SharkRack V210, V240 User Manual

V210/V240-R19-H Rack Mount Kit Installation Guide
SHP900006-000 4/11/05 Rev 2.0 Page 1 of 4
Proprietary Information of SharkRack, Inc. 32920 Alvarado-Niles Rd Suite 250, Union City, CA 94587 510-477-7900 510-324-1664 www.sharkrack.com
V210/V240-R19-H Rack Mount Kit Installation Guide
Step Detail
1. Separate the Slide Assemblies by detaching the Inner Slide Member from the Outer Slide Member. Remove the Inner Slide Member from the Slide Assembly by first fully extending the Inner Slide Member. Next depress the slide stop, which allows for the Inner Slide Member to be detached.
2. Attach the Inner Slide members to both sides of the server using (5) M4 pan head screws.
3. Adjust the Slide Mounting Brackets to the correct Depth. To adjust:
Loosen the two nuts at the rear of the slide using a 11/32” wrench
Move the Rear Slide-Mounting bracket to the correct depth
Tighten the nuts.