LASER PRINTER : JX-8200
No. : CLE-062
CHANGE CARRIED OUT IN THE SCREWS AND THE
METAL PLATE OF THE BOX COVER OF THE ICU.
1.Model Name: JX-8200 (for all market destinations).
2.General: The attachment location became deformed when the plate on the ICU box side and the
MB fixing plate were attached with the previously used screws. As a measure to
alleviate this problem, a change has been carried out in the screws. In accordance with
the change described above a change has also been carried out in the metal plate. The
addition of a tap has been carried out to the screw holes on the metal plate side, and a
change has been carried out in the material used.
3.Description: Screws: XHBSE30P08000 → LX-BZ0034GCZZ
(M3 × 8 S tight binding screws) → (ICU Box Screw 2)
ICU box side plate: LPLTM0200GCZ1 → LPLTM0200GCZ2
MB fixing plate: LFIX-0004GCZ1 → LFIX-0004GCZ2
4.Action: From 1998 March production.
SHARP CORPORATION Reprography Division
1/2
Green
C
(Figure showing the detail of the changed portions)
Binding screw
(LPLTM0200GCZ1)
ICU box side plate
If the screw is
tightened this
Changed
The step screw has no groove
in this portion and so the
metal plate does not bend.
Figure of the screw section
portion bends.
Step screw
Added tap
(LFIX-0004GCZ1)
MB fixing plate
Of the 8 screws shown in the figure, 5 have been
changed from XHBSE30P08000 to LX-BZ0034GCZZ.
A tap has been added to the screw holes on the
metal plate side.
2/2
Ref.
Model
No.
JX-8200 All
<Interchange>
1. Interchangeable. 4. Not interchangeable.
2. Current type can be used in place of new type.
3. Current type cannot be used in place of new type.
Parts marked with " " is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
Version P/G No.
name
3 -8
3 -3
3 -5
New type cannot be used in place of current type.
New type can be used in place of current type.
Current parts New parts
Parts code Parts code
XHBSE30P08000 LX-BZ0034GCZZ AD Screw
LPLTM0200GCZ1 LPLTM0200GCZ2 AR ICU BOX side plate
LFIX-0004GCZ1 LFIX-0004GCZ2 AQ MB fixing plate
Price
rank
5. Interchangeable if replaced with same types of
related parts in use.
6. Others.
Parts name
Effec-
tive
time
'98/3
∗ Only the 5 screws of the ICU box have been changed.
Inter-
change-
ability
Note
∗