in use.
When attached, to remove the remote control from the unit, lift the remote control up slightly and pull it out.
Remote control hook
E-19
COOL MODE
"CLOSE" position
Drainage nozzle
Stopcock
2 3
1
Install the exhaust hose (See Page16), turn the drainage nozzle to the CLOSE position, and check the drainage nozzle is covered with the stopcock.
Press the MODE button to select COOL
1
mode.
COOL DEHUM FAN VENT
3
Press the POWER button to start op-
2
eration.
• The red OPERATION lamp on the unit will light.
Press the TEMPERATURE button to set
3
the desired temperature.
• The temperature can be set within the range
of 64°F to 86°F.
1 4
Press the FAN button to set the de-
4
sired fan speed.
AUTO QUIET LOW HIGH
TO TURN OFF
Press the POWER button again.
• The red OPERATION lamp on the unit will turn off.
E-20
DEHUMIDIFICATION MODE
In this mode, the air conditioner dehumidifies the room.
Dehumidification with container
Remove the exhaust hose (See Page 17)
1
Turn the drainage nozzle to the OPEN position.
2
Pull the stopcock out from the drainage nozzle.
3
• When the stopcock is removed, a small amount of water may be discharged from the drainage nozzle.
• Always perform this procedure with the unit turned off. Drain water will spout out if attempted during operation.
Insert the hose clamp onto a standard commer-
4
cially-available hose (5/8" inner diameter, 7/8" outer diameter) and attach the drain grommet to the hose.
Attach the hose to the drainage nozzle, and secure
5
it with the hose clamp.
• Insert the hose securely into a container with a minimum capacity of 31/2 gallons. Be sure to monitor the water level in the container and empty as necessary. Do not operate in dehumidify mode for more than 8 hours at a time. Be sure to empty the water container whenever dehumidify mode is started. Failure to empty the water container can cause the container to overflow and cause damage to underlying materials.
• Set the hose sloping downwards for easier drainage. Moreover, do not bend the hose at any point, nor allow the end to be submerged in water.
"OPEN" position
Drainage nozzle
Stopcock
Drain grommet
Hose clamp
Hose
Dehumidification with no container
If draining of the water is not desirable, install the exhaust hose (See Page 16), turn the drainage nozzle to the
CLOSE position, and check that the drainage nozzle is covered with the stopcock. In this operation, the water tank inside the unit may be full, the unit stops operating and then the TIMER, OPERATION and MEGA COOL lamps are blinking, depending on room condition. In this case, drain out the water within the unit (See Page 29).
ENGLISH
Press the MODE button to select DEHU-
1
MIDIFICATION mode.
COOL DEHUM FAN VENT
2
1
Press the power button to start opera-
2
tion.
• The red OPERATION lamp on the unit will light.
• The temperature cannot be set.
• The fan speed is preset to AUTO and cannot be changed.
TO TURN OFF
Press the POWER button again.
CAUTION
When operating dehumidification with container, the unit generates heat during dehumidifica­tion mode and the room temperature will rise. Operate dehumidification with no container if you don't want the room temperature to rise. This will help to slightly drop the room temperature, but dehumidification performance will become less effective than when operat­ing dehumidification with container.
• The red OPERATION lamp on the unit will turn off.
E-21
FAN MODE
In this mode, the air conditioner simply circulates the air without cooling it.
Install the exhaust hose (See Page16), turn the drainage nozzle to the CLOSE position, and check the drainage nozzle is covered with the stopcock.
Press the MODE button to select FAN mode.
1
COOL DEHUM FAN VENT
2
1 3
2
5 3
1
Press the POWER button to start operation.
2
• The red OPERATION lamp on the unit will light.
• The temperature cannot be set.
Press the FAN button to set the desired fan
3
speed.
QUIET LOW HIGH
TO TURN OFF
Press the POWER button again.
• The red OPERATION lamp on the unit will turn off.
VENTILATION MODE
In this mode, the air conditioner ventilates the air to outdoors.
Install the exhaust hose (See Page 16), turn the drainage nozzle to the CLOSE position, and check the drainage nozzle is covered with the stopcock.
Press the MODE button to select VENT mode.
1
COOL DEHUM FAN VENT
2
1 3
Press the POWER button to start operation.
2
2
• The red OPERATION lamp on the unit will light.
• The temperature cannot be set.
5
Press the FAN button to set the desired fan
3
3
speed.
• Although the louvers are closed and no air blows out into the room, the external ventilation fan speed changes.
1
QUIET LOW HIGH
4
TO TURN OFF
Press the POWER button again.
• The red OPERATION lamp on the unit will turn off.
E-22
TO CHANGE AIR FLOW DIRECTION
UP / DOWN AIR FLOW DIRECTION
Press the LOUVERS button on the re-
1
mote control.
• The horizontal louvers will swing continuously.
Press the LOUVERS button again when
2
the horizontal louvers are at the desired
1 2
Horizontal louvers
position.
• The horizontal louvers will stop moving.
• The adjusted position will be memorized and the same position will be set automatically when operated the next time.
NOTE
• During VENTILATION mode, UP/DOWN air flow direction cannot be changed.
ENGLISH
LEFT / RIGHT AIR FLOW DIRECTION
Hold the vertical louver as shown in the dia­gram and adjust the air flow direction.
Vertical louvers
CAUTION
Never attempt to adjust the horizontal louvers manually.
• Manual adjustment of the horizontal louvers can cause the unit to malfunction when the remote control is used for adjustment.
• When the horizontal louvers are positioned at the lowest position in the COOL or DEHUMIDIFICA­TION mode for an extended period of time, condensation may result.
Do not adjust the vertical louvers to the extreme left or right in the COOL mode with the fan speed set to "QUIET ( Condensation may form on the louvers.
)" for an extended period of time.
E-23
PLASMACLUSTER OPERATION
The Plasmacluster ion generator inside the air conditioner will release positive and negative Plasmacluster ions into the room. Approximately the same numbers of posi-
tive and negative ions are released into the air.
Press the PLASMACLUSTER button during
1
operation.
• The remote control will display “ ”.
• The blue PLASMACLUSTER lamp on the unit will light.
TO CANCEL
1
Press the PLASMACLUSTER button again.
• The PLASMACLUSTER lamp on the unit will turn off.
NOTES:
• Use of the PLASMACLUSTER function will be memo­rized and it will be activated the next time you turn on the air conditioner.
• To turn off the PLASMACLUSTER Lamp, press the LIGHTS button.
• PLASMACLUSTER operation cannot be set during VENTILATION mode.
E-24
MEGA COOL OPERATION
In this operation, the air conditioner fan works at extra high speed with a setting temperature of 59°F.
Press the MEGA COOL button during cooling
1
mode.
• The remote control will display " " .
• The temperature display will go off.
• The green MEGA COOL lamp on the unit will light.
TO CANCEL
Press the MEGA COOL button again.
1
NOTES:
• You cannot set the temperature or fan speed during MEGA COOL operation.
• The fan returns to the HIGH speed setting after the unit has run for 30 minutes in MEGA COOL mode.
• The extra high fan speed may automatically slow down to protect the unit.
• MEGA COOL operation is also cancelled when the mode is changed, or when the unit is turned off.
• The green MEGA COOL lamp on the unit will turn off.
ENGLISH
ONE-HOUR OFF TIMER
When the ONE-HOUR OFF TIMER is set, the unit will automatically turn off after one hour.
Press the 1hr OFF button.
1
• The remote control displays “ ”.
• The orange TIMER lamp on the unit will light.
• The unit will stop operating after one hour.
TO CANCEL
Press the CANCEL button.
• The orange TIMER lamp on the unit will turn off.
1
CANCEL
NOTES:
• The ONE-HOUR OFF TIMER operation has priority over ON TIMER and OFF TIMER operations.
• If the ONE-HOUR OFF TIMER is set while the unit is not operating, the unit will operate for an hour at the formerly set condition.
• If you wish to operate the unit for another hour before the ONE-HOUR OFF TIMER is activated, press the 1hr OFF TIMER button again during operation.
Alernatively, turn the unit off by pressing the POWER button.
• The red OPERATION lamp and the orange TIMER lamp on the unit will turn off.
E-25
TIMER OPERATION
OFF TIMER
The unit will turn off automatically according to your setting. Timer duration can be set from a minimum of half an hour (30 minutes) to a maximum of 12 hours. Up to 9.5 hours, you can set in half-hour (30-minutes) increments and from 10 to 12 hours, in 1-hour increments.
Point the remote control at the signal receiver win­dow on the unit.
Press the OFF TIMER button and set the time
1
as desired.
• The time setting will change as you press the button as follows.
0.5h 1.0h 1.5h 10h 11h 12h
Hold the button down to speed through the set­tings.
• The orange TIMER lamp on the unit will light.
1
• The unit will emit a beep when it receives the signal.
• The time setting will count down to show the re­maining time.
TO CANCEL TIMER
Press the CANCEL button.
• The orange TIMER lamp on the unit will turn off.
Display shown when you set the unit to turn off 2.5 hours later.
NOTES ON TIMER SETTING AND OPERATION
• The latest time setting will be memorized and will appear on the remote control display the next time you set the OFF TIMER or ON TIMER.
• The OFF TIMER and ON TIMER can not be set together. Only the most recent TIMER setting will be valid.
• While the ONE-HOUR OFF TIMER is set, the OFF TIMER and ON TIMER is settings are unavailable.
• If the ONE-HOUR OFF TIMER is set while the OFF TIMER or ON TIMER activated, the ON TIMER or OFF TIMER setting will be cancelled.
• If a power failure occurs while the OFF TIMER or ON TIMER is set, the TIMER setting will be cancelled and will not be retrieved even after the power is restored.
E-26
ON TIMER
The unit will turn on automatically according to your setting. Timer duration can be set from a minimum of half an hour (30 minutes) to a maximum of 12 hours. Up to 9.5 hours, you can set in half-hour (30-minute) increments and from 10 to 12 hours, in 1-hour increments.
Point the remote control at the signal receiver win­dow on the unit.
Press the ON TIMER button.
1
• The time setting will change as you press the button as follows.
0.5h 1.0h 1.5h 10h 11h 12h
Hold the button down to speed through the set­tings.
1
Display shown when you set the unit to turn on 6.5 hours later.
• The orange TIMER lamp on the unit will light.
• The unit will emit a beep when it receives the signal.
• The time setting will count down to show the re­maining time.
Select the mode, temperature, fan speed setting and PLASMACLUSTER operation as desired.
• When the temperature is set with the ON TIMER, the temperature will show in the display for 5 sec­onds and then return to the time display.
• If you do not change the setting, the unit will operate using the most recent setting.
TO CANCEL TIMER
ENGLISH
Press the CANCEL button.
• The orange TIMER lamp on the unit will turn off.
E-27
Loading...
+ 67 hidden pages