SHARP 530UIB Service Manual

ELECTRONIC CASH REGISTER
INSTRUCTION MANUAL
MODEL
ER-A520 ER-A530
The above illustration shows the model ER-A520.
FCC Regulations state that any unauthorized changes or modifications to this equipment not expressly approved by the manufacturer could void the user's authority to operate this equipment. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harm­ful interference when the equipment is operated in a commercial environ­ment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
WARNING
CAUTION
The AC outlet shall be installed near the equipment and shall be easily accessible.
Please record below the model number and serial number, for easy reference, in case of loss or theft. These numbers are located on the right side of the unit. Space is provided for further pertinent data.
Model Number
Serial Number
Date of Purchase
Place of Purchase
FOR YOUR RECORDS

INTRODUCTION

Thank you very much for your purchase of the SHARP Electronic Cash Register, Model ER-A520/A530. Please read this manual carefully before operating your machine to gain a thorough understanding of the functions and features offered by this model ECR. Please keep this manual for future reference, it may help you if you encounter operational problems.

IMPORTANT

Install your register in a location that is not subject to direct radiation, unusual temperature changes,
high humidity or exposed to water sources.
Installation in such locations could cause damage to the cabinet and the electrical components.
The register should not be operated by an individual with wet hands. The water could seep into the interior of the register and cause component failure.
When cleaning your register, use a dry, soft cloth. Never use solvents, such as benzine and/or thinner. The use of such chemicals will lead to discoloration or deterioration of the cabinet.
The register plugs into any standard wall outlet (120V ±10% AC) which utilizes a dedicated ground
circuit.
Please note that other electrical devices on the same electrical circuit could cause the register to malfunction.
• If the register malfunctions, call your local dealer for service - do not try to repair the register yourself.
• For a complete electrical disconnection, the AC power cord must be removed from the wall outlet.
• Never disconnect the peripheral while the register remains plugged into the AC outlet.

PRECAUTION

This Electronic Cash Register has a built-in memory protection circuit which is supported by rechargeable batteries. It is important to know that all batteries will, in time, dissipate their charge even if not used. Therefore to insure an adequate charge in the protection circuit, and to prevent any possible loss of memory during or after installation, it is recommended that each unit be allowed to recharge for a period of 24 to 48 hours prior to and during use by the customer. In order to charge the batteries, the machine must be plugged in. This recharging precaution can prevent unnecessary equipment malfunctions or service calls.
1

CONTENTS

INTRODUCTION····················································································································································1 IMPORTANT··························································································································································1 PRECAUTION························································································································································1 CONTENTS····························································································································································2
EXTERNAL VIEW OF THE ER-A520····················································································································8
Front view···············································································································································8 Rear view················································································································································8
EXTERNAL VIEW OF THE ER-A530····················································································································9
Front view···············································································································································9 Rear view················································································································································9
PRINTER······························································································································································10 KEYBOARD·························································································································································11
1 ER-A520 standard keyboard layout·········································································································11 2 ER-A530 standard keyboard layout·········································································································13 3 Standard key number layout····················································································································15 4 Installing the keyboard sheet (ER-A530)·································································································16
KEYS AND SWITCHES·······································································································································17
1 Mode switch and mode keys ···················································································································17 2 Drawer lock key·······································································································································17 3 Printer cover lock key ······························································································································18 4 Cashier/Server code entry key ················································································································18 5 Receipt ON/OFF function ························································································································18
DISPLAYS ···························································································································································19
1 Operator display ······································································································································19 2 Customer display (Pop-up type)··············································································································19
PRIOR TO ENTRIES ···········································································································································20
1 Preparations for entries ···························································································································20 2 Power save mode····································································································································21 3 Error warning···········································································································································21
ENTRIES······························································································································································22
1 Item entries··············································································································································22
Single item entries································································································································22 Repeat entries ······································································································································23 Multiplication entries·····························································································································24 Successive multiplication entries··········································································································25 Split-pricing entries·······························································································································26 Single item cash sale (SICS)/single item finalize (SIF) entries·····························································27 Scale entries·········································································································································28 PLU level shift (for direct PLU) ·············································································································30 PLU/UPC price level shift ·····················································································································32 Set PLU entries ····································································································································33 Link PLU/UPC entries···························································································································34 Age verification (Birthday entry) ···········································································································34 Mix-and-match entries··························································································································35 Condiment entries (for PLUs)···············································································································35 Price inquiry (view) function (for PLU/UPCs)························································································36 UPC learning function···························································································································37 Price change function (for PLU/UPCs)·································································································38
2 Displaying and printing subtotals·············································································································40
Merchandise subtotal ···························································································································40
FOR THE OPERATOR
2
Taxable subtotal ···································································································································40 Including-tax subtotal (full subtotal)······································································································40 Food stamp-eligible subtotal·················································································································40 Tray subtotal·········································································································································40 Eat-in subtotal·······································································································································40 Gasoline discount subtotal ···················································································································40
3 Finalization of transaction························································································································41
Cash or Check tendering······················································································································41 Mixed tendering (check + cash)············································································································41 Cash or Check sale that does not need any tender entry ····································································42 Charge (credit) sale······························································································································42 Mixed-tender sale (cash or check tendering + charge tendering) ························································42
4 Food stamp calculations··························································································································43
Food stamp tendering···························································································································43 Food stamp status shift ························································································································44
5 Tax calculations·······································································································································45
Automatic tax········································································································································45 Manual tax············································································································································45 Automatic-tax delete·····························································································································46 Tax status shift ·····································································································································47
6 Guest check (GLU/PBLU) ·······················································································································48
GLU/PBLU system ·······························································································································48 Deposit entries······································································································································51 Transferring guest checks out or in (Transfer-out/in) ···········································································52 Bill totalizing/bill transfer·······················································································································53 Bill separating·······································································································································54 Manual Previous Balance(PB) and Credit Balance(CB) entry······························································55
7 Auxiliary entries ·······································································································································57
Percent calculations (premium or discount) ·························································································57 Discount entries····································································································································58 Refund entries ······································································································································59 Return entries·······································································································································59 Refund sales mode·······························································································································60 Printing of non-add code numbers ·······································································································60 Gratuity·················································································································································61
8 Payment treatment ··································································································································62
Tip-in entries·········································································································································62 Tip editing·············································································································································63 Tip paid entries·····································································································································63 Currency conversion·····························································································································64 Received on account entries ················································································································65 Paid out entries·····································································································································65 No sale (exchange) ······························································································································65 Cashing a check···································································································································66 Bottle return··········································································································································66
9 Automatic sequencing key entries···········································································································66
10 WASTE mode··········································································································································67
CORRECTION ·····················································································································································68
1 Correction of the last entry (direct void)···································································································68 2 Correction of the next-to-last or earlier entries (indirect void)··································································68 3 Subtotal void············································································································································69 4 Correction of incorrect entries not handled by the direct or indirect void function···································69
CORRECTION AFTER FINALIZING A TRANSACTION (AFTER GENERATING A RECEIPT)························70 OVERRIDE ENTRIES··········································································································································71
OVERLAPPED CASHIER/SERVER ENTRY ······································································································72 SPECIAL PRINTING FUNCTIONS······················································································································73
1 Copy receipt printing································································································································73
3
2 Validation printing function (Slip printer)··································································································74 3 Bill printing···············································································································································74 4 Printing of the employee’s arrival and departure times (Slip printer)·······················································74 5 Printing of header and footer graphic logos·····························································································75 6 Remote printer send function ··················································································································75
TIME DISPLAY AND AUTOMATIC UPDATING OF THE DATE ········································································76
1 Time display ············································································································································76 2 Automatic updating of the date················································································································76
PRIOR TO PROGRAMMING·······························································································································77
1 Programming keyboard layout·················································································································77 2 How to program alphanumeric characters·······························································································78
Using character keys on the keyboard ·································································································78 Entering character codes······················································································································78
PROGRAMMING ·················································································································································80
Basic instructions··································································································································80 Preparations for programming··············································································································80
Direct Programming···········································································································································80
1 Setting the date and time·························································································································80
Date······················································································································································80 Time······················································································································································81
2 Programming for departments·················································································································81
Unit price ··············································································································································81 Functional selection······························································································································82
3 PLU/UPC programming···························································································································84
Unit price ··············································································································································84 Functional selection······························································································································85 Associated department·························································································································86
4 Programming for discount keys (
-
) ······································································································87 Discount amount ··································································································································87 Functional programming·······················································································································87
5 Programming for percent keys (
%
)········································································································88 Percent rate··········································································································································88 Functional programming·······················································································································89
6 Programming for conversion keys (
ç
) ··································································································90
Currency conversion rate ·····················································································································90
7 Programming for the
r, p
, and † keys ···························································································90
High amount lockout (HALO)················································································································90
8 Programming for the
a
, , ', and k keys···················································································91
High amount lockout (HALO) and function selection············································································91
9 Programming for the automatic tax calculation function··········································································93
The tax table (applicable to the add-on tax) ·························································································93
Job-Code-Based Programming ························································································································96
1 Setting the date and time·························································································································96
Setting the date (#2610)·······················································································································96 Setting the time (#2611) ·······················································································································96
2 Setting the register and consecutive numbers ························································································97
Setting the register number (#2612)·····································································································97 Setting the consecutive number (#2613)······························································································97
3 Programming for the automatic tax calculation function··········································································98
The tax table (#2710) ···························································································································98 The tax rate (#2711)···························································································································100 Doughnut tax exempt (for the Canadian tax system) (#2715)····························································101
4 Programming for departments···············································································································102
Functional programming 1 (#2110) ····································································································102
CA
FOR THE MANAGER
4
Functional programming 2 (#2111) ····································································································104 A limit amount (HALO) of entry (#2112) ·····························································································105 Item label (#2114)·······························································································································105 Unit price (#1110)·······························································································································106 Commission group assignment (#2115)·····························································································106 Group number (#2116)·······················································································································107 Group text (#2350) ·····························································································································107 Age limitation (#2180)·························································································································108 Print station assignment (#2118)········································································································108 Department key positioning (#2119)···································································································109 Color Video Monitor (CVM) control character (#2158) ·······································································109
5 PLU/UPC programming·························································································································110
Associated department (#1200, 2230, 1050) ·····················································································111 Unit prices (#1210, 1060) ···················································································································113 Base quantity (#1211, 1061) ··············································································································114 Functional programming 1 (#2210, 2231, 2060) ················································································114 Functional programming 2 (#2211, 2232, 2061) ················································································116 Item label (#2214, 2064)·····················································································································118 Commission groups (#2215, 2235, 2065) ··························································································119 Group number (#2216, 2066)·············································································································120 Group text (#2351) ·····························································································································120 Age limitation (#2280, 2236, 2081)·····································································································121 Stock quantity (#1222, 1220, 1221)····································································································122 Set PLU (#2221)·································································································································123 Mix-and-match table (#2217, 2225, 2067)··························································································124 PLU condiment table (#2222, #2223)·································································································125 Print station to PLU/UPC assignment (#2218, 2068) ·········································································127 Delete period for non-accessed UPC codes (#2029)·········································································128 Programming Non-PLU code format (#2025)·····················································································129 Link PLU/UPC link (#2220)·················································································································130 Programming of PLU levels and direct PLU keys (#2219) ·································································130 Item label for remote printer (#2244, 2094)························································································131 Color Video Monitor (CVM) control character (#2258, 2234, 2059) ···················································132
6 Programming for miscellaneous keys····································································································133
Rate (
%, ç
, commission, gratuity, , ) and discount (-) (#1310) ····································133 Gas discount unit price (#1311)··········································································································134 Currency description text (
ç
) (#2334)······························································································134
A limit amount (HALO) of entry (
-, †
(for manual tax), , , r, p) (#2312) ····················135
+/– sign, food stamp status and tax status (%, -, gratuity) (#2311)··············································136 Percent entry type (
%
) (#2310) ········································································································137
Item % or subtotal % selection (
%
) (#2315)·····················································································138
Percent rate limitation (
%
) (#2313)···································································································138
Vendor or store coupon selection (
-
) (#2316)·················································································139
7 Programming for the media keys···········································································································140
Functional programming 1 (#2320) ····································································································140 Functional programming 2 (#2326) ····································································································142 High amount lockout (HALO) for check cashing, check change, and cash in drawer (#2321)···········143 High amount lockout (HALO) of entry for media keys (#2322)···························································143 Print station assignment (#2328)········································································································144 CAT programming (#2330)·················································································································145
8 Programming of function text·················································································································146
Programming (#2314)·························································································································146 List of function texts····························································································································146
9 Server/Cashier programming ················································································································150
Server/Cashier code (#1400) ·············································································································150 Server/Cashier name (#1414) ············································································································150
CH TIPCATIP
CH TIPCATIP
5
Functional programming (#2410) ·······································································································151 GLU/PBLU code range assignment (#2411)······················································································151 Net sales % rate (#2413)····················································································································152
10 Programming various functions·············································································································152
Programming for optional feature selection (#2616) ··········································································152 Programming the parameter of the slip printer (#2615)······································································157 Setting the time limit for THE TILL TIMER
TM
(#2617) ·········································································158 Scale tare table (#2618) ·····················································································································158 Programming of logo messages (#2614) ···························································································159 Selection of X1/Z1 and X2/Z2 reports to be printed in the stacked report sequence (#2620)············160 Setting the time range for hourly reports (#2619)···············································································161 Programming of power save mode (#2689) ·······················································································161 Available GLU/PBLU codes (#2810) ··································································································162 Bill number (#2636) ····························································································································162 Functional programming for the printer (#2990)·················································································163 Editing guidance/error messages (#2641)··························································································163 Validation message (#2642)···············································································································165 Slip printer’s logo message (#2643)···································································································165 RS-232C channel assignment (#2690) ······························································································166 Barcode reader programming (#2691) ·······························································································167 Remote printer assignment (#2692)···································································································168 Second remote printer assignment (#3653) ·······················································································168 Remote printer name (#3654) ············································································································169 Print format for remote printer (#3655)·······························································································169 Chit receipt format (#3656)·················································································································170 RS-232C interface (#6110, 6111, 6112, 6113, 6115, 6212, 6213, 6220)···········································171 Programming the CAT interface (#7110, 7111, 7112, 7113, 7114, 7115, 7116)································173 Secret codes to control access to the PGM1 mode, X1/Z1 mode and X2/Z2 mode (#2630, 2631, 2632) ···························································································································175 Loading dynamic UPCs to the main UPC file (#2099)········································································175 Setting the AUTO key (#2900) ···········································································································176
11 TRAINING mode ···································································································································177 12 Reading stored programs······················································································································178
Program details and procedures for their reading ··············································································178 Sample printouts·································································································································180
13 Universal Product Code (UPC) or European Article Number (EAN) ·····················································188
UPC or EAN code·······························································································································188 Add-on code ·······································································································································189
READING (X) AND RESETTING (Z) OF SALES TOTALS···············································································190
1 Summary of reading (X) and resetting (Z) reports and the key operations to obtain the reports ··········190 2 Daily sales totals····································································································································195
General report ····································································································································195 Cashier/Server report ·························································································································199 Hourly report·······································································································································200 Full department report ·······················································································································201 Individual group total report on department························································································201 Full group total report on department ·································································································201 PLU/UPC report (by designated range or pick up list)········································································202 PLU/UPC report by associated department ·······················································································204 Individual group total report on PLU/UPC ··························································································204 Full group total report on PLU/UPC····································································································204 PLU/UPC zero sales report by department ························································································205 PLU/UPC price category report··········································································································205 PLU/UPC stock report (by designated range or pick up list) ······························································205 Commission sales report····················································································································205 GLU/PBLU report ·······························································································································206 GLU/PBLU report by cashier/server···································································································206
6
Closed GLU/PBLU report ···················································································································207 Closed GLU/PBLU report by cashier/server·······················································································208 Transaction report ······························································································································209 Tax report ···········································································································································209 Cash in drawer report·························································································································209 Dynamic UPC report (by designated range or pick up list)·································································210 Dynamic UPC report by associated department ················································································210 Dynamic UPC clear (by designated range or pick up list) ··································································210 Dynamic UPC clear by associated department··················································································210 X1/Z1 stacked report ··························································································································210 Deleting of non-accessed UPCs·········································································································211
3 Periodic consolidation····························································································································212
General Overview·······························································································································212 Daily net report ···································································································································212 X2/Z2 stacked report ··························································································································212
COMPULSORY CASH/CHECK DECLARATION······························································································213 OPERATOR MAINTENANCE ···························································································································215
1 In case of power failure ·························································································································215 2 In case of printer error ···························································································································215 3 Thermal printing·····································································································································215
Cautions in handling the printer··········································································································215 Cautions in handling the recording paper (thermal paper) ·································································216
4 Installing and removing the paper roll····································································································217
Recording paper specifications ··········································································································217 Installing the paper roll ·······················································································································217 Removing the paper roll ·····················································································································218
Removing a paper jam ·······················································································································220 5 Cleaning the print head ·························································································································221 6 Removing the till and the drawer···········································································································222 7 Opening the drawer by hand ·················································································································222 8 Before calling for service ·······················································································································223
Error message table ···························································································································223
LIST OF OPTIONS ············································································································································224 SPECIFICATIONS ·············································································································································225
7

EXTERNAL VIEW OF THE ER-A520

Front view

Rear view

8
Printer cover
Receipt paper
Journal window
Keyboard
Drawer
Drawer lock
Customer display (Pop-up type)
Operator display
Mode switch
Printer cover lock
(left side)
Rear cover
9

EXTERNAL VIEW OF THE ER-A530

Front view

Rear view

Printer cover
Receipt paper
Journal window
Keyboard
Drawer
Drawer lock
Customer display (Pop-up type)
Operator display
Mode switch
Printer cover lock
(left side)
Rear cover
10

PRINTER

The printer is a receipt/journal dual station type thermal printer which delivers fast, quiet and high quality printing. The average life of the printer is approximately 5 million lines.
When opening the printer cover, unlock the printer cover using the printer cover lock key, and lift up the cover as shown in the diagram to the right.
Your register is shipped with the print head release lever held in the up position by a white shipping retainer. Be sure to remove this retainer (see the figure at the right) and push down the print head release lever before you use the register.
Print head release lever
The print head can be lifted by the green lever on the right side of the printer. Pulling the lever forward, lifts the print head up. If the paper becomes jammed and you need to move the print head farther forward, you can pull the lever even further toward you and proceed with the removal of the jammed paper.
Do not attempt to remove the paper roll with the head in the down position. This may result in
damage to the printer and print head.
Note
Retainer
Printer lock keyPrinter cover
Paper roll location
Take-up spool
Paper chute
Print head release lever
11

KEYBOARD

All keys except the receipt paper feed and journal paper feed keys can be re-positioned. If you want to change the layout, please consult your authorized SHARP dealer.
0
9
RFND
VOID
00
CL
Numeric keys
Decimal point key
Clear key
Multiplication key
Refund key
Void key
Amount entry key
Cashier code entry key
PLU/UPC
AMT
CASH
#
RECEIPT
JOURNAL
Receipt paper feed key
Journal paper feed key
PLU/UPC key
INQ
PLU/UPC inquiry key
UPC price change key
PRICE CHANGE
201
Department keys
Automatic sequencing 1 and 2 keys
AUTO
1
AUTO
2
FS
SHIFT
Food stamp shift key
No-sale key
NS
TAX 1 shift key
TAX
Manual tax key
Merchandise subtotal key
RA
Received-on-account 1 key
PO
Paid-out 1 key
FOR
@
Previous balance key
PBLU
Final key
FINAL
New check key
NC
Discount 1 key
%1 %2
Percent 1 and 2 keys
TAX
SHIFT
MDSE
SBTL
Note
L
.
RCPT
NC AMT
5
INQ
AUTO
1
FS
SHIFT
PBLU
7 4 1
0
00
4
3
2
1
10
9
8
7
6
15
14
13
12
11
20
19
18
17
16
FS
TEND
CA/AT
CH1
CH2CHK
MDSE
SBTL
SBTL
AUTO
2
2
5 6
8 9
TAX
SHIFT
RFND
%2
#/TM
VOID
PLU/UPC
3
SLIP
RA
FINALCONV
PO TAX%1
CASH
#
@
FOR
PRICE
CHANGE
NS

ER-A520 standard keyboard layout

1
12
The following function keys can optionally be mounted in place of those shown in the figure of the
standard keyboard layout. For details, please consult your authorized SHARP dealer.
Optional keys
%3 %5
Percent 3 thru 5 keys Eat in 1 thru 3 keys
CONV2 CONV4
RA2
Received-on-account 2 key
PO2
Paid-out 2 key
SRVC
Service key
RETURN
Return key
Tray subtotal key
AUTO
3
TRAY SBTL
Transfer out key
TRANS
OUT
Transfer in key
TRANS
IN
Cash tip key
CA TIP
Charge tip key
CH TIP
AUTO
10
Automatic sequencing 3 thru 10 keys
Cash 2 thru 5 keys
Currency conversion 2 thru 4 keys
CA2 CA5
CH3 CH9
Charge 3 thru 9 keys
-
2
-
Discount 2 thru 5 keys
5
DEPT
#
Dept. number key
REPEAT
Repeat entry key
SCALE
L1
Scale entry key
PRINT
Validation print key
PLU level shift 1 thru 5 keys
Gasoline sales subtotal key
TIP
PAID
Tip paid key
DEPO
Deposit key
LEVEL
#
PLU level shift number key
RP
SEND
Remote printer send key
DEPO
RFND
Deposit refund key
GRT
EXEMPT
Gratuity exempt key
OPEN
TARE
Tare entry key
CHK2 CHK5
Check 2 through 5 keys
EAT IN1EAT IN
3
Tax 2 thru 4 shift keys
TAX2
SHIFT
TAX4
SHIFT
GAS
SBTL
Price shift number key
P-SHIFT
#
Cover count entry key
CV
CNT
L5
P1
Price level shift 1 thru 6 keys
P6
Note
#/TM
Non-add code/Date & time display key
Receipt print key
RCPT
Slip printer key
SLIP
Food stamp tender key
FS
TEND
CH1CH
2
Charge 1and 2 keys
CONV
Currency conversion key
CHK
Check 1 key
SBTL
Subtotal key
CA/AT
Cash/amount tendered key
13
The department and direct PLU keys may be expanded. If you require expansion of the department
or direct PLU keys, please contact your dealer.
All keys except the receipt paper feed and journal paper feed keys may be re-positioned. If you want to change the keyboard layout, please consult your dealer.
Please note that the price lookup/subdepartment/UPC key (
P
) and the previous balance key
() are shown as and
u
respectively in this manual.
0
9
RFND
RCPT
VOID
00
000
CL
Numeric keys
Decimal point key
Clear key
Multiplication key
Receipt print key
Refund key
Void key
PLU/
SUB
RECEIPT
JOURNAL
Receipt paper feed key
Journal paper feed key
Direct price lookup keys
FOR
@
Price lookup/subdepartment/ UPC key
1 100
PLU/ UPC
PBAL
Note
31
20
9
79
67
56
45
34
23
12
1
32
21
10
80
68
57
46
35
24
13
2
33
22
11
91
81
69
58
47
36
25
14
3
64
53
42
92
82
70
59
48
37
26
15
4
65
54
43
93
83
71
60
49
38
27
16
5
66
55
44
99
89
77
100
90
78
94
84
72
61
50
39
28
17
6
97
87
75
95
85
73
62
51
40
29
18
7
98
88
76
96
86
74
63
52
41
30
19
8
CONV
RP
SEND
%RCPT
L1 L2 L3
SBTL
CA/AT
PBAL
SRVC
CH1
CH2
CH3FINAL
NCRFND
CHK
AUTO
1
AUTO
2
SERV
#
AUTO
3
MDSE
SBTL
000
000
123
456
789
CL
RECEIPT
JOURNAL
@
FOR
PLU/ SUB
INQVOID

ER-A530 standard keyboard layout

2
Note
BS
Bill separation key
BIRTH
Birthday entry key
BT
Bill totalize/Bill transfer key (CHECK-ADD)
WASTE
Condiment next key
000
Numeric key
RFND
SALES
C
NEXT
Condiment cancel key
C
CANCEL
Edit tip key
EDIT
TIP
Table# recall key
GLU
RECALL
Refund sales key
Waste mode key
No delete key
NO DEL
14
The following function keys can optionally be added in place of those shown in the figure of the
standard keyboard layout. For details, please consult your authorized SHARP dealer.
Optional keys
%2 %5
Percent 2 thru 5 keys
Eat in 1 thru 3 keys
CONV2 CONV4
RA1
Received-on-account 1 and 2 keys
PO1
RA2
PO2
Paid-out 1 and 2 keys
AUTO
4
Transfer out key
TRANS
OUT
Transfer in key
TRANS
IN
Cash tip key
CA TIP
AUTO
10
Automatic sequencing 4 thru 10 keys
Cash 2 thru 5 keys
Currency conversion 2 thru 4 keys
CA2 CA5
CH4 CH9
Charge 4 thru 9 keys
-
2
-
Discount 2 thru 5 keys
5
DEPT
#
Dept. number key
SCALE
Scale entry key
Gasoline sales subtotal key
TIP
PAID
Tip paid key
DEPO
Deposit key
DEPO
RFND
Deposit refund key
CHK2 CHK5
Check 2 through 5 keys
EAT IN1EAT IN
3
Tax 1 thru 4 shift keys
TAX1
SHIFT
TAX4
SHIFT
GAS
SBTL
TAX
Manual tax key
NS
No-sale key
Tray subtotal key
TRAY
SBTL
RETURN
Return key
#/TM
Non-add code/Date & time display key
Charge tip key
CH TIP
Note
CHK
Automatic sequencing 1 thru 3 keys
Currency conversion key
Charge 1 thru 3 keys
CONV
Check 1 key
CA/AT
SBTL
Cash/amount tendered key
Server code entry key
PLU/UPC inquiry key
INQ
Discount 1 key
%
Percent 1 key
SERV
#
Previous balance key
PBAL
Service key
SRVC
Final key
FINAL
AUTO1AUTO
3
CH
1
CH
3
Merchandise subtotal key
MDSE
SBTL
Subtotal key
RP
SEND
Remote printer send key
NC
L1 L3
New check key
PLU level shift 1 thru 3 keys
15
Department and direct PLU keys can be expanded. If you require expansion of the department or
direct PLU keys, please contact your authorized SHARP dealer.
Note
Condiment next key
C
NEXT
Condiment cancel key
C
CANCEL
Edit tip key
EDIT
TIP
Table# recall key
GLU
RECALL
Food stamp shift key
FS
SHIFT
Food stamp tender key
FS
TEND
BIRTH
Birthday entry key
WASTE
RFND
SALES
Refund sales key
Waste mode key
UPC price change key
PRICE CHANGE
PRINT
Validation print key
GRT
EXEMPT
Gratuity exempt key
Price shift number key
P-SHIFT
#
Cover count entry key
CV
CNT
P1
Price level shift 1 thru 6 keys
P6
LEVEL
#
PLU level shift number key
L4
PLU level shift 4 and 5 keys
L5
BS
Bill separation key
BT
Bill totalize/Bill transfer key (CHECK-ADD)
Slip printer key
SLIP
No delete key
NO DEL
REPEAT
Repeat entry key
AMT
Amount entry key
OPEN TARE
Tare entry key
These key numbers are used for positioning of department keys and direct PLU keys. For further details with positioning departments and PLU keys, please refer to pages 109 and 130. This layout can be changed by your dealer.
001
006
011
016
002
007
012
017
003
008
013
018
004
009
014
019
005
010
015
020

Standard key number layout

3
For ER-A520
16
Insert the keyboard sheet between the keyboard cover and the cabinet as illustrated below. Then press the claws at the top of the keyboard cover into the slots in the cabinet.
Do not spread the keyboard cover too far to avoid tearing the tabs.
Replace the keyboard sheet with a new one if by chance it gets wet. Use of a wet keyboard
sheet may cause problems.
Be sure to use only SHARP-supplied keyboard sheets. Thick or hard sheets can make key operations difficult.
Place the keyboard sheet evenly under the keyboard cover.
If you require a new keyboard sheet, please contact your dealer.
The keyboard cover will eventually wear out. If your keyboard cover is dirty or broken, replace the
cover with a new one. For details, please contact your authorized SHARP dealer.
Note
Keyboard sheet
Cabinet
Keyboard cover

Installing the keyboard sheet (ER-A530)

4
028
029
030
031
021
022
023
024
025
026
027
039
040
041
042
032
033
034
035
036
037
038
050
051
052
053
043
044
045
046
047
048
049
061
062
063
064
054
055
056
057
058
059
060
072
073
074
075
065
066
067
068
069
070
071
083
084
085
086
076
077
087
088
099
100
078
079
080
081
082
096
097
098
089
090
091
092
093
094
095
108
109
110
101
102
103
104
105
106
107
118
119
120
111
112
113
114
115
116
117
For ER-A530
17

KEYS AND SWITCHES

The mode switch can be operated by inserting one of the three supplied mode keys – manager (MA), submanager (SM), and operator (OP) keys. These keys can be inserted or removed only when the switch is in the “REG” or “OFF” position.
The mode switch has these settings:
OFF: This mode locks all register operation.
No change occurs to register data.
OP X/Z: This setting allows cashiers to take X or Z reports for their sales
information. It can also be used for displaying the date/time and printing the employee’s arrival/departure times. And it can be used to toggle receipt state “ON” and “OFF” by pressing the
q
key. (This setting may be used only when your register has been
programmed for “OP X/Z mode available” in the PGM2 mode.)
REG: For entering sales PGM1: To program those items that need to be changed often: e.g., unit prices of departments, PLUs or
UPCs, and percentages.
PGM2: To program all PGM1 programs and those items that do not require frequent changes: e.g., date,
time, or a variety of register functions.
MGR: For manager’s and submanager’s entries
The manager can use this mode to make entries that are not permitted to be made by cashiers – for example, after-transaction voiding and override entries.
X1/Z1: To take the X/Z report for various daily totals. X2/Z2: To take the X/Z report for various periodic (weekly or monthly) consolidation of totals.
This key locks and unlocks the drawer. To lock it, turn 90 degrees counterclockwise. To unlock it, turn 90 degrees clockwise.
SK1-1

Drawer lock key

2
Operative range

Mode switch and mode keys

1
MA
SM OP
• Manager key (MA)
• Submanager key (SM)
• Operator key (OP)
18
This key locks and unlocks the printer cover. To lock it, turn 90 degrees counterclockwise. To unlock, turn 90 degrees clockwise.
The ER-A520 provides a cashier system and the ER-A530 provides a server system. The cashier/server codes are available in two variants: Variant 1, the codes are displayed (“0000” to “9999”), and Variant 2, the codes are not displayed (always “ ”). When the cashier/server code is assigned by Variant 2 (codes not displayed), the register prints as the cashier/server code and the cashier/server name are printed both on the receipt and journal for every transaction.
All settings depend on how the register has been programmed. For the available selection of these settings, please consult your authorized SHARP dealer.
You can disable receipt printing in the REG mode to save paper using the receipt function. To disable receipt printing, press the
q
key in the OP X/Z position. This key toggles the receipt printing status ON and OFF. To
check the receipt printing status, turn the mode switch to the OP X/Z position or press the
c
key in the REG
mode. When the function is in the OFF status, the receipt off indicator “_” illuminates.
Your register will print reports regardless of the receipt status. This means that the receipt roll must be installed even when the receipt state is
OFF” when taking reports.
Note

Receipt ON/OFF function

5
Note
‹‹
Cashier/server
code
To display the current cashier/server code
Sign-on
Variant 1 : (Code is displayed.)
Variant 2 : (Code is not displayed.)
Sign-off Variant 1 / Variant 2 :
SERV
/
Cashier/server
code
‹‹
SERV
/
‹‹
SERV
/
‹‹
SERV
/
‹‹
SERV
/
Procedure

Cashier/Server code entry key

4

Printer cover lock key

3
19

DISPLAYS

The operator display consists of a two-line dot-matrix display (16 characters/line).
• Cashier/server code or mode name
The mode you are in is displayed. When a cashier/server is assigned, the cashier/server code is displayed in the REG or OP X/Z mode. For example, “0001” is displayed when cashier/server 0001 is assigned.
• Repeat
The number of repeats is displayed, starting at “2” and increments with each repeat. When you have
registered an item ten times, the display will show “0”. (2 3 ......9 0 1 2...)
• Sentinel mark
When amounts in the drawer reaches the amount you preprogrammed, the sentinel mark “X” is displayed to advice you to remove the money to a safe place.
• Power save mark
When the cash register goes into the power save mode, the power save mark (decimal point) is displayed.
• Stock alarm indicator
When the stock counter of the PLU or UPC which you entered is zero or negative, the alarm indicator (decimal point) is displayed.
• Function message display area
Item labels of departments and PLU/subdepartments/UPC and function text you use, such as %1, (–) and CASH are displayed here. For the details of function texts, please refer to pages 146 to 149. When an amount is to be entered or entered, “AMOUNT” is displayed: When an amount is to be entered, – – – – – – – is displayed in the numeric entry display area with “AMOUNT”. When a preset price has been set, the price is displayed in the numeric entry display area with “AMOUNT”.
• Numeric entry display area
Numbers entered using numeric keys are displayed here.
Date and time display
Date and time appear on the display in the OP X/Z, REG, or MGR mode. In the REG or MGR mode, press the key to display the date and time.
Error messages
When an error occurs, the corresponding error message is displayed in the function message display area. For the details of error messages, please refer to the “Error message table” on page 223.

Customer display (Pop-up type)

2
#/
TM
Function message display area
Cashier/server code or mode name
Numeric entry display area
Receipt OFF indicator (“_”)
/
Stock alarm indicator (“•”)
Repeat / Sentinel mark / Power save mark
Dept. name / PLU or UPC name / function text
Price level / PLU level (e.g. P2L3)

Operator display

1
20

PRIOR TO ENTRIES

Before registrations, insert the operator key into the mode switch and turn it to the REG position and check the following items:

Receipt and journal paper rolls

If the receipt and journal paper rolls are not set in the machine or there are low rolls, install new ones according to section “4. Installing and removing the paper rolls” under “OPERATOR MAINTENANCE.”

Receipt ON/OFF function

You can disable receipt printing in the REG mode to save paper using the receipt function. To disable receipt printing, press the
q
key in the OP X/Z position. This key toggles the receipt printing status ON and OFF.
To check the receipt printing status, turn the mode switch to the OP X/Z position or press the
c
key in the REG
mode. When the function is in the OFF status, the receipt off indicator “_” illuminates.
Your register will print reports regardless of the receipt state. This means that the receipt roll must be installed even when the receipt state is “OFF” when taking reports.

Cashier/Server assignment

The ER-A520 requires a cashier to be assigned prior to operational item entries. The ER-A530 enforces that a server must enter their code into the register. Depending on register settings, it is possible to keep the same cashier/server code assigned when the same cashier/server is to be used for all transactions within a set period. As previously mentioned, there are two variants to consider for the display and print of the cashier/server codes.
The operation entries depend on how the register has been programmed. To determine which selections should be considered, please consult your local dealer.
Note

Preparations for entries

1
FOR THE OPERATOR
Note
Logo message or graphic logo (varies depending on programming.)
Cashier/Server code
(“ ” is printed in Variant 2.)
Cashier/Server name
21
• If you want to enter a cashier/server code before every transaction, please consult your authorized SHARP dealer.
• For the display type selection of the cashier/server code, “Variant 1” has been preset. For the selection of the “Variant 2”, consult your authorized SHARP dealer.
• The cashier/server can be changed during a transaction. Please consult your authorized SHARP dealer.
The register will enter into the power save mode when no entries are performed based on the pre-programmed time limit (by default, 30 minutes). When the register goes to the power save mode, the operator and customer displays will turn off. This is indicated by a decimal point at the left most position of the lower line. The register will return to normal operation mode when any key is pressed or a mode is changed with the mode key. Please note when the register is recovered by any key entry the initial key entry is ignored. After the recovery, you may start the key entries from the beginning.
In the following examples, your register will go into an error state accompanied with a warning beep and a corresponding error message. Clear the error state by pressing the
c
key and take proper action.
Please refer to the error message table on page 223.
• When you enter an over 32-digit number (entry limit overflow): Cancel the entry and re-enter a valid number.
• When you make an error in key operation: Clear the error and continue entries.
• When you make an entry beyond a programmed amount entry limit: Check to see if the entered amount is correct. If it is correct, it be possible to make the entry in the MGR mode. Contact your manager.
• When an including-tax subtotal exceeds eight digits: Clear the subtotal by pressing the
c
key and press the
a, Å
thru É, k, thru , or hthru key to finalize the transaction.
CH9
CHK5
CHK2

Error warning

3

Power save mode

2
Note
‹‹
Cashier/server
code
To display the current cashier/server code
Sign-on
Variant 1 : (Code is displayed.)
Variant 2 : (Code is not displayed.)
Sign-off Variant 1 / Variant 2 :
SERV
/
Cashier/server
code
‹‹
SERV
/
‹‹
SERV
/
‹‹
SERV
/
‹‹
SERV
/
Procedure
22

ENTRIES

The example entries provided within this manual describe the function key labeled which is used for the model ER-A520. For the model ER-A530, please substitute the key with the
P
function key.

Single item entries

Department entries (direct department entries)
Enter a unit price and press a department key. If you use a programmed unit price, press a department key only.
*Less than the programmed upper limit amounts
When those departments for which the unit price has been programmed as zero (0) are entered, only the sales quantity is added.
Department entries (indirect department entries)
*Less than the programmed upper limit
amounts
PLU entries (indirect PLU entries)
Enter a PLU code and press the key.
When those PLU’s for which the unit price has been programmed as zero (0) are entered, only the sales quantity is added.
Subdepartment (open PLU, open and preset PLU) entries
*Less than the programmed upper limit
amounts
PLU entries (direct PLU entries)
Direct PLU key
Unit price *
(for subdept.)
When using a programmed unit price
PLU code
Unit price *
(max. 7 digits)
When using a programmed unit price
or
å
PLU/ UPC
PLU/
UPC
Note
PLU code
PLU/ UPC
PLU/ UPC
à
Unit price *
(max. 7 digits)
When using a programmed unit price
Dept. code
(1–99)
à
When [preset only dept.] is entered.
or
å
Note
Department keyUnit price *
(max. 7 digits)
When using a programmed unit price
Procedure

Item entries

1
PLU/ UPC
PLU/ UPC
Note
23

Repeat entries

You can use this function for entering a sale of two or more same items. You can use the
è
key to repeat entry instead of department, å, direct PLU or key.
200
8 8 8
5 à680
à à
10
P P P
ó ó
60
P
500
P P
5012345678900
P P
600
2 è è a
PrintKey operation
Example
PLU/ UPC
1200
3 5
8
à
5 à680
à
2
P
11 P1200
P
ô
5012345678900
P
a
PrintKey operation
Example
Repeated department entry (direct)
Repeated department entry (indirect)
Repeated PLU entry (indirect)
Repeated PLU entry (direct)
Repeated subdepartment entry
Repeated UPC entry
Repeated department entry (direct) using the repeat key
Ä
Scan UPC code
UPC code
(max.13 digits)
å
Unit price
(max. 6 digits)
To set “auto-delete”
PLU/
UPC
(Registration)
NON
DELETE
To cancel the learing function entry
DEPT
#
Dept. no.
(1 - 99)
(
1
~ )
When the dept. key is depressed directly
c
99
UPC entries
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/
UPC
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/ UPC
24

Multiplication entries

Use this feature when you need to enter two or more same items. This feature helps when you sell a large quantity of items or need to enter quantities that contain decimals.
• After scanning a UPC code or pressing the key, when the item does not exist in the file, the display will show “NO RECORD”. Enter the unit price using the
å
key and department no. with the àkey.
• Q’ty: Up to four digits integer + three digits decimal
• Unit price: Less than a programmed upper limit
• Q’ty × unit price: Up to seven digits
You must use a decimal point (.) key when entering quantities that are fractional.
Note
7 .500
@
165
8
2
@
5
à
250
à
15
@
13
P
8 .250
@ ò
3
@
60
P
100
P
5
@
5012345678900
P
a
PrintKey operation
Example
@
Unit price
PLU code
à
Unit price Direct PLU key
Q’ty Department key
When using a programmed unit price
Dept. entry (direct)
Dept. code Dept. entry (indirect)
PLU entry (indirect)
PLU/subdept. entry (indirect)
PLU/subdept. entry (direct)
Unit price
When [preset only dept.] is entered.
PLU code
Unit price
or
å
PLU/ UPC
à
or
å
PLU/ UPC
PLU/ UPC
Ä
Scan UPC code
UPC code
UPC entry
PLU/ UPC
Procedure
Department entry (direct)
Department entry (indirect)
PLU entry (indirect)
PLU entry (direct)
Subdepartment entry
UPC entry
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/ UPC
25

Successive multiplication entries

This function may be desired when you enter a sale of items sold by area (square feet).
• After scanning a UPC code or pressing the key, when the item does not exist in the file, the display will show “NO RECORD”. Enter the unit price using the
å
key and department no. with the àkey.
• Length or width: Up to seven digits (4-digit integer + 3-digit decimal)
• Unit price: Less than a programmed upper limit
• Length × Width × Unit price: Up to seven digits
For actual use of this function, please consult your dealer.
You must use a decimal point (
.
) key when entering quantities that are fractional.
3
@
4
@
400
5
1 .500
@
2 .500
@
8
P
1 .750
@
1 .750
@
6
P
600
P
4
@
5
@
5099887654302
P
a
PrintKey operation
Example
Note
Procedure
Department entry
PLU entry
Subdepartment entry
UPC entry
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/ UPC
When using a programmed unit price
Length Unit price
@@
Dept. entry (direct)Width Department key
Dept. code Dept. entry (indirect)
PLU code
PLU code
Unit price Direct PLU key
à
PLU/ UPC
PLU/ UPC
Ä
UPC code
PLU/ UPC
Unit price
When [preset only dept.] is entered.
Unit price
Scan UPC code
à
PLU/ UPC
or
or
å
å
PLU entry (indirect)
PLU/subdept. entry (indirect)
PLU/subdept. entry (direct)
UPC entry
26

Split-pricing entries

You may use this function when your customer wants to purchase items normally sold in bulk.
• After scanning a UPC code or pressing the key, when the item does not exist in the file, the display will show “NO RECORD”. Enter the unit price using the
å
key and department no. with the àkey.
• Selling quantity: Up to four digits integer + three digits decimal
• Base quantity: Up to two digits (integer)
You must use the decimal point (
.
) key when entering selling quantities that are fractional.
Note
7
@
10
@
600
7
8
@
5
@
35
P
5
@
6
@
5045678912304
P
a
PrintKey operation
Example
Procedure
Department entry
PLU entry
UPC entry
@
Unit price
per base q’ty
PLU code
Base q’ty
@
Selling q’ty
When using a programmed unit price
Only when you use a base q’ty programmed for PLU code
Department key
à
Dept. code
Unit price
When [preset only dept.] is entered.
PLU code
Direct PLU key
Unit price
per base q’ty
Unit price
per base q’ty
PLU code
PLU code
Unit price
per base q’ty
Direct PLU key
Unit price
per base q’ty
à
or
å
or
å
PLU/ UPC
PLU/ UPC
PLU/ UPC
PLU/
UPC
PLU/
UPC
or
å
PLU/ UPC
Ä
UPC code
PLU/ UPC
Ä
UPC code
PLU/ UPC
PLU/
UPC
PLU/
UPC
PLU/ UPC
27

Single item cash sale (SICS)/single item finalize (SIF) entries

SICS entries
• This function is useful when a sale is for only one item and is for cash; such as a pack of cigarettes. This function is applicable only to those departments that have been set for SICS or to their associated PLUs, subdepartments or UPCs.
• The transaction is finalized and the drawer opens as soon as you press the department key,
å
key, key,
the direct PLU key or scanning a UPC code.
If an entry to a department, PLU/subdepartment or UPC set for SICS follows entries to departments, PLUs/subdepartments or UPC not set for SICS, it does not finalize and results in a normal sale.
SIF entries
• If an entry to a department, PLU/subdepartment or UPC set for SIF follows entries to departments, PLUs/subdepartments or UPC not set for SIF, the transaction is finalized immediately as a cash sale.
• Like the SICS function, this function is available for single-item cash settlement.
1745
8
1500
For finishing
9
the transaction
PrintKey operation
Example
Note
250
For finishing
9
the transaction
PrintKey operation
Example
PLU/ UPC
28

Scale entries

For making entries for weighed items, a scale may be connected where by the weight is automatically read from the scale. To make refund or return entries, the weight is entered manually while the scale platter is empty and reads zero.
i) Auto scale entries
• Open tare weight: Up to 5 digits (integer + decimal)
• Net weight: Up to 5 digits (integer + decimal)
• Base weight: Up to 2 digits (integer)
The register can be programmed with up to nine tare tables and allows different tares to be assigned to them.
When the
S
key is pressed, the weight is automatically read from the connected scale (option)
and the net weight appears in the register display.
When the item is programmed for “Scale compulsory”, it is not necessary to press the
S
key.
S
200
1
S
1
P
c
PrintKey operation
Example
Note
Procedure
When using a programmed unit price
`
Unit price
per base wt.
Dept. code
Unit price
per base wt.
Department
à
Department
Unit price
When [preset only dept.] is entered.
à
or
å
When you use a programmed tare no.
Tare number
(1-9)
SCALE
When base wt. is 1 LB (or 1 KG)
Base wt.
OPEN TARE
Open tare
weight
Only when you use a base wt. programmed for PLU code
Dept. code
PLU code
PLU code
Unit price
per base wt.
UPC code
PLU code
PLU code
Unit price
per base wt.
UPC code
à
PLU/ UPC
PLU/ UPC
Direct PLU key
Unit price
When [preset only dept.] is entered.
Unit price
per base wt.
Ä
PLU/
UPC
PLU/
UPC
PLU/
UPC
Direct PLU key
Unit price
per base wt.
Ä
PLU/ UPC
à
PLU/ UPC
PLU/ UPC
or
å
or
or
å
å
PLU/ UPC
Loading...
+ 199 hidden pages