SHARP 66DW18H, 70DW15S, 70DW15SN, 70DW18S, 76DW18H Service manual & schematics

...
Page 1

SHARP 66DW -18H

General Information

Also Covers
76DW-18H
CW-100 Chassis

Recommended Safety Parts

Item Part No. Description
VB66ESF0244*N C.R.T. 28” 16:9 66DW18H CT VB76ESF3144*N C.R.T. 32 16:9 76DW18H **
RCILGO41 7BMZZ Degaussing Coil 28” 16:9 66DW18H AX RCILGO41 8BMZZ Degaussing Coil 32” 16:9 76DW18H
IC 0701 RH-FXO1O6BMZZ M0C8106SR2V AD PR 0701 RMPTPOO28CEZZ P.T.C. AG L 0701 RCILF0154CEZZ Coil AQ L 0702 RCILP0110CEZZ 3.3uH AD L 0703 RCILP0110CEZZ 3.3uH AD T 0601 RTRNF2046BMZZ F.B.T. 66DW18H BK T 0601 RTRNF2045BMZZ F.B.T. 76DW18H BK T 0602 RTRNZ0553BMZZ Focus Transformer 76DW18H AU T 0701 RTRNZ0552BMZZ Chopper AX C 0701 RC-KZ0029CEZZ 0.01250V Ceramic AC C 0702 RC-FZO16OBMZZ 0.47275V Mylar AF C 0717 RC-KZO156CEZZ 13300p 4KV Ceramic AD R 0721 VRC-UA2HG825K 8.2M 1/2W Solid AA R 0722 VRC-UA2HG825K 8.2M 1/2W Solid AA F 0601 QFS-J2521CEZZ Fuse 2.5A 125V AD F 0602 QFS-J2521CEZZ Fuse 25A 125V AD F 0702 QFS-J2521CEZZ Fuse 2.5A 125V AD F 0703 QFS-J2521CEZZ Fuse 2.5A 125V AD SC 1801 QSOCV0103BMZZ C.R.T. Socket 66DW18H AG SC 1801 QSOCV0936CEZZ C.R.T. Socket 76DW18H AM IC 6703 RH-FX0106BMZZ M0C8106SR2V AD IC 6704 RH-FX0106BMZZ M0C8106SR2V AD L 6701 RCILF0108BMZZ Main Filter AL F 6701 QFS-C3226CEZZ Fuse 3.15A 250V AE S 6701 QSW-P0600BMZZ Power Switch AL IC 7001 RH-FX0103BMZZ M0C8105SR2V AD T 70001 RTRNZ0548BMZZ Transformer AU
SERVICING OF HIGH VOLTAGE SYSTEM AND PICTURE TUBE
When servicing the high voltage system, remove static charge from it by connecting a 10 k ohm resistor in series with an insulated wire (such as test probe) between picture tube ground tag and high voltage lead. (AC line cord should be disconnected from AC outlet.)
1. Picture tube this receiver employs integral implosion protection.
2. Replace with tube of the same type number for continued safety.
3. Do not lift picture tube by the neck.
4. Handle the picture tube only when wearing shatterproof goggles and after discharging the high voltage completely.
X-RAY
This receiver is designed so that any X-Ray radiation is kept to an absolute minimun. Since certain malfunctions ar servicing may produce potentially hazardous radiation with prolonged exposure at close range, the following precau­tions should be observed:
1. When repairing the circuit, be sure not to increase the high voltage to more than 33.0 kV, (at beam 1800 uA) for the set.
2. To keep the set in a normal operation, be sure to make it function on 29.5kV± 1.5kV (at beam 1800 uA) in the case of the set. The set has been factory adjusted to the above mentioned high voltage. If there is a possibility that high voltage fluctuates as a result of the repairs, never forget to check for such high voltage after the work.
3. Do not substitute a picture tube with unau­thorized types or brands which may cause excess
RCILGO419BMZZ Rotation Coil 16:9
CACCB5007BMV0 AC Cord AU

Service Notes

X-ray radiation. BEFORE RETURNING THE RECEIVER
Before returning the receiver to the user, perform the following safety checks.
1. Inspect all lead insulation to make certain that leads are not pinched or that hardware is not lodged between the chassis and other metal parts in the receiver.
2. Inspect all protective devices such as non­metallic control knobs, insulating fishpapers, cabinet backs, adjustment and compartment covers or shields, insolation resistor-capacity networks, mechanical insulators etc.
All the adjustments required for this chasis will be done in Service Mode, except G2, IF PLL (AFT) and RFAGC.
• G2 ADJUSTMENT
1. Receive cross hatch pattern signal.
2. Set contrast to 80/100 and brightness to 40/
100.
3. Connect the oscilloscope to the red cathode and adjust G2 to read 150V on the sensor pulse as in the following figure:

Service Adjustments

NOTE:
Osciloscope should be adjustated for vertical TV field trigger and synchronized with video signal.
• IF PLL ADJUSTMENT (AFT)
1. Disconnect antenna signal
2. Connect the output of SSG (Standard Signal Generator) to the tuner IF output terminal.
• SSG output: 38.9 MHz (CW) ± 5 kHz
• SSG output level: approx. 90 dBuV
• Probe: Direct
3. Connect the digital voltmeter to pin 11 of IC
201.
4. Adjust the AFT coil (L 205) to obtain 4.5VDc on voltmeter.
• RF AGC ADJUSTMENT
1. Receive “COLOUR BAR” signal (UHF).
• signal strength: 57 dBuV
2. Connect DC voltmeter to Test Point J91 (RF AGC).
3. Set AGC control (R224) to maximum position (memory).
4. Adjust R224 to obtain voltage of 0.1V below maximum voltage (step 3).
• SERVICE MODE FUNCTION
This mode function is provided to assist with the settings of those adjustment that may vary from one Picture Tube to another, or between models. In order to use the Service Mode
1. Connect Test Pattern signal to antenna terminal. Set to full mode screen by wide button
2. Press main switch to “OFF”.
3. Press volume-down and channel-up buttons and main switch to “ON” simultaneously.
4. Service mode is now entered.
The required adjustments can then be made from the Remote Control Unit. The only buttons required are the following: Up/Down-channel for movement in adjustment options menu; Up/Down-volume are used to carry out an adjustment in said menu; ON/OFF is used to memorize a new adjustment.
Adjustment menu is as follows:
- SERVICE SOFTWARE
- HORIZONTAL SHIFT
- EAST WEST WIDTH
- PIN PHASE
- PIN AMP
- UPPER CORNER CORRECTION
- LOWER CORNER CORRECTION
- VERTICAL LINEARITY
- VERTICAL ANGLE
- VERTICAL BOW
- VERTICAL AMPLITUDE
- S CORRECTION
- VERTICAL SHIFT
- RED GAIN
- GREEN GAIN
- BLUE GAIN
- RED CUT OFF
- GREEN CUT OFF
- BLUE CUT OFF
- ALTER NVM PAG
- ALTER NVM POS
- ALTER NVM VAL
- TELETEXT MIX MODE CONTRAST
- TELETEXT CONTRAST
- OSD CONTRAST
- DVCO ADJUSTMENT (ONLY PAL)
- DVCO ADJUSTMENT (ONLY NTSC)
- LUMA CHROMA DELAY
- OPC VALUE
- AUTOINST ALLATION ON/OFF
To exit service mode, press main switch to off.
Adjustment Note:
The procedure for making adjustments to horizontal coyrections are as follows:
- Adjust HORIZONTAL SHIFT
- Adjust E-W WIDTH
- Adjust PIN PHASE
- Adjust PIN AMPLITUDE
- Adjust UPPER CORNER CORRECTION
- Adjust LOWER CORNER CORRECTION The procedure for making adjustments to
vertical corrections is as follows:
- Adjust VERTICAL AMPLITUDE
- Adjust S-CORRECTION
- Adjust VERTICAL SHIFT
- Adjust VERTICAL LINEARITY
- Adjust VERTICAL ANGLE
- Adjust VERTICAL BOW
1- HORIZONTAL SHIFT
a) Receive Philips pattern signal. b) When volume-up button is pressed, picture
moves to the left.
c) When volume-down button in pressed, picture
moves to the right.
d) Adjust the horizontal location to obtain picture
centering (fig. 1).
2- E-W WIDTH
a) Receive Philips pattern signal. b) When volume-up button is pressed, horizontal
scanning increases.
c) When volume-down button is pressed,
horizontal scanning decreases.
d) Adjust the horizontal amplitude to obtain 8%
overscan (fig. 2).
3- PIN PHASE
a) Receive Philips pattern signal. b) When volume-up button is pressed, slide
pincushion changes.
c) When volume-down button is pressed, slide
pincushion changes.
d) Adjust the PIN PHASE to obtain condition as
in (fig. 3).
4- PIN AMPLITUDE
a) Receive Philips pattern signal. b) When volume-up button is pressed, slide
pincushion changes from pincushion to barrel shape.
c) When volume-down button is pressed, slide
pincushion changes from barrel to pincushion shape.
d) Adjust the PIN AMPLITUDE to obtain
condition as in (fig. 4).
Fig. 1
Fig. 2
Fig. 3
Fig. 4 5- UPPER CORNER CORRECTION
a) Receive Philips pattern signal. b) When volume-up button is pressed, slide
pincushion changes from pincushion to barrel shape.
c) When volume-down is pressed, slide
pincushion changes from barrel to pincushion shape.
d) Adjust the UPPER CORNER CORRECTION
to obtain condition as in (fig. 5).
6- LOWER CORNER CORRECTION
a) Receive Philips pattern signal. b) When volume-up button is pressed, slide
pincushion changes from pincushion to barrel shape.
c) When volume-down button is pressed, slide
pincushion changes from barrel to pincushion shape.
d) Adjust the LOWER CORNER CORRECTION
to obtain condition as in (fig. 6).
7- VERTICAL LINEARITY
a) Receive Philips pattern signal. b) When volume-up button is pressed, upper
picture scanning decreases and lower picture scanning increase.
c) When volume-down button is pressed, upper
picture scanning increases and lower picture scanning decreases.
d) Adjust the vertical symmetry to obtain
symmetrical scanning between upper and lower picture (fig. 7).
8- VERTICAL ANGLE
a) Receive Philips pattern signal. b) When volume-up button is pressed, vertical
angle changes to the right.
c) When volume-down button is pressed,
vertical angle changes to the left.
d) Adjust the VERTICAL ANGLE to obtain
condition as in (fig. 8).
9- VERTICAL BOW
a) Receive Philips pattern signal. b) When volume-up button is pressed, vertical
bow changes to the right.
c) When volume-down button is pressed,
vertical bow changes to the left.
d) Adjust the VERTICAL BOW to obtain
condition as in (fig. 9).
10- VERTICAL AMPLITUDE
a) Receive Philips pattern signal. b) When volume-up button is pressed, vertical
size of picture increases.
c) When volume-down button is pressed,
vertical size of picture decreases.
d) Adjust the vertical size to obtain overscan
(fig. 10).
11- S-CORRECTION
a) Receive Philips pattern signal. b) When volume-up button is pressed, upper
and lower scanning decreases, and center scanning increases.
c) When volume-down button is pressed, upper
and lower scanning increases, and center scanning decreases.
d) Adjust the S-correction to obtain a balance
between upper, lower and center (fig. 11).
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11 12- VERTICAL SHIFT
a) Receive Philips pattern signal. b) When volume-up button is pressed, picture
moves up.
c) When volume-down button is pressed, picture
moves down.
d) Adjust the horizontal location to obtain picture
centering (fig. 12)
Fig. 12
Page 2
SHARP 66DW -18H

Adjustments Cont’d

1. RED CUT OFF / GREEN CUT OFF / BLUE CUT OFF
1.1 Adjust G2.
1.2 Tune a white card.
1.3 Adjust colour to minimum.
1.4 Position colourimeter in the center of screen.
1.5 Adjust brightness and contrast to obtain a luminance of 20 NITS.
1.6 Operate in Service Mode and select location RED CUT OFF/ GREEN CUT OFF/ BLUE CUT OFF, to obtain colour coordinates:
X = 0.297 ± 0.015 Y = 0.310±0.015
To increase press volume-up button and to decrease press volume-down button
RED CUT OFF alter “X’ coordinate GREEN CUT OFF alter “Y” coordinate BLUE CUT OFF alter “X” and “Y coordinate
1.7 The changes introduced can be memorized by pressing button (5 on TV set.
2. RED GAIN / GREEN GAIN / BLUE GAIN
2.1 Using brightness and contrast buttons, select a luminance of 110 NITS.
2.2 Operate again in Service Mode and select location RED GAIN / GREEN GAIN BLUE GAIN, to obtain colour coordinates:
Shows reading of detected illuminated value by O.P.C. (Optical Picture Control) to check function.
AUTO INSTALLATION OFF/ON
When ON is selected, the TV will perform the autoinstallation secuence as soon as service mode is removed.
PROTECTIONS CANCEL
a) Connect Test Pattern signal to antenna
terminal. b) Press main switch to OFF. c) Press volume-down and channel-up buttons
and main switch to ON simultaneously. d) “Service software Vxx.xx” appears on screen. c) Press main switch to OFF.
The End.
Aux Power Unit
Diagram
X = 0.297 ± 0.015 Y = 0.310 ± 0.015
To increase press volume-up button and to decrease press volume-down button
RED GAIN alter X coordinate GREEN GAIN alter ‘Y” coordinate BLUE GAIN alter “X” and “Y” coordinate
2.3 The changes introduced can be memorized by pressing button (1) on TV set.
2.4 Exit Service Mode and check colour coordinates “X” and ‘Y” at 20 and 110 NITS. It may be necessary to repeat procedure 1 and 2 of COLOUR ADJUSTMENT.
ACCESS TO NVM
Press CH UP to move in the following secuence: ALTER NVM PAG > ALTER NVM POS > ALTER NVM VAL to alter preseting adjustments, press up/down­volume buttons on ALTER NVM VAL. CAUTION: Do not change NVM VALUE to avoid risk of serious damages to TV set.
CONTRAST ADJUSTMENT
Up/Down-volume buttons are used to adjust the contrast of the following items:
-TELETEXT MIX MODE CONTRAST
-TELETEXT CONTRAST
-OSD CONTRAST

Terminal PCB’sDiagram

DVCO ADJUSTMENT
a) Receive Philips pattern signal. b) When Stand-by button is pressed (Remote
Control Unit), start automatically the adjust­ment.
LUMA CHROMA DELAY
a) Receive Philips pattern signal. b) When volume-up button is pressed, luma
phase delays.
c) When volume-down button is pressed,
chroma phase delays.
d) Adjust the Chroma-Luma delay.
OPC VALUE
Page 3
SHARP 66DW -18H

100 Hz Diagram

Page 4
SHARP 66DW -18H

Scart A/V Diagram

Page 5
SHARP 66DW -18H

CRT Base PCB Diagram

Front Control Diagram

Mother Board Diagram W aveforms

Page 6
Page 7
Page 8