Sharp Carousel RK-42S24, Carousel RK-51K30, Carousel RK-51S27, Carousel RK-51W30, Carousel RK-51S30 Installation Instructions Manual

®
INSTALLATION INSTRUCTIONS
For Sharp Carousel
®
Built-in Kit Models RK-42S24, RK-51S27, RK-51K30, RK-51S30 or RK-51W30.
THIS KIT IS UL APPROVED TO ALLOW CERTAIN MICROWAVE OVENS TO BE INSTALLED ABOVE CERTAIN CONVENTIONAL/CONVECTION WALL OVENS. PLEASE SEE THE OPERATION MANUAL REGARDING APPROVED BUILT-IN APPLICATIONS.
IMPORTANT:
This Built-in Kit is designed for and approved only for those Sharp Microwav e Ovens specifying Built-In Kit RK-42S24, RK-51S27, RK-51K30, RK-51S30 or RK-51W30 on the rating label on the left side wall of the oven cavity.
The cabinet or wall opening must be within the following dimensions:
RK-42S24 HEIGHT : 15
WIDTH : 22 DEPTH : minimum 19
*RK-51S27, *RK-51K30, HEIGHT : 16 *RK-51S30 & *RK-51W30 WIDTH : 24
DEPTH : minimum 20"
* IF YOUR LOWER CONVENTIONAL OVEN IS NOT LISTED IN THE OPERATION MANUAL OF
THE MICROWAVE OVEN AS AN APPROVED MAKE AND MODEL, THEN DO NOT INSTALL THE MICROWAVE OVEN ABOVE IT OR IN ANY AREA WHERE HEAT AND STEAM ARE GENERATED; FOR EXAMPLE, NEXT TO OR ABOVE A CONVENTIONAL RANGE.
S= Stainless, K=Black, W=White
PLEASE READ THESE INSTRUCTIONS THOROUGHLY BEFORE BEGINNING INSTALLATION!
Be sure to DISCONNECT THE PLUG of the microwave oven from the
electrical outlet before installing the Built-in Kit. Remove the Carousel turntable from the oven cavity.
Because the kit includes metal par ts, due caution should be used in
handling and installation to avoid the possibility of injury.
11
/16" to 16"
1
/16" to 22 3/8"
1
/4"
3
/4" to 17"
3
/8" to 24 11/16"
NO. PART NAME QTY
PART CODE
1 FRAME ASSEMBLY 1
S24 - FDECAB015MRY0 S27 - FDECAB008MRY0 S30 - FDECAB018MRY0 K30 - FDECAB019MRY0 W30 - FDECAB020MRY0
2 EXHAUST DUCT ASSEMBLY 1
S24 - FDUC-B019MRK0 S27 - FDUC-B032MRK0 S30 - FDUC-B032MRK0 K30 - FDUC-B032MRK0 W30 - FDUC-B032MRK0
3 POWER SUPPLY CORD 1
BOX ASSEMBLY FCOVHB004MRK0
4 REAR DUCT 1
PDUC-B072MRP0
5 SCREW A 3
XCTSD40P10000
6 SCREW B 2
XTTSD40P30000
7 SCREW C 4
S24 - LX-CZB012MRE0 S27 - LX-CZB012MRE0 S30 - LX-CZB012MRE0 K30 - LX-CZB014MRE0 W30 - LX-CZB015MRE0
1
4
5
2
6
1
3
7
STEP 1 CABINET OR WALL OPENING
The opening in the wall or cabinet must be within the following dimensions:
RK-42S24:
*RK-51S27, *RK-51K30, *RK-51S30 & *RK-51W30
Outlet should NOT be in the shaded area as indicated on Sketch 1.
NOTE 1: If the dimension of DEPTH (C) is more than
21", the outlet location may be any area on the rear wall.
NOTE 2: The floor of the opening should be constructed
of plywood strong enough to support the weight of the oven and floor load (about 100 pounds). The floor should be level for proper operation of the oven. Be sure to check the local building code as it may require that the opening be enclosed with sides, ceiling and rear partition. The proper functioning of the oven does not require the enclosure.
HEIGHT : 15 WIDTH : 22 DEPTH : minimum 19
HEIGHT : 16 3/4" to 17" WIDTH : 24 DEPTH : minimum 20"
11
/16" to 16"
1
/16" to 22 3/8"
1
3
/8" to 24 11/16"
/4"
6"
4"
A
4"
B
C
Sketch 1
STEP 2 EXHAUST DUCT ASSEMBLY INSTALLATION
1. Place the EXHAUST DUCT ASSEMBLY in the
opening. When the EXHAUST DUCT ASSEMBLY is in the opening correctly, its flanges will be tightly against the lower edge of the opening. See Sketch 2.
2. Secure the EXHAUST DUCT ASSEMBLY with two
SCREWS B. See Sketch 2.
SCREW B
EXHAUST
DUCT ASSEMBLY
SCREW B
Sketch 2
2
Loading...