1. CHANGE IN THE OUTER DIAMETER OF THE PAPER DELIVERY LOCK SHAFT CARRIED OUT AS A MEASURE TO IMPROVE PRODUCTIVITY.
2. MEASURE TO ALLEVIATE PROBLEMS OF LOOSENING SCREWS CAUSED BY THERMAL CONTRACTIONS.
3. MEASURE TO IMPROVE PROBLEMS OF NOISE.
No. : ARE-119
1. Change in the outer diameter of the paper delivery lock shaft carried out as a measure to improve productivity.
1.Model Name: AR-280/285/335
used in the 2-bin paper delivery reversion unit of the models listed above. The diameter of the lock shaft has been changed from ø 8 to ø 6. This action has been carried out as a measure to improve productivity. Furthermore, in accordance with the change described above, a change has been carried out in the protect tube and the lock release lever, as well as the lock release lever fixing screw.
3.Action: From the 1st lot of 1998 September production.
2. Measure to alleviate problems of loosening screws caused by thermal contractions.
1.Model Name: AR-280/285/335
2.General: There have been problems of loosening screws caused by thermal contracting of the
plastic inside the fusing units of the models listed above. As a measure to alleviate these problems, a change has been carried out in the screws. Please refer to the figure provided for details concerning the locations of the changes described above.