Sharp AH-A07CR, AH-A09CR, AH-A12CR, AY-A07CR, AY-A09CR Operating Manual

...
R
AY-A07CR AY-A09CR AY-A12CR AH-A07CR AH-A09CR AH-A12CR
SPLIT TYPE ROOM AIR CONDITIONER
• Uses ozone layer friendly refrigerant R-410A.
Verwendet das die Ozonschicht schonende Kühlmittel R-410A.
Utilise un réfrigérant qui n’attaque pas la couche d’ozone, le R-410A.
Utiliza refrigerante R-410A que no daña la capa de ozono.
Utilizza il refrigerante R –410A che non danneggia il buco nell’ozono.
Usa refrigerante R-410A amigo da camada de ozono.
Χρησιµοποιεί ψυκτικ R-410A αβλαβές για το στρώµα του ζοντος.
Gebruikt de ozon-vriendelijke koelvloeistof R-410A.
INDOOR UNIT ZIMMERGERÄT UNIT INTERIEURE UNIDAD INTERIOR UNITA' INTERNA UNIDADE INTERIOR
ΕΣΩΤΕΡΙΚΗ ΣΥΣΚΕΥΗ
BINNEN-UNIT
AY-A07CR AY-A09CR AY-A12CR AH-A07CR AH-A09CR AH-A12CR
OUTDOOR UNIT AUSSENGERÄT UNIT EXTERIEURE UNIDAD EXTERIOR UNITA' ESTERNA UNIDADE EXTERIOR
ΕΞΩΤΕΡΙΚΗ ΣΥΣΚΕΥΗ
BUITEN-UNIT
AE- A07CR AE- A09CR AE- A12CR AU-A 0 7CR AU-A 0 9CR AU-A 1 2CR
ZWEITEILIGES KLIMAGERÄT
CLIMATISEUR INDIVIDUEL EN DEUX PARTIES
ACONDICIONADOR DE AIRE DE DOBLE SERVICIO
CONDIZIONATORE D'ARIA DA CAMERA TIPO SPLIT
AR CONDICIONADO DE DUAS UNIDADES
ΑΙΡΚΟΝΤΙΣΙΟΝ ∆ΩΜΑΤΙΟΥ
ΤΥΠΟΥ SPLIT
КОМНАТНЫЙ КОНДИЦИОНЕР ДВУБЛОЧНОГО ТИПА
OPERATION MANUAL BEDIENUNGSANLEITUNG NOTICE D'UTILISATION MANUAL DE INSTRUCCIONES MANUALE DI ISTRUZIONE MANUAL DE INSTRUÇÕES
ΕΓΧΕΙΡΙ∆ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ
GEBRUIKSAANWIJZING
ENGLISH
DEUTSCH
FRANÇAIS
ESPAÑOL
ITALIANO
PORTUGUÊS
ΕΛΛΗΝΙΚΑ
NEDERLANDS
ENGLISH
Thank you for purchasing a SHARP air conditioner. Please read this manual carefully before operating the product.
CONTENTS
• PRECAUTIONS ...........................................E-1
• ADDITIONAL NOTES ON OPERATION .....E-3
• TIPS ON SAVING ENERGY........................E-3
• PART NAMES..............................................E-4
• USING THE REMOTE CONTROL ..............E-6
• BASIC OPERATION ....................................E-8
• ADJUSTING THE AIR FLOW DIRECTION .E-10
• ONE-HOUR OFF TIMER .................... E-11
• TIMER OPERATION........................... E-12
• AUXILIARY MODE ............................. E-14
• OPTION KIT........................................ E-14
• MAINTENANCE .................................. E-15
• BEFORE CALLING FOR SERVICE ... E-16
PRECAUTIONS
WARNINGS FOR USE
Do not pull or deform the power supply cord. Pulling and misuse of the power supply cord
1
can result in damage to the unit and cause electrical shock. Be careful not to expose your body directly to the outlet air for a long time. It may affect
2
your physical conditions. When using the air conditioner for infants, children, elderly, bedridden, or disabled people
3
make sure the room temperature is suitable for those in the room. Never insert objects into the unit. Inserting objects can result in injury due to the high
4
speed rotation of internal fans.
ENGLISH
Ground the air conditioner without fail. Do not connect the grounding wire to gas pipe,
5
water pipe, lightning rod or telephone grounding wire. Incomplete grounding may cause electric shock.
If anything is abnormal with the air conditioner (ex. a burning smell), stop the operation
6
immediately and turn the circuit breaker OFF. Follow local rules and regulations for power supply cord cabling. Improper cable
7
connection can cause the power supply cord, plug and the electrical outlet to overheat and cause fire.
Use only the manufacture-specified power cord for replacement. Replacement should be
8
performed by a qualified technician or a service person.
WARNINGS FOR INSTALLATION / REMOVAL / REPAIR
•Do not attempt to install/remove/repair the unit by yourself. Incorrect work will cause electric shock, water leak, fire etc. Consult your dealer or other qualified service personnel for the installation/removal/repair of the unit.
This equipment complies with the requirements of Directives 89/336/EEC and 73/23/ EEC as amended by 93/68/EEC.
E-1
PRECAUTIONS
CAUTIONS FOR USE
Open a window or door periodically to ventilate the room, especially when using gas
1
appliances. Insufficient ventilation may cause oxygen shortage. Do not operate the buttons with wet hand. It may cause electric shock.
2
For safety, turn the circuit breaker off when not using the unit for an extended period of
3
time. Check the outdoor unit mounting rack periodically for wear and to make sure it is firmly
4
in place. Do not put anything on the outdoor unit nor step on it. The object or the person may fall
5
down or drop, causing injury. This unit is designed for residential use. Do not use for other applications such as in a
6
kennel or greenhouse to raise animals or grow plants. Do not place a vessel with water on the unit. If water penetrates into the unit, electrical
7
insulations may deteriorate and cause electric shock. Do not block the air inlets nor outlets of the unit. It may cause insufficient performance
8
or troubles. Be sure to stop the operation and turn the circuit breaker off before performing any
9
maintenance or cleaning. A fan is rotating inside the unit and you may get injured. Do not splash or pour water directly on the unit. Water can cause electrical shock or
10
equipment damage. This appliance is not intended for use by young children or infirm persons without
11
supervision. Young children should be supervised to ensure that they do not play with the appliance.
CAUTIONS FOR LOCATION / INSTALLATION
• Make sure to connect the air conditioner to power supply of the rated voltage and frequency.
Use of a power supply with improper voltage and frequency can result in equipment damage and possible fire.
• Do not install the unit in a place where inflammable gas may leak. It may cause fire. Install the unit in a place with minimal dust, fumes and moisture in the air.
•Arrange the drain hose to ensure smooth drainage. Insufficient drainage may cause wetting of the room, furniture etc.
•Make sure a leak breaker or a circuit breaker is installed, depending on the installation location, to avoid electrical shock.
E-2
ADDITIONAL NOTES ON OPERATION
OPERATING TEMPERATURE RANGE
INDOOR TEMP. OUTDOOR TEMP.
COOLING
HEATING
(AY-A07CR/AY-A09CR/ AY-A12CR only)
D.B. = Dry-bulb W.B. = Wet-bulb
upper limit
lower limit
upper limit
lower limit
32˚C D.B. 43˚C D.B. 23˚C W.B. -
21˚C D.B. 21˚C D.B. 15˚C W.B. -
27˚C D.B. 24˚C D.B.
- 18˚C W.B. 20˚C D.B. -8.5˚C D.B.
- -9.5˚C W.B.
WHEN POWER FAILURE OCCURS
This air conditioner has a memory function to store settings when a power failure occurs. After power recovery, the unit will automatically re-start in the same settings which were active before the power failure, except for timer settings. If the timers were set before a power failure, they will need to be re-set after power recovery.
NOTES FOR MODELS AY-A07CR/AY-A09CR/AY-A12CR
PREHEATING FUNCTION
In the HEAT operation, the indoor fan may not start for two to five minutes after the unit is turned on to prevent cold air from blowing out of the unit.
DE-ICING FUNCTION
• When ice forms on the heat exchanger in the outdoor unit during the HEAT operation, an automatic de-icer provides heat for about 5 to 10 minutes to remove the ice. During de-icing, the inside and outside fans stop operating.
• After de-icing is completed, the unit automatically resumes operation in the HEAT mode.
• The built-in protective device may prevent the unit from operating when used out of this range.
• Condensation may form on the air outlet if the unit operates continu­ously in the COOL or DRY mode when humid­ity is over 80 percent.
ENGLISH
HEATING EFFICIENCY
• The unit employs a heat pump that draws heat from the outside air and releases it into the room. The outside air temperature therefore greatly affects the heating efficiency.
• If the heating efficiency is reduced due to low outside temperatures, use an additional heater.
• It takes time to warm up and heat the entire room because of the forced air circulation system.
TIPS ON SAVING ENERGY
Below are some simple ways to save energy when you use your air conditioner.
SET THE CORRECT TEMPERATURE
• Setting the thermostat 1°C higher than the desired temperature in the COOL mode (and 2°C lower in the HEAT mode with models AY-A07CR/AY-A09CR/AY-A12CR) will save approximately 10 percent in power consumption.
• Setting the temperature lower than necessary during cooling operation will result in increased power consumption.
BLOCK DIRECT SUNLIGHT AND PREVENT DRAFTS
• Blocking direct sunlight during cooling operation will reduce power consumption.
• Close the windows and doors during cooling opeation (and heating operation with models AY-A07CR/AY­A09CR/AY-A12CR).
SET PROPER AIR FLOW DIRECTION TO OBTAIN THE BEST AIR CIRCULATION
KEEP FILTER CLEAN TO ENSURE THE MOST EFFICIENT OPERATION MAKE MOST OF THE TIMER OFF FUNCTION DISCONNECT THE POWER CORD WHEN THE UNIT IS NOT USED FOR AN
EXTENDED PERIOD OF TIME
• The indoor unit still consumes a small amount of power when it is not operating.
E-3
PART NAMES
INDOOR UNIT
1
1 Inlet (Air)
2
3
4
5
6
7
8
9
0
q
w e r t
2 Open Panel 3 Air Filters 4 AUX. Button 5 RECEIVER Window 6 Power Supply Cord 7 Indicator Panel 8 Vertical Adjustment Louvres 9 Horizontal Adjustment Louvres 0 Outlet (Air) q Remote Control
w
AUTO FAN SPEED Lamp
e FAN SPEED Lamp (green )
r TIMER Lamp (orange ) t OPERATION Lamp (red )
(green )
OUTDOOR UNIT
AE-A09CR/AE-A12CR AU-A09CR/AU-A12CR
NOTE: Actual units might vary slightly from those shown above.
y
u
i
AE-A07CR AU-A07CR
o
E-4
y Inlet(Air) u Refrigerant Tube and
Interconnecting Cord
i Drainage Hose o Outlet(Air)
y
u
i
o