SHARP 530UIB Service Manual

ELECTRONIC CASH REGISTER
INSTRUCTION MANUAL
MODEL
ER-A520 ER-A530
The above illustration shows the model ER-A520.
FCC Regulations state that any unauthorized changes or modifications to this equipment not expressly approved by the manufacturer could void the user's authority to operate this equipment. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harm­ful interference when the equipment is operated in a commercial environ­ment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
WARNING
CAUTION
The AC outlet shall be installed near the equipment and shall be easily accessible.
Please record below the model number and serial number, for easy reference, in case of loss or theft. These numbers are located on the right side of the unit. Space is provided for further pertinent data.
Model Number
Serial Number
Date of Purchase
Place of Purchase
FOR YOUR RECORDS

INTRODUCTION

Thank you very much for your purchase of the SHARP Electronic Cash Register, Model ER-A520/A530. Please read this manual carefully before operating your machine to gain a thorough understanding of the functions and features offered by this model ECR. Please keep this manual for future reference, it may help you if you encounter operational problems.

IMPORTANT

Install your register in a location that is not subject to direct radiation, unusual temperature changes,
high humidity or exposed to water sources.
Installation in such locations could cause damage to the cabinet and the electrical components.
The register should not be operated by an individual with wet hands. The water could seep into the interior of the register and cause component failure.
When cleaning your register, use a dry, soft cloth. Never use solvents, such as benzine and/or thinner. The use of such chemicals will lead to discoloration or deterioration of the cabinet.
The register plugs into any standard wall outlet (120V ±10% AC) which utilizes a dedicated ground
circuit.
Please note that other electrical devices on the same electrical circuit could cause the register to malfunction.
• If the register malfunctions, call your local dealer for service - do not try to repair the register yourself.
• For a complete electrical disconnection, the AC power cord must be removed from the wall outlet.
• Never disconnect the peripheral while the register remains plugged into the AC outlet.

PRECAUTION

This Electronic Cash Register has a built-in memory protection circuit which is supported by rechargeable batteries. It is important to know that all batteries will, in time, dissipate their charge even if not used. Therefore to insure an adequate charge in the protection circuit, and to prevent any possible loss of memory during or after installation, it is recommended that each unit be allowed to recharge for a period of 24 to 48 hours prior to and during use by the customer. In order to charge the batteries, the machine must be plugged in. This recharging precaution can prevent unnecessary equipment malfunctions or service calls.
1

CONTENTS

INTRODUCTION····················································································································································1 IMPORTANT··························································································································································1 PRECAUTION························································································································································1 CONTENTS····························································································································································2
EXTERNAL VIEW OF THE ER-A520····················································································································8
Front view···············································································································································8 Rear view················································································································································8
EXTERNAL VIEW OF THE ER-A530····················································································································9
Front view···············································································································································9 Rear view················································································································································9
PRINTER······························································································································································10 KEYBOARD·························································································································································11
1 ER-A520 standard keyboard layout·········································································································11 2 ER-A530 standard keyboard layout·········································································································13 3 Standard key number layout····················································································································15 4 Installing the keyboard sheet (ER-A530)·································································································16
KEYS AND SWITCHES·······································································································································17
1 Mode switch and mode keys ···················································································································17 2 Drawer lock key·······································································································································17 3 Printer cover lock key ······························································································································18 4 Cashier/Server code entry key ················································································································18 5 Receipt ON/OFF function ························································································································18
DISPLAYS ···························································································································································19
1 Operator display ······································································································································19 2 Customer display (Pop-up type)··············································································································19
PRIOR TO ENTRIES ···········································································································································20
1 Preparations for entries ···························································································································20 2 Power save mode····································································································································21 3 Error warning···········································································································································21
ENTRIES······························································································································································22
1 Item entries··············································································································································22
Single item entries································································································································22 Repeat entries ······································································································································23 Multiplication entries·····························································································································24 Successive multiplication entries··········································································································25 Split-pricing entries·······························································································································26 Single item cash sale (SICS)/single item finalize (SIF) entries·····························································27 Scale entries·········································································································································28 PLU level shift (for direct PLU) ·············································································································30 PLU/UPC price level shift ·····················································································································32 Set PLU entries ····································································································································33 Link PLU/UPC entries···························································································································34 Age verification (Birthday entry) ···········································································································34 Mix-and-match entries··························································································································35 Condiment entries (for PLUs)···············································································································35 Price inquiry (view) function (for PLU/UPCs)························································································36 UPC learning function···························································································································37 Price change function (for PLU/UPCs)·································································································38
2 Displaying and printing subtotals·············································································································40
Merchandise subtotal ···························································································································40
FOR THE OPERATOR
2
Taxable subtotal ···································································································································40 Including-tax subtotal (full subtotal)······································································································40 Food stamp-eligible subtotal·················································································································40 Tray subtotal·········································································································································40 Eat-in subtotal·······································································································································40 Gasoline discount subtotal ···················································································································40
3 Finalization of transaction························································································································41
Cash or Check tendering······················································································································41 Mixed tendering (check + cash)············································································································41 Cash or Check sale that does not need any tender entry ····································································42 Charge (credit) sale······························································································································42 Mixed-tender sale (cash or check tendering + charge tendering) ························································42
4 Food stamp calculations··························································································································43
Food stamp tendering···························································································································43 Food stamp status shift ························································································································44
5 Tax calculations·······································································································································45
Automatic tax········································································································································45 Manual tax············································································································································45 Automatic-tax delete·····························································································································46 Tax status shift ·····································································································································47
6 Guest check (GLU/PBLU) ·······················································································································48
GLU/PBLU system ·······························································································································48 Deposit entries······································································································································51 Transferring guest checks out or in (Transfer-out/in) ···········································································52 Bill totalizing/bill transfer·······················································································································53 Bill separating·······································································································································54 Manual Previous Balance(PB) and Credit Balance(CB) entry······························································55
7 Auxiliary entries ·······································································································································57
Percent calculations (premium or discount) ·························································································57 Discount entries····································································································································58 Refund entries ······································································································································59 Return entries·······································································································································59 Refund sales mode·······························································································································60 Printing of non-add code numbers ·······································································································60 Gratuity·················································································································································61
8 Payment treatment ··································································································································62
Tip-in entries·········································································································································62 Tip editing·············································································································································63 Tip paid entries·····································································································································63 Currency conversion·····························································································································64 Received on account entries ················································································································65 Paid out entries·····································································································································65 No sale (exchange) ······························································································································65 Cashing a check···································································································································66 Bottle return··········································································································································66
9 Automatic sequencing key entries···········································································································66
10 WASTE mode··········································································································································67
CORRECTION ·····················································································································································68
1 Correction of the last entry (direct void)···································································································68 2 Correction of the next-to-last or earlier entries (indirect void)··································································68 3 Subtotal void············································································································································69 4 Correction of incorrect entries not handled by the direct or indirect void function···································69
CORRECTION AFTER FINALIZING A TRANSACTION (AFTER GENERATING A RECEIPT)························70 OVERRIDE ENTRIES··········································································································································71
OVERLAPPED CASHIER/SERVER ENTRY ······································································································72 SPECIAL PRINTING FUNCTIONS······················································································································73
1 Copy receipt printing································································································································73
3
2 Validation printing function (Slip printer)··································································································74 3 Bill printing···············································································································································74 4 Printing of the employee’s arrival and departure times (Slip printer)·······················································74 5 Printing of header and footer graphic logos·····························································································75 6 Remote printer send function ··················································································································75
TIME DISPLAY AND AUTOMATIC UPDATING OF THE DATE ········································································76
1 Time display ············································································································································76 2 Automatic updating of the date················································································································76
PRIOR TO PROGRAMMING·······························································································································77
1 Programming keyboard layout·················································································································77 2 How to program alphanumeric characters·······························································································78
Using character keys on the keyboard ·································································································78 Entering character codes······················································································································78
PROGRAMMING ·················································································································································80
Basic instructions··································································································································80 Preparations for programming··············································································································80
Direct Programming···········································································································································80
1 Setting the date and time·························································································································80
Date······················································································································································80 Time······················································································································································81
2 Programming for departments·················································································································81
Unit price ··············································································································································81 Functional selection······························································································································82
3 PLU/UPC programming···························································································································84
Unit price ··············································································································································84 Functional selection······························································································································85 Associated department·························································································································86
4 Programming for discount keys (
-
) ······································································································87 Discount amount ··································································································································87 Functional programming·······················································································································87
5 Programming for percent keys (
%
)········································································································88 Percent rate··········································································································································88 Functional programming·······················································································································89
6 Programming for conversion keys (
ç
) ··································································································90
Currency conversion rate ·····················································································································90
7 Programming for the
r, p
, and † keys ···························································································90
High amount lockout (HALO)················································································································90
8 Programming for the
a
, , ', and k keys···················································································91
High amount lockout (HALO) and function selection············································································91
9 Programming for the automatic tax calculation function··········································································93
The tax table (applicable to the add-on tax) ·························································································93
Job-Code-Based Programming ························································································································96
1 Setting the date and time·························································································································96
Setting the date (#2610)·······················································································································96 Setting the time (#2611) ·······················································································································96
2 Setting the register and consecutive numbers ························································································97
Setting the register number (#2612)·····································································································97 Setting the consecutive number (#2613)······························································································97
3 Programming for the automatic tax calculation function··········································································98
The tax table (#2710) ···························································································································98 The tax rate (#2711)···························································································································100 Doughnut tax exempt (for the Canadian tax system) (#2715)····························································101
4 Programming for departments···············································································································102
Functional programming 1 (#2110) ····································································································102
CA
FOR THE MANAGER
4
Functional programming 2 (#2111) ····································································································104 A limit amount (HALO) of entry (#2112) ·····························································································105 Item label (#2114)·······························································································································105 Unit price (#1110)·······························································································································106 Commission group assignment (#2115)·····························································································106 Group number (#2116)·······················································································································107 Group text (#2350) ·····························································································································107 Age limitation (#2180)·························································································································108 Print station assignment (#2118)········································································································108 Department key positioning (#2119)···································································································109 Color Video Monitor (CVM) control character (#2158) ·······································································109
5 PLU/UPC programming·························································································································110
Associated department (#1200, 2230, 1050) ·····················································································111 Unit prices (#1210, 1060) ···················································································································113 Base quantity (#1211, 1061) ··············································································································114 Functional programming 1 (#2210, 2231, 2060) ················································································114 Functional programming 2 (#2211, 2232, 2061) ················································································116 Item label (#2214, 2064)·····················································································································118 Commission groups (#2215, 2235, 2065) ··························································································119 Group number (#2216, 2066)·············································································································120 Group text (#2351) ·····························································································································120 Age limitation (#2280, 2236, 2081)·····································································································121 Stock quantity (#1222, 1220, 1221)····································································································122 Set PLU (#2221)·································································································································123 Mix-and-match table (#2217, 2225, 2067)··························································································124 PLU condiment table (#2222, #2223)·································································································125 Print station to PLU/UPC assignment (#2218, 2068) ·········································································127 Delete period for non-accessed UPC codes (#2029)·········································································128 Programming Non-PLU code format (#2025)·····················································································129 Link PLU/UPC link (#2220)·················································································································130 Programming of PLU levels and direct PLU keys (#2219) ·································································130 Item label for remote printer (#2244, 2094)························································································131 Color Video Monitor (CVM) control character (#2258, 2234, 2059) ···················································132
6 Programming for miscellaneous keys····································································································133
Rate (
%, ç
, commission, gratuity, , ) and discount (-) (#1310) ····································133 Gas discount unit price (#1311)··········································································································134 Currency description text (
ç
) (#2334)······························································································134
A limit amount (HALO) of entry (
-, †
(for manual tax), , , r, p) (#2312) ····················135
+/– sign, food stamp status and tax status (%, -, gratuity) (#2311)··············································136 Percent entry type (
%
) (#2310) ········································································································137
Item % or subtotal % selection (
%
) (#2315)·····················································································138
Percent rate limitation (
%
) (#2313)···································································································138
Vendor or store coupon selection (
-
) (#2316)·················································································139
7 Programming for the media keys···········································································································140
Functional programming 1 (#2320) ····································································································140 Functional programming 2 (#2326) ····································································································142 High amount lockout (HALO) for check cashing, check change, and cash in drawer (#2321)···········143 High amount lockout (HALO) of entry for media keys (#2322)···························································143 Print station assignment (#2328)········································································································144 CAT programming (#2330)·················································································································145
8 Programming of function text·················································································································146
Programming (#2314)·························································································································146 List of function texts····························································································································146
9 Server/Cashier programming ················································································································150
Server/Cashier code (#1400) ·············································································································150 Server/Cashier name (#1414) ············································································································150
CH TIPCATIP
CH TIPCATIP
5
Functional programming (#2410) ·······································································································151 GLU/PBLU code range assignment (#2411)······················································································151 Net sales % rate (#2413)····················································································································152
10 Programming various functions·············································································································152
Programming for optional feature selection (#2616) ··········································································152 Programming the parameter of the slip printer (#2615)······································································157 Setting the time limit for THE TILL TIMER
TM
(#2617) ·········································································158 Scale tare table (#2618) ·····················································································································158 Programming of logo messages (#2614) ···························································································159 Selection of X1/Z1 and X2/Z2 reports to be printed in the stacked report sequence (#2620)············160 Setting the time range for hourly reports (#2619)···············································································161 Programming of power save mode (#2689) ·······················································································161 Available GLU/PBLU codes (#2810) ··································································································162 Bill number (#2636) ····························································································································162 Functional programming for the printer (#2990)·················································································163 Editing guidance/error messages (#2641)··························································································163 Validation message (#2642)···············································································································165 Slip printer’s logo message (#2643)···································································································165 RS-232C channel assignment (#2690) ······························································································166 Barcode reader programming (#2691) ·······························································································167 Remote printer assignment (#2692)···································································································168 Second remote printer assignment (#3653) ·······················································································168 Remote printer name (#3654) ············································································································169 Print format for remote printer (#3655)·······························································································169 Chit receipt format (#3656)·················································································································170 RS-232C interface (#6110, 6111, 6112, 6113, 6115, 6212, 6213, 6220)···········································171 Programming the CAT interface (#7110, 7111, 7112, 7113, 7114, 7115, 7116)································173 Secret codes to control access to the PGM1 mode, X1/Z1 mode and X2/Z2 mode (#2630, 2631, 2632) ···························································································································175 Loading dynamic UPCs to the main UPC file (#2099)········································································175 Setting the AUTO key (#2900) ···········································································································176
11 TRAINING mode ···································································································································177 12 Reading stored programs······················································································································178
Program details and procedures for their reading ··············································································178 Sample printouts·································································································································180
13 Universal Product Code (UPC) or European Article Number (EAN) ·····················································188
UPC or EAN code·······························································································································188 Add-on code ·······································································································································189
READING (X) AND RESETTING (Z) OF SALES TOTALS···············································································190
1 Summary of reading (X) and resetting (Z) reports and the key operations to obtain the reports ··········190 2 Daily sales totals····································································································································195
General report ····································································································································195 Cashier/Server report ·························································································································199 Hourly report·······································································································································200 Full department report ·······················································································································201 Individual group total report on department························································································201 Full group total report on department ·································································································201 PLU/UPC report (by designated range or pick up list)········································································202 PLU/UPC report by associated department ·······················································································204 Individual group total report on PLU/UPC ··························································································204 Full group total report on PLU/UPC····································································································204 PLU/UPC zero sales report by department ························································································205 PLU/UPC price category report··········································································································205 PLU/UPC stock report (by designated range or pick up list) ······························································205 Commission sales report····················································································································205 GLU/PBLU report ·······························································································································206 GLU/PBLU report by cashier/server···································································································206
6
Closed GLU/PBLU report ···················································································································207 Closed GLU/PBLU report by cashier/server·······················································································208 Transaction report ······························································································································209 Tax report ···········································································································································209 Cash in drawer report·························································································································209 Dynamic UPC report (by designated range or pick up list)·································································210 Dynamic UPC report by associated department ················································································210 Dynamic UPC clear (by designated range or pick up list) ··································································210 Dynamic UPC clear by associated department··················································································210 X1/Z1 stacked report ··························································································································210 Deleting of non-accessed UPCs·········································································································211
3 Periodic consolidation····························································································································212
General Overview·······························································································································212 Daily net report ···································································································································212 X2/Z2 stacked report ··························································································································212
COMPULSORY CASH/CHECK DECLARATION······························································································213 OPERATOR MAINTENANCE ···························································································································215
1 In case of power failure ·························································································································215 2 In case of printer error ···························································································································215 3 Thermal printing·····································································································································215
Cautions in handling the printer··········································································································215 Cautions in handling the recording paper (thermal paper) ·································································216
4 Installing and removing the paper roll····································································································217
Recording paper specifications ··········································································································217 Installing the paper roll ·······················································································································217 Removing the paper roll ·····················································································································218
Removing a paper jam ·······················································································································220 5 Cleaning the print head ·························································································································221 6 Removing the till and the drawer···········································································································222 7 Opening the drawer by hand ·················································································································222 8 Before calling for service ·······················································································································223
Error message table ···························································································································223
LIST OF OPTIONS ············································································································································224 SPECIFICATIONS ·············································································································································225
7

EXTERNAL VIEW OF THE ER-A520

Front view

Rear view

8
Printer cover
Receipt paper
Journal window
Keyboard
Drawer
Drawer lock
Customer display (Pop-up type)
Operator display
Mode switch
Printer cover lock
(left side)
Rear cover
9

EXTERNAL VIEW OF THE ER-A530

Front view

Rear view

Printer cover
Receipt paper
Journal window
Keyboard
Drawer
Drawer lock
Customer display (Pop-up type)
Operator display
Mode switch
Printer cover lock
(left side)
Rear cover
10

PRINTER

The printer is a receipt/journal dual station type thermal printer which delivers fast, quiet and high quality printing. The average life of the printer is approximately 5 million lines.
When opening the printer cover, unlock the printer cover using the printer cover lock key, and lift up the cover as shown in the diagram to the right.
Your register is shipped with the print head release lever held in the up position by a white shipping retainer. Be sure to remove this retainer (see the figure at the right) and push down the print head release lever before you use the register.
Print head release lever
The print head can be lifted by the green lever on the right side of the printer. Pulling the lever forward, lifts the print head up. If the paper becomes jammed and you need to move the print head farther forward, you can pull the lever even further toward you and proceed with the removal of the jammed paper.
Do not attempt to remove the paper roll with the head in the down position. This may result in
damage to the printer and print head.
Note
Retainer
Printer lock keyPrinter cover
Paper roll location
Take-up spool
Paper chute
Print head release lever
11

KEYBOARD

All keys except the receipt paper feed and journal paper feed keys can be re-positioned. If you want to change the layout, please consult your authorized SHARP dealer.
0
9
RFND
VOID
00
CL
Numeric keys
Decimal point key
Clear key
Multiplication key
Refund key
Void key
Amount entry key
Cashier code entry key
PLU/UPC
AMT
CASH
#
RECEIPT
JOURNAL
Receipt paper feed key
Journal paper feed key
PLU/UPC key
INQ
PLU/UPC inquiry key
UPC price change key
PRICE CHANGE
201
Department keys
Automatic sequencing 1 and 2 keys
AUTO
1
AUTO
2
FS
SHIFT
Food stamp shift key
No-sale key
NS
TAX 1 shift key
TAX
Manual tax key
Merchandise subtotal key
RA
Received-on-account 1 key
PO
Paid-out 1 key
FOR
@
Previous balance key
PBLU
Final key
FINAL
New check key
NC
Discount 1 key
%1 %2
Percent 1 and 2 keys
TAX
SHIFT
MDSE
SBTL
Note
L
.
RCPT
NC AMT
5
INQ
AUTO
1
FS
SHIFT
PBLU
7 4 1
0
00
4
3
2
1
10
9
8
7
6
15
14
13
12
11
20
19
18
17
16
FS
TEND
CA/AT
CH1
CH2CHK
MDSE
SBTL
SBTL
AUTO
2
2
5 6
8 9
TAX
SHIFT
RFND
%2
#/TM
VOID
PLU/UPC
3
SLIP
RA
FINALCONV
PO TAX%1
CASH
#
@
FOR
PRICE
CHANGE
NS

ER-A520 standard keyboard layout

1
12
The following function keys can optionally be mounted in place of those shown in the figure of the
standard keyboard layout. For details, please consult your authorized SHARP dealer.
Optional keys
%3 %5
Percent 3 thru 5 keys Eat in 1 thru 3 keys
CONV2 CONV4
RA2
Received-on-account 2 key
PO2
Paid-out 2 key
SRVC
Service key
RETURN
Return key
Tray subtotal key
AUTO
3
TRAY SBTL
Transfer out key
TRANS
OUT
Transfer in key
TRANS
IN
Cash tip key
CA TIP
Charge tip key
CH TIP
AUTO
10
Automatic sequencing 3 thru 10 keys
Cash 2 thru 5 keys
Currency conversion 2 thru 4 keys
CA2 CA5
CH3 CH9
Charge 3 thru 9 keys
-
2
-
Discount 2 thru 5 keys
5
DEPT
#
Dept. number key
REPEAT
Repeat entry key
SCALE
L1
Scale entry key
PRINT
Validation print key
PLU level shift 1 thru 5 keys
Gasoline sales subtotal key
TIP
PAID
Tip paid key
DEPO
Deposit key
LEVEL
#
PLU level shift number key
RP
SEND
Remote printer send key
DEPO
RFND
Deposit refund key
GRT
EXEMPT
Gratuity exempt key
OPEN
TARE
Tare entry key
CHK2 CHK5
Check 2 through 5 keys
EAT IN1EAT IN
3
Tax 2 thru 4 shift keys
TAX2
SHIFT
TAX4
SHIFT
GAS
SBTL
Price shift number key
P-SHIFT
#
Cover count entry key
CV
CNT
L5
P1
Price level shift 1 thru 6 keys
P6
Note
#/TM
Non-add code/Date & time display key
Receipt print key
RCPT
Slip printer key
SLIP
Food stamp tender key
FS
TEND
CH1CH
2
Charge 1and 2 keys
CONV
Currency conversion key
CHK
Check 1 key
SBTL
Subtotal key
CA/AT
Cash/amount tendered key
13
The department and direct PLU keys may be expanded. If you require expansion of the department
or direct PLU keys, please contact your dealer.
All keys except the receipt paper feed and journal paper feed keys may be re-positioned. If you want to change the keyboard layout, please consult your dealer.
Please note that the price lookup/subdepartment/UPC key (
P
) and the previous balance key
() are shown as and
u
respectively in this manual.
0
9
RFND
RCPT
VOID
00
000
CL
Numeric keys
Decimal point key
Clear key
Multiplication key
Receipt print key
Refund key
Void key
PLU/
SUB
RECEIPT
JOURNAL
Receipt paper feed key
Journal paper feed key
Direct price lookup keys
FOR
@
Price lookup/subdepartment/ UPC key
1 100
PLU/ UPC
PBAL
Note
31
20
9
79
67
56
45
34
23
12
1
32
21
10
80
68
57
46
35
24
13
2
33
22
11
91
81
69
58
47
36
25
14
3
64
53
42
92
82
70
59
48
37
26
15
4
65
54
43
93
83
71
60
49
38
27
16
5
66
55
44
99
89
77
100
90
78
94
84
72
61
50
39
28
17
6
97
87
75
95
85
73
62
51
40
29
18
7
98
88
76
96
86
74
63
52
41
30
19
8
CONV
RP
SEND
%RCPT
L1 L2 L3
SBTL
CA/AT
PBAL
SRVC
CH1
CH2
CH3FINAL
NCRFND
CHK
AUTO
1
AUTO
2
SERV
#
AUTO
3
MDSE
SBTL
000
000
123
456
789
CL
RECEIPT
JOURNAL
@
FOR
PLU/ SUB
INQVOID

ER-A530 standard keyboard layout

2
Note
BS
Bill separation key
BIRTH
Birthday entry key
BT
Bill totalize/Bill transfer key (CHECK-ADD)
WASTE
Condiment next key
000
Numeric key
RFND
SALES
C
NEXT
Condiment cancel key
C
CANCEL
Edit tip key
EDIT
TIP
Table# recall key
GLU
RECALL
Refund sales key
Waste mode key
No delete key
NO DEL
14
The following function keys can optionally be added in place of those shown in the figure of the
standard keyboard layout. For details, please consult your authorized SHARP dealer.
Optional keys
%2 %5
Percent 2 thru 5 keys
Eat in 1 thru 3 keys
CONV2 CONV4
RA1
Received-on-account 1 and 2 keys
PO1
RA2
PO2
Paid-out 1 and 2 keys
AUTO
4
Transfer out key
TRANS
OUT
Transfer in key
TRANS
IN
Cash tip key
CA TIP
AUTO
10
Automatic sequencing 4 thru 10 keys
Cash 2 thru 5 keys
Currency conversion 2 thru 4 keys
CA2 CA5
CH4 CH9
Charge 4 thru 9 keys
-
2
-
Discount 2 thru 5 keys
5
DEPT
#
Dept. number key
SCALE
Scale entry key
Gasoline sales subtotal key
TIP
PAID
Tip paid key
DEPO
Deposit key
DEPO
RFND
Deposit refund key
CHK2 CHK5
Check 2 through 5 keys
EAT IN1EAT IN
3
Tax 1 thru 4 shift keys
TAX1
SHIFT
TAX4
SHIFT
GAS
SBTL
TAX
Manual tax key
NS
No-sale key
Tray subtotal key
TRAY
SBTL
RETURN
Return key
#/TM
Non-add code/Date & time display key
Charge tip key
CH TIP
Note
CHK
Automatic sequencing 1 thru 3 keys
Currency conversion key
Charge 1 thru 3 keys
CONV
Check 1 key
CA/AT
SBTL
Cash/amount tendered key
Server code entry key
PLU/UPC inquiry key
INQ
Discount 1 key
%
Percent 1 key
SERV
#
Previous balance key
PBAL
Service key
SRVC
Final key
FINAL
AUTO1AUTO
3
CH
1
CH
3
Merchandise subtotal key
MDSE
SBTL
Subtotal key
RP
SEND
Remote printer send key
NC
L1 L3
New check key
PLU level shift 1 thru 3 keys
15
Department and direct PLU keys can be expanded. If you require expansion of the department or
direct PLU keys, please contact your authorized SHARP dealer.
Note
Condiment next key
C
NEXT
Condiment cancel key
C
CANCEL
Edit tip key
EDIT
TIP
Table# recall key
GLU
RECALL
Food stamp shift key
FS
SHIFT
Food stamp tender key
FS
TEND
BIRTH
Birthday entry key
WASTE
RFND
SALES
Refund sales key
Waste mode key
UPC price change key
PRICE CHANGE
PRINT
Validation print key
GRT
EXEMPT
Gratuity exempt key
Price shift number key
P-SHIFT
#
Cover count entry key
CV
CNT
P1
Price level shift 1 thru 6 keys
P6
LEVEL
#
PLU level shift number key
L4
PLU level shift 4 and 5 keys
L5
BS
Bill separation key
BT
Bill totalize/Bill transfer key (CHECK-ADD)
Slip printer key
SLIP
No delete key
NO DEL
REPEAT
Repeat entry key
AMT
Amount entry key
OPEN TARE
Tare entry key
These key numbers are used for positioning of department keys and direct PLU keys. For further details with positioning departments and PLU keys, please refer to pages 109 and 130. This layout can be changed by your dealer.
001
006
011
016
002
007
012
017
003
008
013
018
004
009
014
019
005
010
015
020

Standard key number layout

3
For ER-A520
16
Insert the keyboard sheet between the keyboard cover and the cabinet as illustrated below. Then press the claws at the top of the keyboard cover into the slots in the cabinet.
Do not spread the keyboard cover too far to avoid tearing the tabs.
Replace the keyboard sheet with a new one if by chance it gets wet. Use of a wet keyboard
sheet may cause problems.
Be sure to use only SHARP-supplied keyboard sheets. Thick or hard sheets can make key operations difficult.
Place the keyboard sheet evenly under the keyboard cover.
If you require a new keyboard sheet, please contact your dealer.
The keyboard cover will eventually wear out. If your keyboard cover is dirty or broken, replace the
cover with a new one. For details, please contact your authorized SHARP dealer.
Note
Keyboard sheet
Cabinet
Keyboard cover

Installing the keyboard sheet (ER-A530)

4
028
029
030
031
021
022
023
024
025
026
027
039
040
041
042
032
033
034
035
036
037
038
050
051
052
053
043
044
045
046
047
048
049
061
062
063
064
054
055
056
057
058
059
060
072
073
074
075
065
066
067
068
069
070
071
083
084
085
086
076
077
087
088
099
100
078
079
080
081
082
096
097
098
089
090
091
092
093
094
095
108
109
110
101
102
103
104
105
106
107
118
119
120
111
112
113
114
115
116
117
For ER-A530
17

KEYS AND SWITCHES

The mode switch can be operated by inserting one of the three supplied mode keys – manager (MA), submanager (SM), and operator (OP) keys. These keys can be inserted or removed only when the switch is in the “REG” or “OFF” position.
The mode switch has these settings:
OFF: This mode locks all register operation.
No change occurs to register data.
OP X/Z: This setting allows cashiers to take X or Z reports for their sales
information. It can also be used for displaying the date/time and printing the employee’s arrival/departure times. And it can be used to toggle receipt state “ON” and “OFF” by pressing the
q
key. (This setting may be used only when your register has been
programmed for “OP X/Z mode available” in the PGM2 mode.)
REG: For entering sales PGM1: To program those items that need to be changed often: e.g., unit prices of departments, PLUs or
UPCs, and percentages.
PGM2: To program all PGM1 programs and those items that do not require frequent changes: e.g., date,
time, or a variety of register functions.
MGR: For manager’s and submanager’s entries
The manager can use this mode to make entries that are not permitted to be made by cashiers – for example, after-transaction voiding and override entries.
X1/Z1: To take the X/Z report for various daily totals. X2/Z2: To take the X/Z report for various periodic (weekly or monthly) consolidation of totals.
This key locks and unlocks the drawer. To lock it, turn 90 degrees counterclockwise. To unlock it, turn 90 degrees clockwise.
SK1-1

Drawer lock key

2
Operative range

Mode switch and mode keys

1
MA
SM OP
• Manager key (MA)
• Submanager key (SM)
• Operator key (OP)
18
This key locks and unlocks the printer cover. To lock it, turn 90 degrees counterclockwise. To unlock, turn 90 degrees clockwise.
The ER-A520 provides a cashier system and the ER-A530 provides a server system. The cashier/server codes are available in two variants: Variant 1, the codes are displayed (“0000” to “9999”), and Variant 2, the codes are not displayed (always “ ”). When the cashier/server code is assigned by Variant 2 (codes not displayed), the register prints as the cashier/server code and the cashier/server name are printed both on the receipt and journal for every transaction.
All settings depend on how the register has been programmed. For the available selection of these settings, please consult your authorized SHARP dealer.
You can disable receipt printing in the REG mode to save paper using the receipt function. To disable receipt printing, press the
q
key in the OP X/Z position. This key toggles the receipt printing status ON and OFF. To
check the receipt printing status, turn the mode switch to the OP X/Z position or press the
c
key in the REG
mode. When the function is in the OFF status, the receipt off indicator “_” illuminates.
Your register will print reports regardless of the receipt status. This means that the receipt roll must be installed even when the receipt state is
OFF” when taking reports.
Note

Receipt ON/OFF function

5
Note
‹‹
Cashier/server
code
To display the current cashier/server code
Sign-on
Variant 1 : (Code is displayed.)
Variant 2 : (Code is not displayed.)
Sign-off Variant 1 / Variant 2 :
SERV
/
Cashier/server
code
‹‹
SERV
/
‹‹
SERV
/
‹‹
SERV
/
‹‹
SERV
/
Procedure

Cashier/Server code entry key

4

Printer cover lock key

3
19

DISPLAYS

The operator display consists of a two-line dot-matrix display (16 characters/line).
• Cashier/server code or mode name
The mode you are in is displayed. When a cashier/server is assigned, the cashier/server code is displayed in the REG or OP X/Z mode. For example, “0001” is displayed when cashier/server 0001 is assigned.
• Repeat
The number of repeats is displayed, starting at “2” and increments with each repeat. When you have
registered an item ten times, the display will show “0”. (2 3 ......9 0 1 2...)
• Sentinel mark
When amounts in the drawer reaches the amount you preprogrammed, the sentinel mark “X” is displayed to advice you to remove the money to a safe place.
• Power save mark
When the cash register goes into the power save mode, the power save mark (decimal point) is displayed.
• Stock alarm indicator
When the stock counter of the PLU or UPC which you entered is zero or negative, the alarm indicator (decimal point) is displayed.
• Function message display area
Item labels of departments and PLU/subdepartments/UPC and function text you use, such as %1, (–) and CASH are displayed here. For the details of function texts, please refer to pages 146 to 149. When an amount is to be entered or entered, “AMOUNT” is displayed: When an amount is to be entered, – – – – – – – is displayed in the numeric entry display area with “AMOUNT”. When a preset price has been set, the price is displayed in the numeric entry display area with “AMOUNT”.
• Numeric entry display area
Numbers entered using numeric keys are displayed here.
Date and time display
Date and time appear on the display in the OP X/Z, REG, or MGR mode. In the REG or MGR mode, press the key to display the date and time.
Error messages
When an error occurs, the corresponding error message is displayed in the function message display area. For the details of error messages, please refer to the “Error message table” on page 223.

Customer display (Pop-up type)

2
#/
TM
Function message display area
Cashier/server code or mode name
Numeric entry display area
Receipt OFF indicator (“_”)
/
Stock alarm indicator (“•”)
Repeat / Sentinel mark / Power save mark
Dept. name / PLU or UPC name / function text
Price level / PLU level (e.g. P2L3)

Operator display

1
20

PRIOR TO ENTRIES

Before registrations, insert the operator key into the mode switch and turn it to the REG position and check the following items:

Receipt and journal paper rolls

If the receipt and journal paper rolls are not set in the machine or there are low rolls, install new ones according to section “4. Installing and removing the paper rolls” under “OPERATOR MAINTENANCE.”

Receipt ON/OFF function

You can disable receipt printing in the REG mode to save paper using the receipt function. To disable receipt printing, press the
q
key in the OP X/Z position. This key toggles the receipt printing status ON and OFF.
To check the receipt printing status, turn the mode switch to the OP X/Z position or press the
c
key in the REG
mode. When the function is in the OFF status, the receipt off indicator “_” illuminates.
Your register will print reports regardless of the receipt state. This means that the receipt roll must be installed even when the receipt state is “OFF” when taking reports.

Cashier/Server assignment

The ER-A520 requires a cashier to be assigned prior to operational item entries. The ER-A530 enforces that a server must enter their code into the register. Depending on register settings, it is possible to keep the same cashier/server code assigned when the same cashier/server is to be used for all transactions within a set period. As previously mentioned, there are two variants to consider for the display and print of the cashier/server codes.
The operation entries depend on how the register has been programmed. To determine which selections should be considered, please consult your local dealer.
Note

Preparations for entries

1
FOR THE OPERATOR
Note
Logo message or graphic logo (varies depending on programming.)
Cashier/Server code
(“ ” is printed in Variant 2.)
Cashier/Server name
21
• If you want to enter a cashier/server code before every transaction, please consult your authorized SHARP dealer.
• For the display type selection of the cashier/server code, “Variant 1” has been preset. For the selection of the “Variant 2”, consult your authorized SHARP dealer.
• The cashier/server can be changed during a transaction. Please consult your authorized SHARP dealer.
The register will enter into the power save mode when no entries are performed based on the pre-programmed time limit (by default, 30 minutes). When the register goes to the power save mode, the operator and customer displays will turn off. This is indicated by a decimal point at the left most position of the lower line. The register will return to normal operation mode when any key is pressed or a mode is changed with the mode key. Please note when the register is recovered by any key entry the initial key entry is ignored. After the recovery, you may start the key entries from the beginning.
In the following examples, your register will go into an error state accompanied with a warning beep and a corresponding error message. Clear the error state by pressing the
c
key and take proper action.
Please refer to the error message table on page 223.
• When you enter an over 32-digit number (entry limit overflow): Cancel the entry and re-enter a valid number.
• When you make an error in key operation: Clear the error and continue entries.
• When you make an entry beyond a programmed amount entry limit: Check to see if the entered amount is correct. If it is correct, it be possible to make the entry in the MGR mode. Contact your manager.
• When an including-tax subtotal exceeds eight digits: Clear the subtotal by pressing the
c
key and press the
a, Å
thru É, k, thru , or hthru key to finalize the transaction.
CH9
CHK5
CHK2

Error warning

3

Power save mode

2
Note
‹‹
Cashier/server
code
To display the current cashier/server code
Sign-on
Variant 1 : (Code is displayed.)
Variant 2 : (Code is not displayed.)
Sign-off Variant 1 / Variant 2 :
SERV
/
Cashier/server
code
‹‹
SERV
/
‹‹
SERV
/
‹‹
SERV
/
‹‹
SERV
/
Procedure
22

ENTRIES

The example entries provided within this manual describe the function key labeled which is used for the model ER-A520. For the model ER-A530, please substitute the key with the
P
function key.

Single item entries

Department entries (direct department entries)
Enter a unit price and press a department key. If you use a programmed unit price, press a department key only.
*Less than the programmed upper limit amounts
When those departments for which the unit price has been programmed as zero (0) are entered, only the sales quantity is added.
Department entries (indirect department entries)
*Less than the programmed upper limit
amounts
PLU entries (indirect PLU entries)
Enter a PLU code and press the key.
When those PLU’s for which the unit price has been programmed as zero (0) are entered, only the sales quantity is added.
Subdepartment (open PLU, open and preset PLU) entries
*Less than the programmed upper limit
amounts
PLU entries (direct PLU entries)
Direct PLU key
Unit price *
(for subdept.)
When using a programmed unit price
PLU code
Unit price *
(max. 7 digits)
When using a programmed unit price
or
å
PLU/ UPC
PLU/
UPC
Note
PLU code
PLU/ UPC
PLU/ UPC
à
Unit price *
(max. 7 digits)
When using a programmed unit price
Dept. code
(1–99)
à
When [preset only dept.] is entered.
or
å
Note
Department keyUnit price *
(max. 7 digits)
When using a programmed unit price
Procedure

Item entries

1
PLU/ UPC
PLU/ UPC
Note
23

Repeat entries

You can use this function for entering a sale of two or more same items. You can use the
è
key to repeat entry instead of department, å, direct PLU or key.
200
8 8 8
5 à680
à à
10
P P P
ó ó
60
P
500
P P
5012345678900
P P
600
2 è è a
PrintKey operation
Example
PLU/ UPC
1200
3 5
8
à
5 à680
à
2
P
11 P1200
P
ô
5012345678900
P
a
PrintKey operation
Example
Repeated department entry (direct)
Repeated department entry (indirect)
Repeated PLU entry (indirect)
Repeated PLU entry (direct)
Repeated subdepartment entry
Repeated UPC entry
Repeated department entry (direct) using the repeat key
Ä
Scan UPC code
UPC code
(max.13 digits)
å
Unit price
(max. 6 digits)
To set “auto-delete”
PLU/
UPC
(Registration)
NON
DELETE
To cancel the learing function entry
DEPT
#
Dept. no.
(1 - 99)
(
1
~ )
When the dept. key is depressed directly
c
99
UPC entries
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/
UPC
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/ UPC
24

Multiplication entries

Use this feature when you need to enter two or more same items. This feature helps when you sell a large quantity of items or need to enter quantities that contain decimals.
• After scanning a UPC code or pressing the key, when the item does not exist in the file, the display will show “NO RECORD”. Enter the unit price using the
å
key and department no. with the àkey.
• Q’ty: Up to four digits integer + three digits decimal
• Unit price: Less than a programmed upper limit
• Q’ty × unit price: Up to seven digits
You must use a decimal point (.) key when entering quantities that are fractional.
Note
7 .500
@
165
8
2
@
5
à
250
à
15
@
13
P
8 .250
@ ò
3
@
60
P
100
P
5
@
5012345678900
P
a
PrintKey operation
Example
@
Unit price
PLU code
à
Unit price Direct PLU key
Q’ty Department key
When using a programmed unit price
Dept. entry (direct)
Dept. code Dept. entry (indirect)
PLU entry (indirect)
PLU/subdept. entry (indirect)
PLU/subdept. entry (direct)
Unit price
When [preset only dept.] is entered.
PLU code
Unit price
or
å
PLU/ UPC
à
or
å
PLU/ UPC
PLU/ UPC
Ä
Scan UPC code
UPC code
UPC entry
PLU/ UPC
Procedure
Department entry (direct)
Department entry (indirect)
PLU entry (indirect)
PLU entry (direct)
Subdepartment entry
UPC entry
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/ UPC
25

Successive multiplication entries

This function may be desired when you enter a sale of items sold by area (square feet).
• After scanning a UPC code or pressing the key, when the item does not exist in the file, the display will show “NO RECORD”. Enter the unit price using the
å
key and department no. with the àkey.
• Length or width: Up to seven digits (4-digit integer + 3-digit decimal)
• Unit price: Less than a programmed upper limit
• Length × Width × Unit price: Up to seven digits
For actual use of this function, please consult your dealer.
You must use a decimal point (
.
) key when entering quantities that are fractional.
3
@
4
@
400
5
1 .500
@
2 .500
@
8
P
1 .750
@
1 .750
@
6
P
600
P
4
@
5
@
5099887654302
P
a
PrintKey operation
Example
Note
Procedure
Department entry
PLU entry
Subdepartment entry
UPC entry
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/ UPC
When using a programmed unit price
Length Unit price
@@
Dept. entry (direct)Width Department key
Dept. code Dept. entry (indirect)
PLU code
PLU code
Unit price Direct PLU key
à
PLU/ UPC
PLU/ UPC
Ä
UPC code
PLU/ UPC
Unit price
When [preset only dept.] is entered.
Unit price
Scan UPC code
à
PLU/ UPC
or
or
å
å
PLU entry (indirect)
PLU/subdept. entry (indirect)
PLU/subdept. entry (direct)
UPC entry
26

Split-pricing entries

You may use this function when your customer wants to purchase items normally sold in bulk.
• After scanning a UPC code or pressing the key, when the item does not exist in the file, the display will show “NO RECORD”. Enter the unit price using the
å
key and department no. with the àkey.
• Selling quantity: Up to four digits integer + three digits decimal
• Base quantity: Up to two digits (integer)
You must use the decimal point (
.
) key when entering selling quantities that are fractional.
Note
7
@
10
@
600
7
8
@
5
@
35
P
5
@
6
@
5045678912304
P
a
PrintKey operation
Example
Procedure
Department entry
PLU entry
UPC entry
@
Unit price
per base q’ty
PLU code
Base q’ty
@
Selling q’ty
When using a programmed unit price
Only when you use a base q’ty programmed for PLU code
Department key
à
Dept. code
Unit price
When [preset only dept.] is entered.
PLU code
Direct PLU key
Unit price
per base q’ty
Unit price
per base q’ty
PLU code
PLU code
Unit price
per base q’ty
Direct PLU key
Unit price
per base q’ty
à
or
å
or
å
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/
UPC
PLU/
UPC
or
å
PLU/ UPC
Ä
UPC code
PLU/ UPC
Ä
UPC code
PLU/ UPC
PLU/
UPC
PLU/
UPC
PLU/ UPC
27

Single item cash sale (SICS)/single item finalize (SIF) entries

SICS entries
• This function is useful when a sale is for only one item and is for cash; such as a pack of cigarettes. This function is applicable only to those departments that have been set for SICS or to their associated PLUs, subdepartments or UPCs.
• The transaction is finalized and the drawer opens as soon as you press the department key,
å
key, key,
the direct PLU key or scanning a UPC code.
If an entry to a department, PLU/subdepartment or UPC set for SICS follows entries to departments, PLUs/subdepartments or UPC not set for SICS, it does not finalize and results in a normal sale.
SIF entries
• If an entry to a department, PLU/subdepartment or UPC set for SIF follows entries to departments, PLUs/subdepartments or UPC not set for SIF, the transaction is finalized immediately as a cash sale.
• Like the SICS function, this function is available for single-item cash settlement.
1745
8
1500
For finishing
9
the transaction
PrintKey operation
Example
Note
250
For finishing
9
the transaction
PrintKey operation
Example
PLU/ UPC
28

Scale entries

For making entries for weighed items, a scale may be connected where by the weight is automatically read from the scale. To make refund or return entries, the weight is entered manually while the scale platter is empty and reads zero.
i) Auto scale entries
• Open tare weight: Up to 5 digits (integer + decimal)
• Net weight: Up to 5 digits (integer + decimal)
• Base weight: Up to 2 digits (integer)
The register can be programmed with up to nine tare tables and allows different tares to be assigned to them.
When the
S
key is pressed, the weight is automatically read from the connected scale (option)
and the net weight appears in the register display.
When the item is programmed for “Scale compulsory”, it is not necessary to press the
S
key.
S
200
1
S
1
P
c
PrintKey operation
Example
Note
Procedure
When using a programmed unit price
`
Unit price
per base wt.
Dept. code
Unit price
per base wt.
Department
à
Department
Unit price
When [preset only dept.] is entered.
à
or
å
When you use a programmed tare no.
Tare number
(1-9)
SCALE
When base wt. is 1 LB (or 1 KG)
Base wt.
OPEN TARE
Open tare
weight
Only when you use a base wt. programmed for PLU code
Dept. code
PLU code
PLU code
Unit price
per base wt.
UPC code
PLU code
PLU code
Unit price
per base wt.
UPC code
à
PLU/ UPC
PLU/ UPC
Direct PLU key
Unit price
When [preset only dept.] is entered.
Unit price
per base wt.
Ä
PLU/
UPC
PLU/
UPC
PLU/
UPC
Direct PLU key
Unit price
per base wt.
Ä
PLU/ UPC
à
PLU/ UPC
PLU/ UPC
or
å
or
or
å
å
PLU/ UPC
29
ii) Manual scale entries of refunded items
• Net weight: Up to 5 digits (integer + decimal) which is from the customer’s receipt.
• Base weight: Up to 2 digits (integer)
32 .85
Ï S
200
1
37 .25
Ï S1 P
c
PrintKey operation
Example
Procedure
`
Base wt.
Net weight
Only when you use a base wt. programmed for PLU code
SCALE
When using a programmed unit price
When base wt. is 1 LB (or 1 KG)
Unit price
per base wt.
Ï
Department
à
Dept. code
Unit price
When [preset only dept.] is entered.
Department
Unit price
per base wt.
Unit price
per base wt.
à
Dept. code
Unit price
When [preset only dept.] is entered.
Direct PLU key
PLU code
PLU code
Unit price
per base wt.
Unit price
per base wt.
Direct PLU key
PLU code
PLU code
Unit price
per base wt.
à
or
å
à
or
å
or
å
PLU/ UPC
or
å
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/ UPC
Ä
UPC code
PLU/ UPC
Ä
UPC code
PLU/
UPC
Ï
RETERN
PLU/
UPC

PLU level shift (for direct PLU)

This shift function can allow access to PLUs on your register without adding additional direct PLU keys. You can use direct PLUs in five levels by utilizing PLU level shift keys
l
thru . The level shift key shifts the PLU level from the other four to the required level. (The normal level is level 1.) You can also shift PLU level by entering a level number and pressing the PLU level shift number key,
ä
.
You must program your machine in the PGM2 mode to select one of the two PLU level shift modes — automatic return mode* and lock shift mode** — and decide whether to allow PLU level shift in both the REG and MGR modes or in the MGR mode alone. * The automatic return mode automatically shifts the PLU level back to level 1 after a direct PLU key is pressed.
You can select whether the PLU level should return each time you enter one item or each time you finalize one transaction.
** The lock shift mode holds the current PLU level until a PLU level shift key is pressed.
Automatic return mode (for PLU levels)
If you shift the PLU level while in the automatic return mode, press the desired PLU level shift key before numeric entries.
• each item
• each transaction
Lock shift mode (for PLU levels)
If you shift the PLU level while in the lock shift mode, press the desired PLU level shift key before numeric entries.
If you select the automatic return mode, it is not necessary to use the
l
key on the keyboard, but
if you select the lock shift mode, it is necessary to use the key.
Note
l
ä
Direct PLU
(Q’ty,
@
)
Numeric entry
Level no.
(1 to 5)
(Staying in the current level)
L5
thru
To shift the level of another PLU
Procedure
Payment
¬
ä
Direct PLU
(Q’ty,
@
)
Numeric entry
Level no.
(1 to 5)
L5
thru
(Returning to level 1)
¬
ä
Direct PLU
(Q’ty,
@
)
Numeric entry
Level no.
(1 to 5)
(Returning to level 1)
L5
thru
Procedure
L5
30
Direct PLU1: PLU code 1 (PLU level 1), PLU code 65 (PLU level 2) Direct PLU2: PLU code 2 (PLU level 1), PLU code 66 (PLU level 2)
• When your machine has been programmed for the automatic return mode:
• When your machine has been programmed for the lock shift mode:
l
1
¬
1 2 1
a
PrintKey operation
1
¬
1 2 1
a
PrintKey operation
Example
31

PLU/UPC price level shift

Six different price level shifts can be programmed for each PLU or UPC. The price levels can be changed for PLU or UPC registrations. You can change a PLU/UPC price among six prices by utilizing the price level shift keys thru , the level shift key shifts the price level from the other five to the required level. (The normal level is level 1.) You can also a shift price level by entering level number and pressing the price level shift number key,
¥
.
You must program the price level shift mode (i.e. automatic return mode* or lock shift mode**) and the operating mode to be used for the price level shift (i.e. both REG/MGR modes or MGR mode alone). * The automatic return mode automatically shifts the PLU/UPC price level back to level 1 after a PLU/UPC shift
entry. You can select whether the price level should return each time you enter one item or each time you finalize one transaction.
** The lock shift mode holds the current PLU/UPC price level until pressing the price level shift key.
Automatic return mode (for price levels)
If your register has been programmed for the price level shift in the automatic return mode, press a desired price level shift key before a numeric type entry.
(each item)
(each transaction)
Lock shift mode (for price levels)
If your register has been programmed for the price level shift in the lock shift mode, press a desired price level shift key before a numeric type entry.
If you select the automatic return mode, it is not necessary to use the key on the keyboard, but if you select the lock shift mode, it is necessary to use the key.
You can program “printing of the price level text. Please refer to “Programming for optional feature
selection” described in the “PROGRAMMING” section of this manual.
P1
Note
PLU/UPC code
(Q ty,
@
etc.)
Numeric entry
Direct PLU
To shift the price level of another PLU/UPC
PLU/ UPC
Ä
Level no.
(1 to 6)
thru
P1
P6
¥
Procedure
Payment
PLU/UPC code
(Q ty,
@
etc.)
Numeric entry
Direct PLU
PLU/
UPC
Ä
(Returning to price level 1)
Level no.
(1 to 6)
thru
P2
P6
¥
PLU/UPC code
(Q ty,
@
etc.)
Numeric entry
Direct PLU
PLU/ UPC
Ä
(Returning to price level 1)
Level no.
(1 to 6)
thru
P2
P6
¥
Procedure
P6
P1
32
PLU price level 1: PLU 1 ($1.91), PLU 2 ($0.79) PLU price level 2: PLU 1 ($2.00), PLU 2 ($0.99)
When your register has been programmed for the automatic return mode (by one item):
When your register has been programmed for the lock shift mode:

Set PLU entries

Operations are the same as normal PLU’s. When a set PLU is entered, an entered or preset amount is printed as the unit price and then those PLUs linked to the set PLU are printed automatically.
The unit price of the set PLU (ex. PLU 20) is the registered amount of the set PLU. The tied PLU’s memory is updated only by the entered quantity.
Note
p
a
PrintKey operation
Example
1
P
1
P
2
P
a
PrintKey operation
1
P
1
P
2
P
a
PrintKey operation
Example
P2
33
P2
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/ UPC

Link PLU/UPC entries

The operation is the same as normal PLU’s/UPC’s. When this PLU/UPC is entered, the linked PLU’s amount is included and the linked PLU’s label is printed automatically. Only the 1st PLU is affected by the status shift keys (,
|, «, »
or ˛key). The percent calculation is in effect for the amount of the 1st ranking PLU.
When PLU 21 is linking PLU 25,26,27 as follows

Age verification (Birthday entry)

The age verification function is used for prohibiting the sale of goods (departments, PLUs or UPCs) for certain aged persons based on a registered birthday. When a department/PLU/UPC for which a figure other than zero (01 to 99) has been programmed as the age limitation is entered, a birthday entry must be completed.
A birthday entry can be performed two or more times at any point during a transaction, however the last entered birthday remains in effect.
You can enter the date as far back as 98 years.
[Ex.] When the current year is 2005 : you can enter the year 1907-2005.
Oct. 2, 1985 (When dept. 7 is programmed as the age limitation “17”.)
When birthday printing is allowed, through programming (Job no. 2616), the birthday date is printed.
PrintKey operation
Example
Note
XXXXXX
Birthday (five or six digits)
BIRTH
Procedure
21
P
a
PrintKey operation
Example
TAX
SHIFT
34
PLU/ UPC
100285
BIRTH
300
7
7 a

Mix-and-match entries

This function is convenient for matching several PLU/UPC items and selling them in a lump (e.g. bundle sale, multi-packed sale, etc.). The matching q’ty and adjusted amount are assigned to a mix-and-match table. All items that are programmed into the same table are treated as if they belong to one group.
Selling on a mix-and-match basis the following items in table no. 1 to which the matching q’ty “3” and the adjusted amount “$10.00” are assigned:
PLU 40 (Unit price: $5.00)
PLU 41 (Unit price: $3.00)
PLU 42 (Unit price: $2.50)

Condiment entries (for PLUs)

Your register may be programmed for prompting condiment and preparatory instructions for a menu-item PLU.
Example:
When you enter a menu-item PLU, a prompting message such as “HOWCOOK?” will appear. You must specify a PLU such as “RARE” to meet a special order of the guest. In an example of the condiment table show below, it is assumed the condiment table #1 and #4 is assigned to PLU 210 (item label: STEAK/unit price: $13:00). When you enter PLU 210, the message “HOWCOOK?” will appear. You are allowed to enter one of the PLU code, 221, 222 and 223. When you enter PLU 221, “RARE” is registered and the next message “POTATO?” will appear. When you enter PLU 226, “P.CHIPS” is registered. Then press the
a
key to end this entry.
210
P
221
P
226
P
c
PrintKey operation
Example
220 221 222 223
(HOWCOOK?) (RARE 0.00) (MED.RARE 0.00) (WELLDONE 0.00)
225 226 227 228
(POTATO?) (P. CHIPS 0.60) (MASHED.P 0.60) (BAKED.P 0.50)
Table number PLU codes for condiment entry (programmed text, price) Next table no.
1
4
4
Condiment PLUs (preset price entry is allowed.)Message text
Menu-item PLUs (PLU210 is linked to table #1)
Treated as $5.00 item
/
Treated as $3.00 item
!
Treated as $2.00 item
@
a
PrintKey operation
Example
35
“HOWCOOK?” appears.
“POTATO?” appears.
PLU/ UPC
PLU/ UPC
PLU/ UPC
36

Price inquiry (view) function (for PLU/UPCs)

You can use this function when you want to know the unit price of the PLU/UPC item during sales transactions while in the REG/MGR mode.
*1: Press the
c
key to cancel the inquiring (view) mode.
*2: Press the
å
key when you want to register the unit price of the PLU/UPC displayed.
*3: You can change the unit price temporarily in the MGR mode. The unit price which is programmed in PGM
mode is not changed (Price override entry).
For the repeat entry, use the
è
key.
5
P
Ù
5089123456708
P
å
c
PrintKey operation
Example
Note
Procedure
Your register will continue to prompt for the condiment entry until you finish the entire condiment entry programmed for the PLU. During the condiment entry, if you enter a normal PLU, which is not in the condiment table, an error message will appear in case the condiment entry is compulsory.
When the key is pressed, the entry skips to the next table which is programmed.
When the key is pressed, its condiment entry is canceled in the programmed mode
(REG/MGR or MGR).
When you enter a PLU priced at “0.00,” only the text will be printed on the receipt.
No refund entry is possible for any condiment entries. When you perform a refund entry with a
menu-item PLU and the condiment PLUs assigned to the menu-item PLU are automatically registered as a refund entry.
You may omit the compulsory condiment entry by pressing the key.
C
NEXTCCANCELCNEXT
Note
Price is displayed.
PLU/ UPC
PLU/ UPC
"VIEW" is displayed.
Numeric entry
Ù
(Q'ty )
`
Scan UPC code
Ä
UPC code
PLU code Unit price
PLU/
UPC
PLU/ UPC
PLU/
or
UPC
å
Direct PLUUnit price
The total sales amount of the PLU/UPC is displayed.
1
*
c
2
*
å
3
*
Unit price(MGR mode)
å

UPC learning function

When you enter or scan an undefined code, you are required to enter the unit price “amount” and the associated department. The UPC code, unit price and the department entered are stored in the dynamic UPC file (if opened, and if not opened, in the PLU/UPC file) and is used for future sales entries.
• When there is no capacity remaining in the file, the data is not stored in the file.
• The text of the entered department is applied to the entered UPC code.
• You can use the UPC learning function in the training mode. This may be convenient to practice when installing the scanning system.
* Press the
Ì
key when you want to exempt the UPC code entered from the non-accessed UPC delete
function (deletion occurs by executing #105 in Z1 mode).
For the repeat entry, use the
è
key.
5056789123404
Û
750
5
c
PrintKey operation
Example
Note
Procedure
Note
“NO RECORD”, “PRICE ->
DEPT” are displayed.
PLU/ UPC
37
"NO RECORD" is displayed and the beep sound occurs three times. Then, "PRICE -> DEPT" is displayed to guide you to enter unit price and associated department code.
Scan an undefined UPC code
Ä
Undifined
UPC code
PLU/ UPC
When the unit price is zero, or in case of non-PLU type UPC code having price info. or press code.
Unit price
c
To cancel the operation
*
Ì
Department key
å
Dept. no.
"ENTER DEPT#" is displayed
à

Price change function (for PLU/UPCs)

You can use this function when you need to change the unit price or associated department of a PLU/UPC item in REG/MGR mode. There are two methods for price changes:
1. Price change mode You can change the preset price and/or the associated department of a PLU/UPC item without entering PGM mode.
2. Changing a price during a transaction When a wrong PLU/UPC price and/or associated department is found during transaction, you can correct them at the time of the transaction. With the entry of a new price and/or associated department, the preset price and/or associated department is automatically changed to the new price and/or associated department.
For the Non-PLU type price embedded UPC-A codes, the prices in the codes have the priority over the preset prices. So, for these codes, a changed price is valid only when the price change is executed.
Price change mode
Ê
UPC code
Ä
Scan UPC code
"PRICE CHANGE" is displayed.
Ê
Dept no.
Department key
To cancel
To enter 0
åà
c
Unit price
To change the unit price only
To change the associated dept. using the dept. no. entry key
To change the associated dept. directly by depressing the corresponding key
Ê
Changing a price during a transaction
PLU/ UPC
PLU code
PLU/ UPC
Direct PLU
"PRICE & DEPT" is displayed.
"ENTER DEPT#" is displayed.
UPC code
or
Ä
Scan UPC code
å
PLU/ UPC
PLU code Unit price
PLU/ UPC
PLU/ UPC
Direct PLUUnit price
Procedure
Note
38
39
• Price change mode
• Changing a price during a transaction
• When an undefined code is entered in the price change mode, the register results in an error.
• When you press the
Ê
key during a transaction, the UPC entry is voided upon the 1st
depression of the
Ê
key, then you are allowed to enter a correct price and/or associated
department.
• In case the item label of the UPC is the same as the associated department, the item label is changed to the item label of the new associated department when the associated department is changed.
• For the repeat entry, use the
è
key.
Note
5087654321106
Û
Ê
600
Ê
c
PrintKey operation
Ê
5087654321106
Û
600
Ê
PrintKey operation
Example
Associated dept. no.
The journal printer prints the following format in this position.
PLU/ UPC
PLU/ UPC
Your register provides these five types of subtotals:

Merchandise subtotal

Press the Âkey at any point during a transaction. The net sale subtotal - not including tax - will appear in the
display.

Taxable subtotal

Taxable 1 subtotal
Press the (
'
) and ıkeys in this order at any point during a transaction. The sale subtotal of
taxable 1 items will appear in the display.
Taxable 2 subtotal
Press the
|
and ıkeys in this order at any point during a transaction. The sale subtotal of taxable 2
items will appear in the display.
Taxable 3 subtotal
Press the
«
and ıkeys in this order at any point during a transaction. The sale subtotal of taxable 3
items will appear in the display.
Taxable 4 subtotal
Press the
»
and ıkeys in this order at any point during a transaction. The sale subtotal of taxable 4
items will appear in the display.

Including-tax subtotal (full subtotal)

Press the ıkey at any point during a transaction. The sale subtotal including tax will appear in the display.

Food stamp-eligible subtotal

Press the fkey at any point during a transaction. The sale subtotal of items eligible for food stamp payment will appear in the display.

Tray subtotal

Press the ykey during a transaction in the REG or MGR mode. The contents of the tray total itemizer which include tax are printed and displayed.

Eat-in subtotal

You may press an eat-in key prior to entering a payment. Your register will calculate a subtotal according to the programmed tax exemption status and display the subtotal, the symbol “EAT IN,” and a corresponding caption (“EAT IN 1,” “EAT IN 2,” or “EAT IN 3”). For the transaction with the eat-in subtotal, you must finalize the transaction by making a payment entry. Just after pressing the eat-in key, however, you can cancel the entry of that key by pressing the
c
key or
another eat-in function key.

Gasoline discount subtotal

Use the following procedure to get a gasoline discount subtotal; amount after gas discount amount is deducted. The gasoline discount subtotal will appear in the display.
a
: 1 k : 6 ( : 11 , : 16
Å
: 2 k : 7 ) : 12 , : 17
Å
: 3 k : 8 * : 13 , : 18
Å
: 4 k : 9 + : 14 , : 19
É
: 5 k : 10 , : 15
6 7 8 9
3 4
CHK2
CHK3
CHK4
CHK5
*:

Displaying and printing subtotals

2
40
TAX
SHIFT
Number of media to be used for finalization*
(1-19)
GAS
SBTL
41

Cash or Check tendering

Press the ıkey to get an including-tax subtotal, enter the amount tendered by your customer, then press the
a
or one of the Åthru Ékeys if it is a cash tender or press the kor
one of the thru
key if it is a check tender. When the amount tendered is greater than the amount of the sale, your register will show the change due amount and the text “CHANGE”. Otherwise your register will show the text “DUE” and a deficit. Make a correct tender entry.
Your customer pays $10.00 for an including-tax subtotal of $7.35.
Cash tendering
Check tendering

Mixed tendering (check + cash)

Your customer pays $10.00 by check and $5.00 in cash for an including-tax subtotal of $14.56.
ı
1000
k
500
a
PrintKey operation
Example
PrintKey operation
ı
1000
a
PrintKey operation
Example
CHK5
CHK2

Finalization of transaction

3
ı
1000
k

Cash or Check sale that does not need any tender entry

Enter items and press the aor one of the Åthru Ékeys if it is a cash sale or press the kor
one of the
thru keys if it is a check sale. Your register will display the total sale amount.
Selling a $3.00 item (dept. 6) and another $7.15 item (PLU 10) for cash

Charge (credit) sale

Enter items and press the corresponding charge keys (hthru ).
Selling a $25.00 item (dept. 5) and a $32.50 item (dept. 6) and accepting the payment by charge 1 account
Amount tendering operations (i.e., change calculations) can be achieved by the
h
thru key when it has
been preset in PGM2 job #2320.

Mixed-tender sale (cash or check tendering + charge tendering)

Your customer pays $9.50 in cash and $40.00 by charge 1 for an including-tax subtotal of $49.50.
ı
950
a
h
PrintKey operation
Example
2500
5
3250
6
h
PrintKey operation
Example
CH9
300
6
10
P
a
PrintKey operation
Example
CHK5
CHK2
42
PLU/ UPC
In the case of check 1 sale
CH9
43

Food stamp tendering

If your customer makes payment (or tendering) in food stamps, obtain the food stamp-eligible subtotal* by pressing the
f
key and make a food stamp tender entry before entering a cash or check tender.
The food stamp-eligible subtotal* depends upon how your register is programmed based on the food stamp-eligibility of the automatic tax on a sale of items eligible for food stamp payment, or whether your register is programmed to allow the automatic tax to be paid with food stamps or not or to exempt taxation. The example below presupposes that your register has been programmed to exempt taxation.
When the amount tendered in food stamps is greater than the food stamp-eligible subtotal:
Your register shows two change due amounts in its display. The food stamp change due appears at the left of the display in dollars and the cash change at the right in cents.
• When you enter only items eligible for food stamp payment.
Your customer purchases a $4.25 item (dept.4, taxable 1, eligible for food stamp payment) and another $4.00 item (PLU 34, taxable 2, eligible for food stamp payment) and tenders $10.00 food stamps for them.
• Mixed sale of an item eligible for food stamps and another item not eligible for food stamps
Your customer purchases a $2.48 item (dept. 5, taxable 1, eligible for food stamps) and another $5.42 item (dept. 8, nontaxable, ineligible for food stamps) and pays $5.00 in food stamps and $5.00 in cash.
Display shows:
Food stamp change
Cash
change
Food stamp change due
Cash change due
248
5
542
8 f
500
f
500
a
PrintKey operation
Example
Display shows:
Food stamp change
Cash
change
Food stamp change due
Cash change due
425
4
34
P
f
1000
f
To display the food stamp-eligible subtotal
UPC
PrintKey operation
Example
Note

Food stamp calculations

4
44
When the food stamp tender is smaller than the food stamp-eligible subtotal:
• Accept the remainder in food stamps or in cash or check. If your register is programmed to exempt taxation, additional food stamp tender is not allowed.
Your customer buys a $3.18 item (dept. 5, taxable 1, eligible for food stamps) and another $1.24 item (dept.7, taxable 2, eligible for food stamps) and pays $4.00 in food stamps and the remainder - $1.00 in cash.

Food stamp status shift

Your machine allows you to shift the programmed food-stamp status of each department, PLU/UPC or -thru
±
, percent key by pressing the ˛key prior to those keys. After each entry is completed, the programmed
food stamp status is resumed.
You sell a $2.32 item of dept. 2 (food-stamp eligible) as a food-stamp ineligible item and another $3.18 item of PLU 86 (food-stamp ineligible) as a food-stamp eligible item and accept $4.00 in food stamps and $2.00 in cash.
232
˛2
86
˛ P
f
400
f
200
a
PrintKey operation
Example
PrintKey operation
Example
PLU/ UPC
318
5
124
7 f
400
To enter the cash tendering of the remainder
100
f a
45

Automatic tax

When your register is programmed with a tax table (or tax rate) and the tax status of an individual department and PLU/UPC is set for taxable, it computes the automatic tax on any item that is entered directly into the department or indirectly via a related PLU/UPC.
Selling five $6.70 items (dept. 1, taxable 1) and one $7.15 item (PLU 85, taxable 2) for cash

Manual tax

Your machine allows you to enter tax manually after item entries.
Selling an $8.00 item (dept. 7) for cash with 50 cents as tax
800
7
50
† a
PrintKey operation
Example
5
@
670
1
85
P
a
PrintKey operation
Example

Tax calculations

5
PLU/ UPC

Automatic-tax delete

You can delete the automatic tax on the taxable 1, taxable 2, taxable 3 and taxable 4 subtotal of each transaction by pressing the
key after the subtotal is displayed.
Selling a $7.25 item (dept. 1, taxable 1) and another $5.15 item (dept. 3, taxable 2) for cash and entering the sale as a non-taxable one
If any of the media keys (i.e. cash, check or charge 1 thru charge 5) are programmed as tax delete in PGM2 mode, the tax can be deleted without using the procedures above. In this case, depressing a corresponding media key alone will always cause the programmed tax to be deleted.
When the
Å
key is programmed as tax delete for the same case with the above example
725
1
515
3 Å
PrintKey operation
Example
725
1
515
3
*
\ ı
† a
PrintKey operation
Example
46
*
for ER-A530
TAX1
SHIFT
TAX
SHIFT
47

Tax status shift

Your machine allows you to shift the programmed tax status of each department, -thru ≠, percent key or the PLU/UPC key by pressing the ( ),
|, «
and/or »keys before those keys. After each entry is
completed, the programmed tax status of each key is resumed.
Selling the following items for cash with their programmed tax status reversed
• One $13.45 item of dept. 7 (non-taxable) as a taxable 1 item
• One $7.00 item of dept. 2 (non-taxable) as a taxable 1 and 2 item
• One $4.00 item of dept. 3 (taxable 2) as a non-taxable item
• Two $10.50 items of dept. 1 (taxable 1) as taxable 2 items
The entry of a multi-taxable item for PST or GST will be prohibited as follows (for Canada).
In case of; Tax 1: PST, Tax 2: PST,
Tax 3: GST, Tax 4: GST Taxable 1 and 2 item ········· prohibited Taxable 1 and 3 item ············· allowed Taxable 2 and 3 item ············· allowed Taxable 1 and 4 item ············· allowed Taxable 2 and 4 item ············· allowed Taxable 3 and 4 item ········· prohibited
In case of; Tax 1: PST, Tax 2: PST,
Tax 3: PST, Tax 4: GST Taxable 1 and 2 item ········· prohibited Taxable 1 and 3 item ········· prohibited Taxable 2 and 3 item ········· prohibited Taxable 1 and 4 item ············· allowed Taxable 2 and 4 item ············· allowed Taxable 3 and 4 item ············· allowed
Note
1345
\ 7
700
\ |2
400
|3
1050
\ |1
1 a
PrintKey operation
Example
TAX1
SHIFT
TAX
SHIFT
TAX
SHIFT
TAX
SHIFT
TAX
SHIFT
Please note that the previous balance key (ufor ER-A520 and for ER-A530) is shown as u.
Two different guest check entry systems are available: the GLU system and previous balance lookup (PBLU) system. It depends on how your register has been programmed which of these is used. Please contact your authorized SHARP dealer for more information about this selection. GLU system: If this system is selected, the balance due and the details of the order are placed in the guest
check file. The information can be automatically recalled by pressing the key, or enteringa GLU code when additional ordering or finalization is required.
PBLU system: If this system is selected, the previous balance is stored in the previous balance lookup file
(PB lookup file). The information can be automatically recalled by entering a previous balance lookup code (a PBLU code) when additional ordering occurs.

GLU/PBLU system

New guest
For a new guest;
• The GLU/PBLU code refers to a number/code that will be used whenever the guest check must be accessed for re-ordering or final payment.
• The available range of GLU or PBLU codes can be programmed for each chashier/server.
• Your register can be programmed to generate GLU/PBLU codes in a sequential fashion. If your register has not been programmed to do so, each GLU/PBLU code can be entered manually.
• The cover count refers to the number of people in the party. When the cover count entry is compulsory, you must enter the cover count (max. 2 digits). When cover count is not compulsory, enter the cover count and press the key.
• When the
S
key is pressed, the tax is not calculated.
• You can temporarily finalize a guest check by pressing the
f
key. In the GLU system the check will show the current balance including tax while the tax amount is not added to the GLU/PBLU file, and when an additional order is made, the tax amount is recalculated. In the PBLU system, the check will show the current balance including tax and the tax amount is added to the GLU/PBLU file (charge posting), while the guest check is still open.
CV
CNT
Note
For automatic GLU/PBLU code generation
Amount
n
S f
r
or
[Item entries]Cover count entry
Partial tendering
GLU/PBLU code
(1-9999)
A
[Payment operations]
Procedure

Guest Check (GLU/PBLU)

6
48
Note
PBAL
GLU
RECALL
GLU recall
Each cashier/server can recall their GLU/PBLUs for reorder or settlement by pressing the key. The register display GLU/PBLUs from the smallest GLU/PBLU number. Follow the procedure to recall GLUs and select a desired GLU/PBLU code.
* When the largest opened GLU/PBLU number is displayed, the smallest GLU/PBLU number is displayed when
the key is pressed.
Opened GLU: #111/#112/#113 Selecting GLU#113 and making sales entry of two dept. 7 items ($3.00 and #5.00)
u
300
7
500
7
f
PrintKey operation
Example
#/
TM
L
:To cancel GLU recall
:To go to the following GLU/PBLU*
:To select
GLU/PBLU code
A GLU/PBLU code and the total amount are displayed.
GLU
RECALL
u
#/
TM
Procedure
GLU
RECALL
Not printed when the S key is pressed instead of the
f
key.
111
n
2
2
3500
2
2700
3
f
PrintKey operation
Example
49
CV
CNT
GLU
RECALL
#/TM#/
TM
Get ready for sales entry
Reorder entries
For making additional guest check entries, use the following procedure:
Settlement
Use the following procedure:
• You can make a tip-in entry before a tender entry. If a tip-in entry is made, the tip amount must be tendered by using the associated media key e.g. CH1 thru CH9 for the charge tip and CASH 1 or CASH 5 for the cash tip.
• Partial tendering is prohibited after tip-in entry operation.
Note
111
u
5000
k
2000
c
PrintKey operation
Example
u
[Item entries]
GLU/PBLU code
(1-9999)
[Payment operations]
Procedure
111
u
1400
5
1600
6
3000
r
c
PrintKey operation
Example
Amount
S f
r
or
[Item entries]
GLU/PBLU code
(1-9999)
A
[Payment operations]
u
Partial tendering
Procedure
50

Deposit entries

Deposit refers to a payment on a charge account. It can be received in cash, check or by charge. You can make the deposit entry only while in a guest check transaction. It cannot be done during handling of a tendered amount. A received deposit can be refunded by pressing the key. You cannot attempt to refund an amount larger than the deposit balance.
To record a $50.00 deposit in cash made by a customer with PBLU code 111
To refund a $50.00 deposit made by a customer with PBLU code 111
111
u
5000
5
Å
S
PrintKey operation
Example
111
u
5000
5
Å
S
PrintKey operation
Example
Deposit amount
c
É
k
h
thru
thru
thru
DEPO
DEPO RFND
CHK5
CH9
Procedure
DEPO RFND
51
DEPO
DEPO
RFND
52

Transferring guest checks out or in (Transfer-out/in)

Transferring guest checks out
At the end of a cashier/server shift or whenever a cashier/server is relieved, one or more open guest checks can be transferred from the cashier/server to the open check file until the responsibility for the check(s) is assigned to another cashier/server.
GLU#111 is transferred out.
Transferring guest checks in
When the second cashier/server is assigned to be responsible for guest checks that have been transferred out:
GLU#111 is transferred in.
111
u ”
PrintKey operation
Example
For the next guest check
GLU/PBLU code
(1-9999)
”u
Only when cover count entry is non-compulsory
Cover count entry
(2 digits)
(new cashier/server sign-on)
CV
CNT
Procedure
111
u ’
PrintKey operation
Example
(cashier/server sign-on)
For the next guest check
GLU/PBLU code
(1-9999)
’u
Procedure
53

Bill totalizing/bill transfer

Bill totalizing
The bill totalizing function is used to totalize multiple bills when, for example, a particular guest pays not only his or her bill, but also the bills of other guests.
Totalizing GLU#112 and GLU#113 to GLU#111
• All #1 bills are added to a #2 bill. A maximum of 5 bills may be added to a #2 bill.
• The GLU/PBLU code of #1 must be in use. If the guest check(s) of #1 or #2 has already been handled by another server, the guest check(s) must have been made “Transferring out.”
Note
j
112
u
113
u
111
s
S
PrintKey operation
Example
GLU/PBLU code
#1 bill
j u
GLU/PBLU code
#2 bill
s
S f
[Sales entries]
[Payment operations]
Procedure
54
Bill transfer
This function is used to change the GLU/PBLU code of a particular bill.
GLU#111 is transferred to GLU #120.
• This function requires that the current GLU/PBLU code be entered for #1 and a new GLU/PBLU code be entered for #2.
• A #1 bill is transferred to a #2 bill. The #1 bill is then cleared and set free.

Bill separating

The function is used when each guest of a group pays his or her own order. With this function, you can select some items from a guest check and make an entry for the payment. Also, you can transfer the items you have selected to other guest checks. This function is available only in the GLU system.
ub u
GLU code (For receiving)
GLU code
(Original GLU code)
[Payment operations]
An item of the original GLU and its quantity are displayed.
#/
TM
To go to the following item
Q'ty
S b
@
f
To enter total q'ty
To terminate
b
To terminate
Procedure
j
111
u
120
s
S
PrintKey operation
Example
GLU/PBLU code
#1 bill
j u
GLU/PBLU code
#2 bill
s
S f
[Sales entries]
[Payment operations]
Procedure
Note
55
One of the dept. 9 items is separated from GLU111 (three dept. 7 items and three dept. 9
items are entered.)

Manual Previous Balance (PB) and Credit Balance (CB) entry

The register allows you to make manual PB/CB entries. If you use this function, the previous balance amount is entered manually when making new entries that will adjust the original total.
This function is not available when you use GLU or PBLU system. To use this function, please contact your authorized SHARP dealer.
New customers
For a new customer, use the following procedure:
When the
S
or fkey is pressed, the tax is automatically calculated and printed. The tax is then
added to the balance and the new balance is printed.
Making a service entry for a dept. 5 item ($87.50) and a dept. 6 item ($62.50) item for a new
customer. (A non-add code is used to identify the customer.)
n
13579
u
8750
5
6250
6
S
PrintKey operation
Example
Note
n Sf
[Item entries] or
Procedure
Note
b
111
u
117
u
1
@
S
b
PrintKey operation
Example
#/
TM
#/
TM
Dept. 7 item label and the q’ty are displayed. To skip dept. 7 items Dept. 9 item label and the q’ty are displayed. To select one of dept. 9 items
56
Customer with previous or credit balance
To enter a charge to a customer with a previous or credit balance, use the following procedure:
*
1
Check digit: The number which is printed at the right of the word “SERVICE” on the receipt of the previous
entry. (See the previous page. Check with your authorized SHARP dealer for activation of the check digit feature.)
*
2
Previous balance: In case that the balance is plus or zero
*
3
Credit balance: In case that the balance is negative
To make a service entry of 5 dept 7 items (unit price $25.00) for the customer account from the previous example. (non add code number 13579), which has the previous balance $150.00.
Settlement
Use the following procedure:
The customer (the non add code number 13579) whose previous balance is $275.00 is $27500 pays $200.00 in check and $75.00 in cash.
3 27500
u
13579
5
20000
k
7500
a
PrintKey operation
Example
Previous balance
u
Check digit
(Optional)
[Item entries ]
Credit balance
n
[Payment operation]
Procedure
3 15000
u
13579
5
5
@
2500
7
S
PrintKey operation
Example
Previous balance
*2
u
Check digit
*1
(Optional)
[Item entries ] or
Credit balance
*3
n
Sf
Procedure
Check digit
Check digit
#/TM#/
TM
57

Percent calculations (premium or discount)

• Your register provides the percent calculation for the merchandise subtotal and item entries. You need to specify in advance whether the register should perform the percent calculation based on the merchandise subtotal or each item entered.
• Percentage: 0.01 to 99.99%
Percent calculation for the merchandise subtotal
Selling four $1.40 items of dept. 5 and two $2.25 items of dept. 6; all these items are sold for cash at a premium of 10% (This example presumes that a premium of 10% has been programmed for the
%
key.)
Percent calculation for item entries
Selling for cash an $8.00 item of dept. 6 at a discount of 15% and another $5.00 item of PLU 90 at a discount of 7.5% (This example presumes that a discount of 15% has been programmed for the
§
key.)
800
6
§
90
P
7 .5
§ a
PrintKey operation
Example
4
@
140
5
225
6 6 Â % a
PrintKey operation
Example

Auxiliary entries

7
PLU/ UPC

Discount entries

For discount or coupon tenderings, you may use the -thru ±key. If the discount or tendered coupon is the one applicable to sales, use the vendor coupon or if it is applicable to each department key, use the store coupon.
Discount for the merchandise subtotal
Selling a $5.75 item of dept. 6 and another $7.50 item of PLU 80 for cash after subtracting the discount amount $1.00 from the total sale amount (This example presumes that the vendor coupon has been programmed for the
key.)
Discount for item entries
Selling a $6.75 item of dept. 5 for cash after subtracting the coupon amount 75¢ (This example presumes that the store coupon has been programmed for the
-
key.)
*
The -is entered as a modifier for the department which will be netted by the coupon amount. Such item netting coupon entries may generally be entered at any point within a transaction. Two lines are printed for each entry: The first is the label programmed for the
-
function and the
second is related department and
-
amount.
Note
675
5
75
-
5 a
PrintKey operation
Example
Amount
à
Amount
Direct PLU
Dept.
Dept. code
PLU code
-
thru
±
-
thru
±
-
thru
±
à
Amount
or
å
PLU/ UPC
or
å
PLU/ UPC
UPC code
-
thru
±
-
thru
±
PLU/ UPC
Ä
Procedure
575
6
80
P
100
– a
PrintKey operation
Example
58
PLU/ UPC
*
59

Refund entries

If a refund item is the one entered into a department, enter the amount of the refund, then press the Ïkey and the corresponding department key in this order; and if an item entered into a PLU (or UPC) is returned, enter the corresponding PLU (or UPC) code, then press the
Ï
and keys, or press the Ïand direct PLU keys
without entry of PLU code, in this order.
Receiving the following items returned: One $2.50 item of dept.5 and seven $2.10 items of PLU 13

Return entries

If a return item is the one entered into a department, enter the amount of the return, then press the key and the corresponding department key in this order; and if an item entered into a PLU (or UPC) is returned, enter the corresponding PLU (or UPC) code, then press the and keys, or press the and direct PLU keys without entry of PLU code, in this order.
Receiving the following items returned: One $3.00 item of dept 1 and one $3.25 item of PLU15
The returned items are not subjected to the calculation for dept./PLU/UPC items (quantity and amount) on the sales reports.
Note
300
Ï 1
15
Ï t
a
PrintKey operation
Example
RETURN
PLU/
UPC
RETURN
RETURN
250
Ï5
7
@
13
Ï P
a
PrintKey operation
Example
PLU/
UPC
PLU/
UPC
RETURN
PLU/
RETURN
UPC
60

Refund sales mode

This function is used for those item return entries relating to departments, PLUs/subdepartments and UPCs. Pressing the
˜
key at the beginning of a transaction causes the register to enter the REFUND SALES mode. All of the REFUND SALES mode entries are automatically handled as refund entries. This mode cannot be finalized by check payment entry.
Receiving the following items returned: One $2.50 item of dept.5 and seven $2.10 items of PLU 13

Printing of non-add code numbers

Enter a non-add code number such as a customer’s reference number within a maximum of 16 digits and press the key at any point during the entry of a sale. Your register will print it at the time of entry.
Selling a $15.00 item of dept. 5 by charge account to a customer whose code number is 1230
1230
=
1500
5
h
PrintKey operation
Example
#/
TM
˜
250
5
7
@
13
P
a
PrintKey operation
Example
PLU/ UPC
#/
TM
61

Gratuity

Calculation
When the payment operation is made for sales registrations, the gratuity amount is calculated and printed. You can program a percent rate for calculating the gratuity. If the percent rate is programmed as 0%, the register does not print any gratuity. You can program a tax status (taxable 1/taxable 2/taxable 3/taxable 4/non-taxable) for gratuity.
When a percent rate of the gratuity is programmed as 10%:
Exemption
Your register allows you to exempt a customer from the gratuity by pressing the key prior to a payment operation.
When a percent rate of the gratuity is programmed as 10%:
1250
5
1000
6
a
PrintKey operation
Example
GRT
EXEMPT
500
5 a
PrintKey operation
Example
GRT
EXEMPT
62

Tip-in entries

Your register allows the entry of tips that your guests give to cashiers/servers in cash or by credit card. A tip entry must be done before a payment entry. You must use the corresponding media key e.g. CH1 thru CH9 for the charge tip and CASH 1 or CASH 5 for the cash tip. Two different tip-in entry systems are available: the tip amount entry system and the tip percent rate entry system. It depends on how your register has been programmed which of these systems is used.
Receiving $3.00 by cash as a tip
PrintKey operation
Example
Tip amount
When you use a programmed percent rate
Tip amount entry system:
CA TIP
CH TIP
Tip percent rate
(0.01 - 99.99)
Tip percent rate entry system:
CA
TIP
CH TIP
Procedure

Payment treatment

8
CA TIP
300
a
63

Tip editing

This function is used for entering tip amounts after finalizing a guest check with a charge tender. This is only available when the guest check transaction is finalized through CAT authorization and the tip is to be paid in charge tender. The bill number which is issued when the
S
or fkey is pressed in guest check entry must be used in order to identify the guest to edit or add tip amount. For the operation, press the key. When the display prompt appears, enter the bill number and press the
u
key, then enter tip amount and press the key again. To use the tip editing function, please consult your authorized SHARP dealer.

Tip paid entries

This operation is used when tips that guests have paid by using credit card are paid to respective cashiers/servers in cash. To perform a tip paid entry, enter the cashier/server code, then press the
key.
You can prohibit the tip paid operation in the REG mode by the PGM2 programming.
When the tip amount remains unchanged in Individual Server Resetting, the tip paid function is automatically executed and tip receipt is issued to the report printer prior to report printing.
ED TIP
ED TIP
Note
64

Currency conversion

Your register allows payment entries of foreign currency. Pressing the çthru $key creates a subtotal in foreign currency. Cash payment is the only media that can be handled after currency conversion.
*Rate: 0.000000 to 999.999999
When the amount tendered is short, the deficit is shown in domestic currency.
To convert the amount owed ($69.50) into the designated foreign currency
Preset rate (1.325) - CONV 1
Manual rate - CONV 4 (The
$
key can be used only for the manual entry.)
Conversion rate
2300
6
4650
7
1 .275
$
10000
a
PrintKey operation
Conversion rate Foreign currency
Domestic currency
Domestic currency
2300
6
4650
7 ç
10000
a
Currency conversion
Amount tendered in foreign currency
PrintKey operation
Example
Note
ç "
# $c
a Å É
*Rate
Reentry
Preset rate
Amount tendered (max. 8 digits)
For direct finalization
After an entry is completed or After the amount tendered is found smaller than the sales amount in a sales entry.
Next registration or payment in domestic currency
thru
For an additional payment in foreign currency
Procedure
65

Received on account entries

A customer whose reference number is 12345 tenders $48.00 by check for received on account.

Paid out entries

You pay $30.00 by check to a vendor whose code number is 6789.

No sale (exchange)

Simply press the nkey without any entry. The drawer will open and the printer will print “NO SALE” on both the journal and the receipt. If your machine is preset to print a non-add code number before pressing the
n
key, a no sale entry is achieved with a non-add code number printed.
6789
=
3000
p k
PrintKey operation
Example
Amount (max. 8 digits)
p
or
π
k
É
,
thru
thru
thru
f
,
CHK2 CHK5
CH9CH1
Procedure
12345
=
4800
r k
PrintKey operation
Example
Amount (max. 8 digits)
r
or
®
k
É
,
thru
thru
thru
f
,
CHK2 CHK5
CH9CH1
Procedure
#/
TM
#/
TM
66

Cashing a check

Enter the check amount, then press a check key (k, thru ).
Cashing a check of a $30.00 amount

Bottle return

This function is used to handle the payment (paid out) for returned empty bottles or cans.
You pay for ten 15¢ returned empty bottles. (This example presupposes that dept. 10 has been programmed as bottle return department.)
You can achieve many different key sequences automatically with a single key depression by using an automatic sequencing key (
~
thru ).
Performing the transaction “Selling a $5.00 item (dept. 7) for cash” programmed for the
¡
(¡= 500
7a
)
¡
PrintKey operation
Example
10

Automatic sequencing key entries

9
PrintKey operation
Example
6789
=
3000
k
PrintKey operation
Example
Check amount
Non-add code number
k
thru,
CHK2 CHK5
#/
TM
Procedure
CHK5
CHK1
#/
TM
10
@
10
15
a
67
This mode is used to throw away an article which has already been prepared and is no longer serviceable.
Wasting 10 PLU 35 items
• PLU/UPC entries are only allowed in the WASTE mode, and direct and indirect void operations are also allowed in this mode.
• When a WASTE mode transaction is finalized, the drawer does not open.
• The consecutive number is incremented every WASTE mode transaction.
• When the WASTE mode is activated by pressing the key, the mode caption “WAST” is displayed.
WASTE
Note
PrintKey operation
Example
[Item entries ]

WASTE mode

WASTE
WASTE
Procedure
WASTE mode
10
WASTE
10 @ 35
PLU/
UPC
WASTE
68

CORRECTION

If you make an incorrect entry relating to a department, PLU/subdepartment, UPC, percentage (%through
), deduction (-through ≠) or refund, you can correct this entry by pressing the vkey immediately after
the incorrect entry.
With the
v
key, you can void any incorrect department, PLU/subdepartment, UPC or item refund entry made
during a transaction if you find it before finalizing the transaction (e.g. pressing the
a
key). This function is applicable to department, PLU/subdepartment, UPC and item refund entries only. For the operation, press the
v
key just before you press a department key, àkey, direct PLU key, key or
just before you scan a UPC code. For the refund indirect void, press the
v
key after you press the
Ï
key.
1310
6
1755
7
10
P
ô
58
P
825
7
5012345678900
P
1310
v6 v
ô
58
v P
5012345678900
v P
a
PrintKey operation
Example
PLU/
UPC

Correction of the next-to-last or earlier entries (indirect void)

2
1250
6 v
2
P
v
5012345678900
P
v
600
8
§ v
328
9
28
-9 v
250
Ï
8 v a
PrintKey operation
Example

Correction of the last entry (direct void)

1
PLU/ UPC
PLU/ UPC
PLU/
UPC
PLU/
UPC
PLU/
UPC
PLU/
UPC
PLU/
UPC
You can void an entire transaction. Once the subtotal void is executed, the transaction is aborted and the register issues a receipt.
Any errors found after the entry of a transaction has been completed or during an amount tendered entry, cannot be voided. These errors must be handled by the manager. The following steps should be observed:
1. If you are in the middle of making an amount tendered entry, you must first finalize the transaction before
making corrections.
2. Try to make correct entries from the beginning.
3. Hand the incorrect receipt to your manager for its cancellation.

Correction of incorrect entries not handled by the direct or indirect void function

4
1310
1
1755
6
10
P
35
P
ı v ı
PrintKey operation
Example

Subtotal void

3
Subtotal void
69
PLU/ UPC
PLU/ UPC

CORRECTION AFTER FINALIZING A TRANSACTION (AFTER GENERATING A RECEIPT)

When you need to void incorrect entries that are found after finalizing a transaction or cannot be corrected by direct or indirect void, follow this procedure in the MGR mode.
1. Turn the mode switch to the MGR position.
2. Press the
v
key to put your register in the VOID mode.
3. Repeat the entries that are recorded on an incorrect receipt. (All data for the incorrect receipt are removed
from register memory; the voided amounts are added to the void register totalizer.)
Your machine leaves the VOID mode whenever a transaction is canceled (i.e. finalized in the VOID mode.) To void additional transactions repeat steps 2. and 3. above.
Note
Cancellation receiptIncorrect receipt
70

OVERRIDE ENTRIES

Programmed limits (such as maximum amounts) for functions can be overridden by making the entry in the MGR mode.
1. Turn the mode switch to the MGR position.
2. Make the override entry.
Selling a $15.00 item (dept. 2) for cash and subtracting the coupon amount $2.50 from the sale amount (This example presumes that the register has been programmed not to allow coupon entries over $2.00.)
1500
2
REG-mode250
–2
...Error
entries
c
Turn the mode switch to the MGR position.
250
Return the mode switch to the REG position.
a
PrintKey operation
Example
Procedure
71
72

OVERLAPPED CASHIER/SERVER ENTRY

This function allows you to switch from one cashier/server to another interrupting the first cashier/server’s entry. The second cashier/server can make a sales entry, then the first cashier/server may continue.
Cashier 1: Entry started Cashier 2: Cashier/server change (1 to 2), interruption initiated Cashier 2: Transaction finished (2) Cashier 1: Cashier/server change (2 to 1), entry restart
• The overlapped cashier/server entry is not available while the tendering sale.
• If any cashier/server is still making an entry (or has not finalized the transaction yet), the machine does not run in any mode other than REG and MGR and X/Z reports can not be performed. The error message “SERVER ERR.” and the corresponding cashier/server code(s) are displayed at this time.
The entry by cashier/server 1 is started.
The entry by cashier/server 2 is started. (The entry by cashier/server 1 is interrupted.)
The transaction by cashier/server 2 is finalized.
The entry by cashier/server 1 is restarted.
The transaction by cashier/server 1 is finalized.
1. Cashier/server 1 is assigned.
(1‹)
100
1
360
3 3
2. Cashier/server 2 is assigned.
2
3
@
150
2 a
3. Cashier/server 1 is assigned.
1
100
1
360
3 a
CommentsKey operation
Note
Example

SPECIAL PRINTING FUNCTIONS

If your customer wants a receipt after you have finalized a transaction with the receipt ON-OFF function in the “OFF” status (no receipting), press the
q
key. This will make a copy receipt. Your register can also print a
copy receipt when the receipt ON-OFF function is in the “ON” status.
Pressing the
q
key in the OP X/Z mode before registration toggles the status “ON” and “OFF”.
Printing a copy receipt after making the entries shown below with the receipt ON-OFF function in the “OFF” status
When the receipt ON-OFF function is in the “ON” status and you press the
q
key to make a second copy
When the receipt ON-OFF function is in the ON status, the COPY symbol will be printed on the receipt.
Print on the receipt
Print on the journal
850
2
3
@
150
1 a
For receipting
q
PrintKey operation
Example
Note

Copy receipt printing

1
73
74
Your register can perform validation printing when it is connected with the slip printer. For the details about the slip printer, contact your authorized SHARP dealer.
1. Set a validation slip to the slip printer.
2. Press the
key. The validation printing will start.
When you make an entry for which compulsory validation printing can be overridden by performing the following operation. If you need this function, Contact your authorized SHARP dealer.
1. Move the mode key to the MGR position.
2.
This function is used for issuing bills to customers/guests. Your register can print bills on a slip printer or receipts on the register depending on the programming. You can issue bills when GLU/PBLU/Manual PB/CB entries are done only, for every entry or when a media key is pressed. For this selection, please consult your authorized SHARP dealer.
When bill printing is compulsory, the register will print a bill automatically in case it is to be printed on receipts and when a slip is inserted in case it is to be on a slip printer. When bill printing is non-compulsory, use the following procedure to print a bill.
This function is available immediately after the finalization of transaction (including after pressing the
S
or the fkey).
Your register can print the employee’s arrival and departure time when it is connected with the slip printer. For the details for connecting a slip printer, please contact your authorized SHARP dealer. For printing of the arrival and departure times, you must be in the OP X/Z mode.
Printing of arrival time
Printing of departure time
2
1
Printing of the employee’s arrival and departure times (Slip printer)
4
Note

Bill printing

3
.
Note

Validation printing function (Slip printer)

2
Bill on receipts Bill on the slip (auto feed)
XX
No. of lines of slip feed
75
As an optional setting, your register can print a graphic logo on the top of each receipt (header graphic logo). If preset to do so, a graphic logo can be printed on the bottom of each receipt (footer graphic logo) with the job code #2616. You can also print the graphic logos with the combination of 3-line header logo message or 3-line footer logo message. Printing only logo messages without the graphic logo is possible. Please consult your dealer when you want to change the setting.
• Sample receipt with a header graphic logo and a footer graphic logo
This function enables a partial order to be sent to the kitchen for preparation while the remaining order is still being placed.
Remaining items will be sent to the remote printer when the transaction is finalized.
When this function is used, the subtotal void operation is not allowed.
Item entry
Data transfer to the remote printer
RP
SEND
Example

Remote printer send function

6
Header graphic logo
Footer graphic logo

Printing of header and footer graphic logos

5

TIME DISPLAY AND AUTOMATIC UPDATING OF THE DATE

When you need the time displayed, turn the mode switch to the OP X/Z position after the preceding transaction or operation is finalized. You can also display the time by pressing the key in the REG or MGR mode.
The time display disappears as soon as you press the
c
key in the REG or MGR mode or begin the
subsequent entry.
Sample display of 10:25 AM
Once the internal clock unit is started at the correct time, it continues to run as long as the built-in battery is charged, and updates the date (month, day, year) automatically.

Automatic updating of the date

2
Date
Time
#/
TM

Time display

1
76
77

PRIOR TO PROGRAMMING

When you are in the PGM1 or PGM2 mode, the keyboard layout will be set to one of the programming layouts as shown below.
For ER-A520
For ER-A530
The programming keyboard sheet is transparent, allowing placement over the standard keyboard sheet.
The shaded area contains the character keys which are used for programming characters.
Î
: Used to enter the double-size character.
Ó
: Used to change a lower-case letter/upper-case letter.
é
: Used to select a symbol. (ER-A520 only)
: Used to back up the cursor for deleting.
/
: Used to enter a space. : Used to enter a numeric character. (ER-A520 only)
(NUM)
Note

Programming keyboard layout

1
FOR THE MANAGER
Æ
æ
c
l
To enter the letter “ ”, press
éé
To enter the upper-case letter “Æ Æ”, press
To enter the lower-case letter “æ æ”, press
ÓÓ
clc
l
Æ
æ
c
l
Æ
æ
c
l
Æ
æ
c
l
Æ
æ
c
l
Æ
æ
c
l
Æ
æ
c
l
RECEIPT
1
Q
A
!
RECEIPT
( )
( )
)
(
(
)
SHIFT
)
JOURNAL
@
œ
2
AUTO
W
S
Z
JOURNAL
)
(
(
)
PO
( )
%
(
)
SHIFT-2
)(
#
3
E
D
X
(
SPACE
$
4
R
F
C
)(
(NUM)
@
FOR
78
456
1
0
%
5
T
G
V
L2
Y
^
6
H
B
(DC)
#
CL
9
2
3
00
Ñ
F
A
B
:
C
+
D
<
E
?
{
K
@
G
L
,
;
H
M
=
-
I
N
P t
>
J
O
[
}
”’ <?>
DEPT
&
#
7
CR2
CR1
U
J
N
6 2713
8
5
I
4
K
3
M
2
(
9
12
O
11
L
10
,
)
0
P
181925
;
17
.
=
+
-
33
26
@
FOR
:
78
456
$
P
/
Q
.
R
Ç
S
£
T
]
c
æ
l
BACK
( )
Æ
SPACE
&
%
X
U
(
)
Y
V
!
?
Z
W
SBTL
CA/AT/NS
CL
9
BACK
( )
SPACE
(
SHIFT
)
(DC)
SPACE)(SPACE
)
(
SPACE
)
(
SPACE)(SPACE
(
)
2
1
0
00
3
CA/AT
SBTL
78
You can program alphanumeric characters for departments, PLUs, UPCs, functions, etc. while in the character entry mode. There are two ways for programming characters: using character keys on the keyboard and entering character codes with the numeric keys on the keyboard.

Using character keys on the keyboard (keys on the shaded area)

Enter a character according to the position in the programming keyboard layout.
Entering alphanumeric characters
To enter a character, simply press a corresponding character key.
In case of ER-A520, “( )”, “(
ˆ
)”, “( ¨)”, “ ( `)”, “( ´)”, “( ´´)”, “( °)”, and “( ˜)” keys can be used in combination
with a character key. If the combination is unavailable, only a character key is entered.
[Ex.] “Å” :
➞➞
A
To enter a numeric character: (ER-A520) Press key and enter a number by ten keys (0 – 9).
[Ex.] Entering the character “135” :
135
(ER-A530) Simply press a corresponding numeric key in the shaded area. To enter a space, press the
/
key.
Entering double-size characters
Î
: This key toggles the double-size character mode and normal-size character mode. The default is the
normal-size character mode. The double-size character is displayed with the letter “=” (ex. =S). [Ex.] To program the name “SHARP” in double size :
Î
SHARP
Î
Entering lower-case letters
Ó
: You can enter a lower-case letter by using this key. Press Ókey just before you enter the lower-case
letter. This key also allows you to enter the characters/symbols shown at the upper right of keys. [Ex.] To program the name “Sharp” :
➞S ➞
Ó
harp
Ó
Entering symbols shown at the upper left of keys (ER-A520 only)
é
: You can enter symbols by using this key. Press ékey just before you enter the symbol.
[Ex.] To program the symbol “ ” :
é
➞➞
é
Editing text
You can edit the text you have entered by deleting characters.
: Backs up the cursor for deleting the character or figure at the left of the cursor.

Entering character codes

Numerals, letters and symbols are programmable by entering the ºkey and character codes. See the “Alphanumeric character code table” on the next page. In this way, you can program characters other than the characters shown in the programming keyboard layout.
XXX
º
XXX: Character code (3 digits)
Double-size characters can be made by entering the character code 253. [Ex.] To program the name “SHARP” in double size
253
º
083 º072 º065 º082 º080
º
(DC) S H A R P
Note

How to program alphanumeric characters

2
ˆ
(°)
(NUM)
(NUM)(NUM)
l
clc
c
l
c
l
79
Alphanumeric character code table
(DC) : Double-size character code
:
The shaded character cannot be displayed (will be displayed as space).
The character “ !!” (code: 128) is displayed as “! ”.
Note
Code
001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 026 027 028 029 030 031 032 033 034 035 036 037 038 039 040 041 042 043 044 045
Character
á â ê
î ì
í ô ó û ú
œ
u ú o ó
 
¨
  
 
U Ú O Ó
(space)
!
” # $
%
&
’ ( )
+
,
-
Code
046 047 048 049 050 051 052 053 054 055 056 057 058 059 060 061 062 063 064 065 066 067 068 069 070 071 072 073 074 075 076 077 078 079 080 081 082 083 084 085 086 087 088 089 090
Character
.
/ 0 1 2 3 4 5 6 7 8 9
:
; < = > ?
@
A B
C D
E F
G H
I J K L
M N O
P
Q R
S T
U
V
W
X Y Z
Code
091 092 093 094 095 096 097 098 099 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135
Character
Ä Ö Ü
^ _
a b c d e
f g h
i j
k
l
m
n o p q
r s
t u v
w
x y z
{
|
} ß ¢ !!
1
2
3
4
1/2 F/T
Code
136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 177 178 180 181 182 183 184 185 186 187 188 189 190 191 192
Character
F
T
ç
°
¿ Ù à
Æ
ø Å
¤
é è
Pt
i Ñ ò £ ¥
°
Á
Í A a E e
I
i U
u N n
C S
C
´´
´´
´´
´´
193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 253
I
G S G g K k L
l
Z D d C c
P
e s c z y u n
r
§ Ø
] [
ä ö ü
æ
å É ñ
*(DC)
.
.
.
.
.
.
. .
.
.
.
.
Code
Character
80

PROGRAMMING

This chapter illustrates how to program your cash register.

Basic instructions

All the programming items can be programmed by the Job-Code-Based Programming described later. Also your machine allows you to program some items using the Direct Programming, which does not require you to enter the job code. However, object keys (shown below) must be allocated on the keyboard. For the keys not allocated on the keyboard, you cannot use the direct programming.
Job-Code-Based Programming
Simplified procedure :

Direct Programming

Sample procedure :

Preparations for programming

1.
Plug your machine into a standard grounded AC outlet.
2. Turn the mode switch to the PGM1 or PGM2 position.
To set the mode switch to the PGM1 position, use the manager or submanager key; and to set it to the PGM2 position, use the manager key.
3. Check to see whether both journal and receipt rolls are present in the machine. If they are missing, install
journal and receipt paper rolls correctly referring to the procedure in “4. Installing and removing the paper
roll” under “OPERATOR MAINTENANCE”.
4. Program the necessary items into your machine.
Direct Programming

Date

Enter the month (one or two digits), day (two digits), and year (four digits : 2000 – 2099) in this sequence.
Date
08262004
=
PrintKey operation
Example
Date (seven or eight digits)
XXXXXXXX
#/
TM
Procedure
PGM 2PGM 1

Setting the date and time

1
Ç
Data entry
Ç
XXX
(Job code)
Data entry
.
@
(Object key)
#/
TM
81

Time

Set the time using the military time (24-hour) system. For example, when the time is set to 2:30 AM, enter 230; and when it is set to 2:30 PM, enter 1430. The time will be printed and displayed using a real-time system. Once you set the time, the internal clock unit will continue to run as long as the built-in battery is alive and update the date (day, month, year) properly.
Your machine is equipped with 20 (ER-A520)/10 (ER-A530) standard departments and a maximum of 99 departments. Your machine allows you to perform the following programming for each department.

Unit price

Unit price
1000
1
Ç
PrintKey operation
Example
ı
à
Ç
Unit price (max. 6 digits)
Dept. code (1 — 99)
To program the next sequential dept.
To program any dept.
To program zero
1
Unit price (max. 6 digits)
To program zero
·
99
Procedure
PGM 2PGM 1

Programming for departments

2
Time
1430
=
PrintKey operation
Example
Time (max. four digits)
XXXX
#/
TM
Procedure
PGM 2PGM 1
#/
TM
82

Functional selection

*1Item: Selection: Entry:
A Group number 0 thru 9 (0: Non group) B Commission group number 0 thru 9 (0: Non commission) C Sign (plus/minus) Plus 0
Minus 1
D Food stamp status Ineligible 0
Eligible 1
E Tax 4 status Non-taxable 0
Taxable 1
F Tax 3 status Non-taxable 0
Taxable 1
G Tax 2 status Non-taxable 0
Taxable 1
H Tax 1 status Non-taxable 0
Taxable 1
I Item validation printing Non-compulsory 0
Compulsory 1
J Tare table number 0 thru 9 (0: not used) K Scale entry Inhibit 0
Enable 1 Compulsory 2
L Registration type Normal 0
SICS (Single Item Cash Sale) 1 SIF (Single Item Finalization) 2
M Department type Normal department 0
Hash department 1 Bottle return department 2 Gas department 3
N Type of unit price entry Inhibit department key 0
Open only 1 Preset only 2 Open and preset 3
O Significant digit for HALO 1 thru 9 P Number of zeros to follow the significant digit for HALO 0 thru 7
à
Ç
*1 ABCDEFGHIJKLMNOP
Dept. code (1 — 99)
To program the next sequential dept.
To program any dept.
To set all zeros
*1 ABCDEFGHIJKLMNOP
To set all zeros
@
@
1
·
99
Procedure
PGM 2
83
Group number
You can assign a department to a maximum of nine groups. This programming enables you to take group sales reports.
Commission group number
A commission group number (0–9, 0: non commission) can be assigned to each department.
Sign (plus/minus)
Assign a plus sign to departments for normal sales transactions.
Assign a minus sign to departments for minus transactions.
Food stamp status
Assign a food stamp status (food stamp eligible or food stamp ineligible) to each department.
Tax status (taxable 1 thru 4/non-taxable)
When an entry of a taxable department is made in a transaction, tax is automatically computed according to the associated tax table or rate.
Tax 4 is prohibited if you use the food stamp function.
Item validation printing
If item entries must be validated, program corresponding departments for compulsory validation printing.
Tare table number
Tare table number associated with scale entry (1 thru 9).
Scale entry
Program a department for scale entry when your store requires items to be sold by weight and are placed on a scale connected to the register.
Registration type
If an entry of a department programmed for SICS is made first, the sale will be finalized as soon as the department key is pressed. If the entry is made after entering a department not programmed for SICS, the sale will not be finalized until the
Ç
key is pressed.
Whenever a sale is made to a department programmed for SIF, the sale is finalized as soon as the department key is pressed.
Department type
You may program each department as one of the following three types.
Normal department
Hash department
A hash department is used to enter the amount of a special “sale”, such as a gift certificate sale or for the receipt of payment for utility bills, theatre tickets, etc., i.e. “non-sales” registrations. Any amounts entered in this department are not added to the grand total except tax amounts.
Bottle Return (BR)
Gas department
The gas department enables you calculate the quantity of gas sold in gallon by using a preset unit price when the sale amount of gas is entered. (quantity of gas = sales amount entered / preset unit price) Also gas discount can be automatically applied to the sales. (discount amount = total amount of gas x reduced unit price for each media; cash/check/charge)
Type of unit price entry
You may select one of the following four types of unit price entry for each department.
Open and preset
Preset only
Open only
Inhibit department key
HALO (High Amount Lockout)
You can set an upper limit amount (HALO) for each department. The limit is affective for the REG mode operations and can be overridden in the MGR mode.
OP” is the same as O
×
10
P
For example, presetting 14 ($100.00) here means that amount entries of up to $100.00 are allowed in the REG mode. When you preset 17, the upper limit amount is 99999.99.
Note
84
Your machine is equipped with 2000 standard PLU/UPC codes. Your machine allows you to perform the following programming for each PLU/UPC.
• Please note that the price lookup/subdepartment/UPC key (
P
for ER-A520) is shown as .
• To review the UPC codes available to this register, please refer to the chapter 13 in “Universal
Product Code(UPC) or European Article Number(EAN)”.
Ä
in Procedures indicates that you scan a barcode.

Unit price

* In case that price shift function is allowed, the register prompts to enter a unit price for the following level by
displaying “P2” thru “P6” on the display, and when a unit price of level 6 is entered, the register goes to the status for programming the following PLU/UPC. When you press the
Ç
on the way of programming multiple
prices for a PLU/UPC code, prices for the remained levels are kept unchanged. In case that single price entry is allowed for a PLU/UPC code, the register goes to the status for programming the following PLU/UPC.
Unit price
(In case of single price entry)
1 P1000
ı Ç
PrintKey operation
Example
Ç
PLU code (max. 5 digits)
* To program unit price 2 thru 6 (only when price shift function is allowed.) To program for the following PLU/UPC
To program any PLU/UPC
To keep current setting
l
Direct PLU key
Unit price 1
(max. 6 digits)
ı
PLU/ UPC
Ä
UPC code (6 to 13 digits)
5
Level no.
(1 to 5)
ä
Procedure
PGM 2PGM 1

PLU/UPC programming

3
Commission group no.
HALO
Taxable1
Food stampstatus F:Eligible
(None):Ineligible
IJKLMN
Group no.
1000000100000317
@ 1
Ç
PrintKey operation
Example
PLU/ UPC
Note
PLU/ UPC
85

Functional selection

*1Item: Selection: Entry:
A Commission group number 0 thru 9 (0: Non commission) B Sign (plus/minus) Plus 0
Minus 1
C Food stamp status Ineligible 0
Eligible 1
D Tax 4 status Non-taxable 0
Taxable 1
E Tax 3 status Non-taxable 0
Taxable 1
F Tax 2 status Non-taxable 0
Taxable 1
G Tax 1 status Non-taxable 0
Taxable 1
H Tare table number 0 thru 9 (0: Not used) I Scale entry Inhibit 0
Enable 1 Compulsory 2
J Type of unit price entry Prohibit mode 0
Open price only 1 Preset price only 2 Open price and preset price 3 Delete mode 4
Commission group number
A commission group number (0–9, 0: non commission) can be assigned to each department.
Sign (plus/minus)
The function of every PLU/UPC varies according to the combination of its sign and the sign of its associated department as follows:
Sign
Function of PLU/UPC
Department PLU/UPC
++Serves as a normal plus PLU/UPC ––Serves as a normal minus PLU/UPC +–Accepts store coupon entries, but not split-pricing entries –+Not valid; not accepted
Food stamp status
Assign a food stamp status (food stamp eligible or food stamp ineligible) to each PLU/UPC.
Note
Ç
To program for the following PLU/UPC
To program zero
@
*1 ABCDEFGHIJ
PLU code (max. 5 digits)
To program any PLU/UPC
l
Direct PLU key
PLU/ UPC
Ä
UPC code (6 to 13 digits)
5
Level no.
(1 to 5)
ä
Procedure
PGM 2
86
Tax status (taxable 1 thru 4/non-taxable)
When an entry of a taxable PLU/UPC is made in a transaction, tax is automatically computed according to the associated tax table or rate.
Tax 4 is prohibited if you use the food stamp function.
Tare table number
Tare table number associated with scale entry (1 thru 9).
Scale entry
Program a PLU/UPC for scale entry when your store requires items to be sold by weight and are placed on a scale connected to the register.
Type of unit price entry
You may select one of the following four types of unit price entry for each PLU/UPC.
Open price and preset price (for only PLU)
Preset price only
Open price only (for only PLU)
Prohibit mode: Prohibits the entry of any assigned PLU/UPC code.
Delete mode: Deletes data programmed for each PLU/UPC.

Associated department

Associated dept. code
1
P 1
Ç
PrintKey operation
Example
Ç
To program for the following PLU/UPC
To program any PLU/UPC
To delete the entered PLU/UPC
à
Associated department code
(1 – 99)
v
1
·
99
PLU code (max. 5 digits)
l
Direct PLU key
PLU/
UPC
Ä
UPC code (6 to 13 digits)
5
Level no.
(1 to 5)
ä
Procedure
PGM 2PGM 1
1 P0000001003
@ Ç
PrintKey operation
Example
PLU/ UPC
PLU/ UPC
Taxable1
(HIJ)
Commission group no.
87

Discount amount

Functional programming

* Item: Selection: Entry:
A Food stamp status Ineligible 0
Eligible 1
B Tax 4 status Non-taxable 0
Taxable 1
C Tax 3 status Non-taxable 0
Taxable 1
D Tax 2 status Non-taxable 0
Taxable 1
E Tax 1 status Non-taxable 0
Taxable 1
F Sign (+/-) Plus 0
Minus 1
G Vendor/store coupon selection Vendor coupon (subtotal _)0
Store coupon (item _)1
H Significant digit for HALO 1 thru 9 I Number of zeros to follow the significant digit for HALO 0 thru 7
-
±
Ç
*ABCDEFGHI
To program zero
@
To program any coupon function
Procedure
PGM 2
1000
­Ç
PrintKey operation
Example
-
±
Ç
Discount amount (max. 6 digits)
To program zero
Procedure
PGM 2PGM 1
Programming for discount keys (-)
4
Discount amount
88
Tax status (taxable 1 thru 4/non-taxable)
Tax 4 is prohibited if you use the food stamp function.
HALO (High amount lockout) HI” is the same as H x 10
I
. For example, presetting 14 ($100.00) here means that amount entries of up to $100.00 are allowed in the REG mode. When you preset 17, however, the upper limit amount is 99999.99. When you preset 00, the open amount entry is prohibited.

Percent rate

* Rate: Percent rate: 0.00 – 100.00
You must use a decimal point key when setting percentage rates that are fractional.
Percent rate
10 .25
% Ç
PrintKey operation
Example
Note
Ç
*
Rate
()
To program zero
Procedure
PGM 2PGM 1
Programming for percent keys (%)
5
HALO
Subtotal
_
Food stamp status F:Eligible
(None):Ineligible
Taxable 1
000011013
@-
Ç
PrintKey operation
Example
Note
89

Functional programming

* Item: Selection: Entry:
A Type of amount entry Inhibit percent key 0
Open only 1 Preset only 2
Open and preset 3
B Food stamp status Ineligible 0
Eligible 1
C Tax 4 status Non-taxable 0
Taxable 1
D Tax 3 status Non-taxable 0
Taxable 1
E Tax 2 status Non-taxable 0
Taxable 1
F Tax 1 status Non-taxable 0
Taxable 1
G Sign (+/-) Plus 0
Minus 1
H item%/subtotal% selection Subtotal % 0
Item % 1
I Always enter 0. 0 J Always enter 0. 0
Tax status (taxable 1 thru 4/non-taxable)
Tax 4 is prohibited if you use the food stamp function.
Subtotal %
Taxable 1
3000011000
@%
Ç
PrintKey operation
Example
Note
Ç
*ABCDEFGHIJ
To program zero
@
()
Procedure
PGM 2
90

Currency conversion rate

* Conversion rate: 0.0000 – 9999.9999
You must use a decimal point key when setting conversion rates that are fractional.

High amount lockout (HALO)

The HALO limit effects REG mode operations but can be overridden in the MGR mode. The HALO limit is represented by two figures as follows:
“AB” is the same as A × 10
B
. A: Significant digit (0 through 9) B: Number of zeros to follow significant digit: (for RA or PO: 0 thru 9), (for manual tax: 0 thru 7)
13
@
r Ç
PrintKey operation
Example
r
A
Ç
AB
To program zero
(Only for manual entry)
p
π
@
or
or
Procedure
PGM 2
Programming for the r, p, and †keys
7
0 .8063
ç Ç
PrintKey operation
Example
Note
ç
#
Ç
*
Conversion rate
To program zero
Procedure
PGM 2PGM 1
Programming for conversion keys (ç)
6
91

High amount lockout (HALO) and functional selection

* Item: Selection: Entry:
A GLU/PBLU/Manual PB/CB entry Enable 0
Inhibit 1 Compulsory 2
B Short amount tender entry Enable 0
Disable 1
C Retention of closed GLU/PBLU file No 0
Yes 1
D Bill (slip) printing Non-compulsory 0
Compulsory 1
E Footer printing on receipt No 0
Yes 1
F Non-add code entry Non-compulsory 0
Compulsory 1
G Change enable (over tender enable) Enable 0
Disable 1
H Validation printing Non-compulsory 0
Compulsory 1
I Drawer opening Yes 0
No 1
J Amount tendered operation Optional amount tendered for cash or check 0
Inhibit amount tendered for charge 0 Compulsory amount tendered 1
K Significant digit for HALO 0 thru 9 L Number of zeros to follow the significant digit for HALO 0 thru 8
HALO (High amount lockout) KL” is the same as K
×
10L. For example, presetting 13 ($10.00) here means that amount entries of up to $10.00 are allowed in the REG mode. When you preset 18, however, the upper limit amount is 999999.99.
Note
Ç
*
ABCDEFGHIJKL
To program zero
s
@
(For
Ç
key)
h
CH9
k
CHK5
Å
É
Procedure
PGM 2
Programming for the Ç, Å, ', and kkeys
8
CA
92
A thru J
HALO
000000000015
@)
Ç
PrintKey operation
Example
93
Your machine has an automatic tax calculation feature which allows you to program four tax tables to avoid calculating incorrect tax amounts. Automatic tax calculations require you to program, in addition to the tax table, the tax status of each pertinent department, PLU/UPC, and function key.

The tax table (applicable to the add-on tax)

Sample tax table
New Jersey tax table: 6%
To program a tax table, first make a table like the right table shown above. From the tax table, calculate the differences between a minimum break point and the next one (A). Then, from the differences, find irregular cycles (B) and regular cycles (C and D). These cycles will show you the following items necessary to program the tax table:
T: The tax amount collected on the minimum taxable amount (Q) Q: The minimum taxable amount M1: The maximum value of the minimum breakpoint on a regular cycle (C).
We call this point “MAX point.”
M2: The maximum value of the minimum breakpoint on a regular cycle (D).
We call this point “MAX point.”
M: Range of the minimum breakpoint on a regular cycle: difference between Q and M1 or between M1 and
M2
Taxes
Range of sales amount
Minimum breakpoint
.00 .01 .02 .03 .04 .05 .06 .07 .08 .09 .10 .11 .12 .13
.01 .11 .23 .39 .57 .73 .89
1.11
1.23
1.39
1.57
1.73
1.89
2.11
Maximum breakpoint
.10 .22 .38 .56 .72 .88
1.10
1.22
1.38
1.56
1.72
1.88
2.10
2.22
to to to to to to to to to to to to to to
T Q
M1
M2
A: Difference between the minimum breakpoint and the next one (¢)
– 10 (0.11 - 0.01) 12 (0.23 - 0.11) 16 (0.39 - 0.23) 18 (0.57 - 0.39) 16 (0.73 - 0.57) 16 (0.89 - 0.73) 22 (1.11 - 0.89) 12 (1.23 - 1.11) 16 (1.39 - 1.23) 18 (1.57 - 1.39) 16 (1.73 - 1.57) 16 (1.89 - 1.73) 22 (2.11 - 1.89)
B: Non-cyclic
C: Cyclic-1
D: Cyclic-2
PGM 2

Programming for the automatic tax calculation function

9
To delete a tax table, use the following sequence:
*1 First figure: The first figure to be entered depends upon whether the difference between a minimum
breakpoint to be entered and the preceding minimum breakpoint is not less than $1.00 or more than 99¢. When the difference is not less than $1.00, enter “1,” and when it is not more than 99¢, enter “0” or nothing.
Second figure: The second figure depends upon whether your tax table is to be programmed as tax table 1,
2, 3 or 4. When your tax table is to be programmed as tax table 1, enter “1”; when it is to be programmed as tax table 2, enter “2”; when it is to be programmed as tax table 3, enter “3”; and when it is to be programmed as tax table 4, enter “4”.
*2 If the rate is fractional (e.g. 4-3/8%), then the fractional portion (3/8) would be converted to its decimal
equivalent (i.e. .375) and the resulting rate of 4.375 would be entered. Note that the nominal rate (R) is generally indicated on the tax table.
If you make an incorrect entry before entering the M in programming a tax table, cancel it with the
c
key; and if you make an error after entering the M, cancel it with the ıkey. Then program
again from the beginning correctly.
• Limitations to the entry of minimum breakpoints
Your register can support a tax table consisting of no more than 72 breakpoints. (The number of breakpoints is 36 maximum when the breakpoint difference is $1.00 or more.) If the number of breakpoints exceeds the register’s table capacity, then the manual entry approach should be used.
Programming the sample tax table shown on the previous page as tax table 1
You do not need to enter the trailing zeros of the tax rate (after the decimal point) but you do need to enter the decimal point for fractions.
Note
1
@
6
@
100
@
1
@
11
@
23
@
39
@
57
@
73
@
89
@
111
@ a
PrintKey operation
Example
Note
@ @ t
max. six digits (0.0001 - 99.9999%)
max. four digits
One- or two­digit number
Rate
M
*1
*2
@
@ @
max. six digits (0.0001 - 99.9999%)
max. four digits
One- or two­digit number
Rate
M
*1
*2
@
max. three digits
T
@
max. five digits
Q
@ Ç
Minimum breakpoint max. five digits
Repeat until the MAX point is entered.
@
Procedure
Tax rate M T Q
The first cyclic portion
M1 (MAX point)
94
95
• If the tax is not provided for every cent, modify the tax table by setting the tax for every cent in the following way.
When setting the tax, consider the minimum breakpoint corresponding to unprovided tax to be the same as the one corresponding to the tax provided on a large amount.
Sample tax table Modification of the left tax table Example 8%
From the modified tax table above; Rate = 8(%), T = $0.01 = 1¢, Q = $0.11 = 11¢, M1 = 1.11, M2 = 2.11, M = 100
Tax
Minimum
breakpoint
.00 .01 .02 .03 .04 .05 .06 .07 .08 .09 .10 .11 .12 .13 .14 .15 .16 .17
.01 .11 .26 .47 .68 .89 .89
1.11
1.11
1.11
1.26
1.47
1.68
1.89
1.89
2.11
2.11
2.11
T Q
M1
M2
Tax
Minimum
breakpoint
.00 .01 .02 .03 .04 .06 .09 .10 .11 .12 .14 .17
.01 .11 .26 .47 .68 .89
1.11
1.26
1.47
1.68
1.89
2.11
Breakpoint
difference (¢)
1 10 (0.11-0.01) 15 (0.26-0.11) 21 (0.47-0.26) 21 (0.68-0.47) 21 (0.89-0.68) 0 (0.89-0.89) 22 (1.11-0.89) 0 (1.11-1.11) 0 (1.11-1.11) 15 (1.26-1.11) 21 (1.47-1.26) 21 (1.68-1.47) 21 (1.89-1.68) 0 (1.89-1.89) 22 (2.11-1.89) 0 (2.11-2.11) 0 (2.11-2.11)
B: Non-cyclic
C: Cyclic-1
D: Cyclic-2

Job-Code-Based Programming

This section illustrates how to program items using job codes. Using job codes allows you to program a wide variety of items in comparison with direct programming.
Start this programming by entering a corresponding job code as shown below.
All the items which can be programmed by the job-code-based programming are listed on this page and the following, and those which can also be programmed by the direct programming are marked with the symbol “ ” that follows job codes.

Setting the date

Enter the month (one or two digits), day (two digits), and year (four digits: 2000 – 2099) in this sequence.

Setting the time

Set the time using the military time (24-hour) system. For example, when the time is set to 2:30 AM, enter 230; and when it is set to 2:30 PM, enter 1430. The time is printed and displayed on the real time system.
Time
2611
.@
1430
Ç
PrintKey operation
Example
2611
.
@
Ç
Time (max. four digits)
Procedure
Direct2611
PGM 2
2610
.@
08262004
Ç
PrintKey operation
Example
2610
.
@
Ç
Date (seven or eight digits)
Procedure
Direct2610
PGM 2

Setting the date and time

1
Direct
96
2110
.
@
Date
97

Setting the register number

When your store has two or more registers, it is practical to set separate register numbers for their identification. You may set them with a maximum of six digits.
To set the register number as “123456”

Setting the consecutive number

The consecutive number is increased by one each time a receipt is issued. Enter a number (one to four digits) that is one less than the desired starting number.
Setting the count start number as “1001”
Consecutive number
2613
.@
1000
Ç
PrintKey operation
Example
.
@
2613
Ç
A number (one to four digits) that is one
less than the desired starting number
To begin the count from 0001
Procedure
2613
PGM 2
2612
.@
123456
Ç
PrintKey operation
Example
2612
.
@
Ç
Register number
(one to six digits)
To set the register number “0”
Procedure
2612
PGM 2

Setting the register and consecutive numbers

2
Register number
98
Your machine has an automatic tax calculation feature which allows you to program four tax tables or rates to avoid calculating incorrect tax amounts. Automatic tax calculations require you to program, in addition to the tax table and rate, the tax status of each pertinent department, PLU/UPC, and function key.

The tax table (applicable to the add-on tax)

Sample tax table
New Jersey tax table: 6%
To program a tax table, first make a table like the right table shown above. From the tax table, calculate the differences between a minimum break point and the next one (A). Then, from the differences, find irregular cycles (B) and regular cycles (C and D). These cycles will show you the following items necessary to program the tax table:
T: The tax amount collected on the minimum taxable amount (Q) Q: The minimum taxable amount M1: The maximum value of the minimum breakpoint on a regular cycle (C).
We call this point “MAX point.”
M2: The maximum value of the minimum breakpoint on a regular cycle (D).
We call this point “MAX point.”
M: Range of the minimum breakpoint on a regular cycle: difference between Q and M1 or between M1 and
M2
Taxes
Range of sales amount
Minimum breakpoint
.00 .01 .02 .03 .04 .05 .06 .07 .08 .09 .10 .11 .12 .13
.01 .11 .23 .39 .57 .73 .89
1.11
1.23
1.39
1.57
1.73
1.89
2.11
Maximum breakpoint
.10 .22 .38 .56 .72 .88
1.10
1.22
1.38
1.56
1.72
1.88
2.10
2.22
to to to to to to to to to to to to to to
T Q
M1
M2
A: Difference between the minimum breakpoint and the next one (¢)
– 10 (0.11 - 0.01) 12 (0.23 - 0.11) 16 (0.39 - 0.23) 18 (0.57 - 0.39) 16 (0.73 - 0.57) 16 (0.89 - 0.73) 22 (1.11 - 0.89) 12 (1.23 - 1.11) 16 (1.39 - 1.23) 18 (1.57 - 1.39) 16 (1.73 - 1.57) 16 (1.89 - 1.73) 22 (2.11 - 1.89)
B: Non-cyclic
C: Cyclic-1
D: Cyclic-2
Direct2710
PGM 2

Programming for the automatic tax calculation function

3
Loading...