SHARP ARE114 Technical Report

DIGITAL COPIER : AR-280
Date
:
Oct. 1, 1998
No. : ARE-114
E7-03 / E7-11 TROUBLES
1.Model Name: AR-280/285/335
2.General: An E7-03 or an E7-11 trouble may occur due to the vibration generated from the HDD
(Hard Disk). The following measures have been taken to correct the problems.
3.Description: E7-03 TROUBLE
Due to the vibration created by the HDD (Hard Disk) , a scanning failure occurs and it sometimes leads a machine to show an E7-03 trouble. Although such a scanning failure is rare to occur. As a measure to correct the problem, the HDD Protective Sheet has been added to the back of the Dark Box B (PG5-4) to alleviate the vibration generated by the HDD.
4.Action: From August 1998 production.
SHARP CORPORATION Reprography Division
1/2
Green
C
5.Description: E7-11 TROUBLE
Due to the vibrations generated by the HDD, the Dark Box Cover A (PG5-11) and the Dark Box Cover B (PG5-4), the CCD PWB harness FFC1/FFC2 (PG5-15,16) become contacted poorly. It then causes an E7-11 trouble in some rare cases. In order to correct the problem, the method of fitting the CCD PWB harness FFC1/FFC2 has been changed as described in the diagram below.
[Current]
6.Action: From middle of July 1998 production.
Ref.
Model
No.
AR-280 AR-285 AR-335
<Interchange>
1. Interchangeable. 4. Not interchangeable.
2. Current type can be used in place of new type.
3. Current type cannot be used in place of new type.
Parts marked with " " is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
Version P/G No.
name
All ---- ---- PSHEZ4685FCZZ AG
New type cannot be used in place of current type.
New type can be used in place of current type.
Current parts New parts
Parts code Parts code
[New]
Effec-
Price
5. Interchangeable if replaced with same types of related parts in use.
6. Others.
Parts name
rank
HDD protective sheet
tive
time
'98/8
Inter-
change-
ability
Note
2/2
Loading...