SHARP ARE073 Technical Report

DIGITAL COPIER : AR-5132
Date
:
Jan. 19, 1998
1. MEASURE TO STABILIZE THE RETURN OF THE PPD1 ACTUATOR.
2. MEASURE TO ALLEVIATE PROBLEMS OF DIAGONAL FEEDING OF THE ORIGINAL DOCUMENTS IN THE ADF.
3. CHANGE IN THE ATTACHMENT SCREWS OF THE FAN ATTACHMENT BASE PLATE CARRIED OUT AS A MEASURE TO IMPROVE OPERATIONABILITY.
4. CHANGE IN THE PART CODE CARRIED OUT IN ACCORDANCE WITH A CHANGE IN THE MAKER (ACTION CARRIED OUT AS A MEASURE TO IMPROVE PRODUCTIVITY).
No. : ARE-073
1. Measure to stabilize the return of the PPD1 actuator.
2.General: A change has been carried out in the load of the pawl spring. This action has been
carried out as a measure to stabilize the return of the PPD1 actuator in the transport DV guide unit.
3.Action: Running change from 1997 September production.
2. Measure to alleviate problems of diagonal feeding of the original documents in the ADF.
2.General: There have been problems of diagonal feeding of original documents during copy
operations using the ADF. As a measure to alleviate this problem, a change has been carried out in the ADF attachment step screws of the rear cabinet upper.
3.Action: From the 1st lot of 1997 November production.
SHARP CORPORATION Reprography Division
1/3
Green
C
3. Change in the attachment screws of the fan attachment base plate carried out as a measure to improve operationability.
2.General: A change has been carried out in the attachment screws of the fan attachment base
plate. This action has been carried out as a measure to improve operationability.
Chenged screws
3.Action: Running change from 1997 November production.
4. Change in the part code carried out in accordance with a change in the maker (action carried out as a measure to improve productivity).
2.General: A change was carried out in the maker of a portion of the outer case. In accordance
with this change a change has also been carried out in the part code.
3.Action: From 1997 December production.
2/3
Loading...
+ 1 hidden pages