Shark Transformer Vac EP602 Owner's Manual

Page 1
OWNER’S MANUAL Model EP602
120V., 60Hz., 10 Amps
EURO-PRO Operating LLC
Boston, MA, 02465 Tel.:
1 (800) 798-7398
www.sharkvac.com
Page 2
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
1
For Household Use Only
Rev. 10/07C
To reduce the risk of fire, electric shock, or injury:
Do not leave the Transformer Vac plugged in when unattended. Unplug the electrical cord when not in use and before servicing.
Do not allow the vacuum to be used as a toy. Close attention is necessary when used by or near children, pets or plants.
• Use only as described in this manual. Use only manufacturer’s recommended accessories.
Do not pull cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners. Keep cord away from heated surfaces.
•Use only extension cords UL-rated or cUL at 15 amperes. Extension cords rated for less amperage may overheat. Care should be taken to arrange the cord so that the cord cannot be pulled or tripped over.
• Turn off all controls as applicable before unplugging from electrical outlet.
Do not handle plug or vacuum with wet hands or operate without shoes.
Do not put any objects into openings. Do not use with any opening blocked. Keep free of dust, lint, hair and anything else that may reduce air flow.
• Store your appliance indoors in a cool, dry area.
• Keep your work area well lit.
• Keep end of hose, wands and other openings away from your face and body.
• Use only on dry surfaces.
• Using improper voltage may result in damage to the motor and possible injury to the user. Correct voltage is listed on rating label.
When using your Transformer Vac basic safety precautions should always be observed, including the following:
1. Read all instructions before using your Transformer Vac.
2. Use the system only for its intended use.
3. To protect ag ain st a risk of electric shock, do not immerse any part of the system in water or other liquids.
4. Never yank cord to disconnect from outlet; instead, grasp plug and pull to disconnect.
5. Do not allow cord to touch hot surfaces.
6. Do not run appliance over cord.
7. Do not operate the system with a damaged cord or plug, or if the appliance or any other part of the system has been dropped or damaged. To avoid the risk of electric shock, do not disassemble or attempt to repair the Transformer Vac. Return the system to EURO-PRO Operating LLC (see warranty) for examination and repair. Incorrect re-assembly or repair can cause a risk of electrical shock or injury to persons when the Transformer Vac is used.
8. Close supervision is necessary for any appliance being used by or near children. Do not leave the system unattended while connected.
9. Keep hair, loose clothing, fingers and all parts of body away from opening and moving parts.
10. Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present.
11. Do not pick up anything that is burning or smoking such as cigarettes, matches or hot ashes.
12. Use extra care when cleaning on stairs.
13. Do not use the vacuum without ALL the filters in place.
14. This appliance is intended only for household use. Follow all user instructions in this manual.
WARNING: To reduce the risk of electric shock, this appliance has a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not modify the plug in any way.
2
GETTING TO KNOW YOUR TRANSFORMER VAC
Technical Specifications
Voltage: 120V., 60Hz. Power: 10 Amps
1. Hand Grip
2. Telescopic Tube
3. Locking Button
4. Flexible Hose
5. Dust Cup Release Button 1
6. Dust Cup Handle
7. Dust Cup (Container)
8. Main Unit
9. Intelli-Sense
TM
Filter
Monitor
10. Exhaust Filter Cover
11. On/Off Switch
12. Power Cord
13. Floor Brush Release Button
14. Floor Brush
15. Crevice Tool
16. Dusting Brush
17. Telescopic Tube Release Button
18. Dust Cup Release Button 2
19. Cord Hook Release
20. Hose Connector
21. Shoulder Strap (not shown)
22. Air Driven Turbo Brush
22
Note: Illustrations may differ from actual unit.
Page 3
PRECAUTIONARY MEASURES
IMPORTANT: If the suction opening in the unit or the hose is BLOCKED, switch off
the vacuum cleaner and remove the blocking substance before you start the unit again.
1. Do not operate the vacuum cleaner too close to heaters, radiators or cigarette butts.
2. Before inserting the power plug into the wall outlet, make sure that your hands are dry.
4. When pulling out the power plug from the wall outlet, pull the plug not the power cord.
3. Before you start vacuuming, make sure to remove large or sharp objects that might damage the dust cup debris screen.
5. Do not pick up anything that is burning or smoking such as cigarettes, matches or hot ashes.
6. Do not use without ALL filters in place.
3
OPERATING INSTRUCTIONS
WARNING: Always remove the power
plug from the wall outlet before assembling or removing accessories.
INSERTING THE TELESCOPIC TUBE INTO THE MAIN UNIT
• Insert the telescopic tube into the hole next to the dust cup handle. Make sure that the slot in the handle fits correctly into the opening. (Fig. 2)
• To remove the telescopic tube, press the telescopic tube release button and pull the tube up.
EXTENDING THE TELESCOPIC TUBE
Push the plastic button and pull out the smaller tube. (Fig. 1)
ATTACHING THE FLOOR BRUSH TO THE MAIN UNIT
• Insert the floor brush into its location, in the direction of the arrow. (Fig. 3)
• To remove the floor brush from the main unit, press on the floor brush release button and pull the floor brush out.
ATTACHING THE HOSE TO THE MAIN UNIT
• Hold the end of the hose.
• Insert the hose into the hose connector. (Fig.4)
4
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Page 4
Fig. 7
OPERATING INSTRUCTIONS
WINDING & UNWINDING THE POWER CORD
This vacuum cleaner is equipped with a convenient cord storage feature. The power cord winds around the two cord holders at the back of the unit. The bottom one has a quick cord release feature. Turn the cord hook to the left or the right to remove the power cord. (Fig. 5)
ON/OFF SWITCH
• The On/Off switch has two different positions.
• Push on the "I" side to turn the vacuum ON.
• Push on the "O" side to turn the vacuum OFF.
USING THE UNIT AS A HAND VACUUM
• Press the telescopic tube release button to remove the telescopic tube. (See Fig. 2 page 4)
• Press the floor brush release button to remove the floor brush. (See Fig 3 page 4)
• Attach the shoulder strap to the shoulder strap attachment point. (Fig. 6)
• Attach the crevice tool or the dusting brush to the end of the hose.
Crevice Tool
For radiators, crevices, corners, baseboards and between cushions.
Dusting Brush
The dusting brush is used for the furniture, venetian blinds, books, lamp shades and shelves.
5
= OFF
= ON
USING THE UNIT AS AN UPRIGHT
• Unwind the power cord and plug into the 120V outlet.
• Push down on the locking button to adjust the height of the telescopic handle.
NOTE: When vacuuming
deep pile carpets or hard to vacuum carpets, lower the angle of the telescopic handle (see illustration at right) for easier maneuverability.
L
o
w
e
r
WARNING
After extended use, the body of the vacuum cleaner may become hot. When using the unit with the shoulder strap, the unit will touch the body of the user. Therefore, make sure that the unit body is cool before you use with the shoulder strap. If during use, the vacuum gets too warm, allow it to cool before continuing to use.
When the Intelli-Sense
TM
Filter Monitor lights up, it means that the dust cup is full or the HEPA filter, non-woven pre-filter or debris screen needs cleaning. You must empty the dust from the dust cup and clean the HEPA filter, non­woven pre-filter and debris screen right away.
Intelli-SenseTMFilter Monitor
OPERATING INSTRUCTIONS
6
Turbine
Tilt Upwards
Locking Latch
From time to time, the turbine of your turbo brush will require cleaning. To do this:
1. Remove the turbo brush from the hose or telescopic extension tube.
2. Slide locking latch forward then tilt the top housing of the brush upwards. The top housing is hinged and will tilt up approximately 45° only.
3. There may be some dust, lint, hair, etc on the turbine wheel. Remove as much of this as possible.
4. You may also use the unit’s hose with crevice tool attached and use the vacuum to remove any additional debris from the turbine.
5. Ensure that the turbine wheel moves freely by rotating it with your finger. If the turbine does not rotate, call Customer Service for help.
6. Once clean, close the top cover of the turbo brush and slide the locking latch toward the rear of the brush to lock.
Attaching the Air Driven Turbo Brush to the Flexible Hose
To use the air driven turbo brush to clean upholstery:
1. Remove the flexible hose from the hose connector. (Fig. 7)
2. Push the air driven turbo brush onto the end of the flexible hose as far as it will go.
Cleaning Air Driven Turbo Brush
Using The Unit With Air Driven Turbo Brush
The efficiency of your air driven turbo brush depends on the bristle brush rotating at high speed. Strong air suction is needed to accomplish this. In order to ensure that maximum air suction is maintained, please read the following instructions:
1. Empty the dust cup frequently.
2. Always shake out the HEPA filter and clean the non-woven pre-filter and the debris screen when emptying the dust cup container.
3. Ensure that the rotating brush is kept free of hair and string which may accumulate and decrease brush performance.
4. Keep air driven turbo brush turbine free of dirt and foreign matter. (See illustration for cleaning instructions.)
Air Driven Turbo Brush
Important: In order to ensure that
maximum air suction is maintained, empty the dust cup frequently and shake out the HEPA filter and clean the non­woven pre-filter and debris screen at the same time. Ensure that the rotating brush is kept free of hair and string which may accumulate and decrease brush performance.
Fig. 5
Fig. 6
Page 5
Fig. 13
7
OPERATING INSTRUCTIONS
Emptying the Dust Cup Container and Cleaning / Changing the Non­Woven Pre-Filter, HEPA Filter & Debris Screen
Important: Do NOT use the vacuum
without the HEPA filter in place.
IMPORTANT
, Please Note: The
“TapClean” HEPA filter will stop most of the microscopic dust particles and airborne allergens from re-entering the air you breathe. Because of this incredible filtration performance, the HEPA filter will quickly accumulate, inside the white filter folds, many fine dust particles that are difficult to see but which will eventually block or reduce your suction power - if not cleaned properly.
1.To remove the dust cup container, first press on the dust cup release button (1) that is located on the dust cup handle and at the same time press on the dust cup release button (2) that is on the side of the upper housing. (Fig. 8) Then pull the dust cup container out.
4.Hold the HEPA filter by the edges and vigorously “TapClean” the HEPA Filter dirty side down on a hard, flat surface until no more dust is observed falling out from between the pleats of the filter. (Fig. 12) We recommend washing the HEPA filter once a month or when suction appears to be reduced. Let the HEPA filter air dry completely for 24 hours.
5.Rinse the non-woven pre-filter and let it air dry completely for 24 hours.
6.Insert the non-woven pre-filter.
7.Reinstall the HEPA filter in the vacuum.
8.To separate the debris screen from the dust cup, hold the dust cup in one hand and turn the dust cup cover counter clockwise and pull apart. To clean the debris screen, we recommend that you rinse it under lukewarm running water to remove the dirt that accumulates on it, but always allow it to completely air dry before inserting back into the vacuum. (Fig. 13)
Warning: Always unplug the
unit from electrical outlet before opening the Dust Cup (container).
Warning: After each Use -
Always remove filter assembly and the dust cup cover with the debris screen, then vigorously “TapClean” HEPA filter and clean debris screen and non-woven pre-filter until no more dust can be removed.
Fig. 9
Fig. 10
Fig. 12
Dust Cup
Release Button 2
Dust
Cup Release Button 1
Fig. 8
HEPA Filter
Non-Woven Pre-Filter
Fig. 11
2. To empty the dust cup container, press on the trap door release button that is on the back side of the dust cup container. (Fig. 9)
3. The HEPA filter is located underneath the dust cup container. (Fig.10) Remove the non-woven pre­filter. (Fig. 11) Remove the HEPA filter, hold the edges and pull it out slowly.
Wash once a month or when suction appears reduced
Fig. A
8
Pre-Motor Filter
Warning: Allow 24
hours for drying before replacing in unit.
Never over fill the dust cup container ­remove dirt and clean the HEPA filter, non­woven pre-filter and debris screen when dirt in dust cup is at or below the "MAX" level during prolonged usage or risk motor damage.
If you wash the HEPA filter or the non­woven pre-filter, make sure that they have completely air dried before inserting back in the vacuum. Please Note:
The HEPA Filter is washable. It should, however, be replaced every three (3) to six (6) months to ensure peak performance of your vacuum. The non-woven pre-filter, pre-motor and post motor filters are washable.
Important: Make sure that ALL filters
have completely air dried before re­installing back in the vacuum.
Warning: Always empty the dust cup
container and clean the HEPA filter, non-woven pre-filter and debris screen before each use and during prolonged usage.
CAUTION: The suction hole must be
open, free of any obstructions at all times. Otherwise, the motor will overheat and could become damaged.
Fig. 14
Fig. 15
Changing & Cleaning the Post Motor Filter
The post motor filter is a washable filter.
• Remove the filter cover from the front of the unit and remove the filter. (Fig. 15)
• Rinse the post motor filter in lukewarm water and air dry the filter completely for 24 hours. Do not use a washing machine to rinse the filter. Do not use a hair dryer to dry it. Air dry only. Never operate the vacuum without the post motor filter in place.
• When the filter is dry, replace into the filter cover and replace the filter cover to the unit.
• A severely soiled or clogged filter should be thoroughly washed with lukewarm water. A mild detergent can be used if required.
OPERATING INSTRUCTIONS
Changing & Cleaning the Pre­Motor Filter
The pre-motor filter is a washable filter.
• Remove the dust cup container, the non-woven pre- filter and the HEPA filter to remove the pre-motor filter. (Fig 14)
• Rinse the pre-motor filter in lukewarm water and air dry the filter completely for 24 hours. Do not use a washing machine to rinse the filter. Do not use a hair dryer to dry it. Air dry only. Never operate the vacuum without the pre-motor filter in place.
• When the filter is dry, replace into the unit and replace the HEPA filter and dust cup container.
• A severely soiled or clogged filter should be thoroughly washed with lukewarm water. A mild detergent can be used if required.
PLEASE NOTE
: The white pleated filter material in the HEPA filter will discolor over time -This is NORMAL and will NOT affect the performance of the filter. If the HEPA filter is properly "TapCleaned” after each use and suction does not return to 100%, then we suggest that the HEPA filter be “TapCleaned” vigorously until no more dust can be removed, then rinsed under the faucet and allowed to dry for 24 hours before refitting into the vacuum. (Fig. A) This should be done
once a month or when suction appears to be reduced.
Page 6
TROUBLE SHOOTING GUIDE
OPERATING INSTRUCTIONS
IMPORTANT: This unit is equipped
with a motor protective thermostat. If for some reason the vacuum cleaner should overheat, the thermostat will automatically turn the unit off. Should this occur:
• Push the On/Off button once.
• Disconnect the plug from the power source.
• Check the source of overheating problem. (i.e. clogged hose or filter)
Motor Thermostat
• If clogged hose or filter is found, unclog the hose and replace the filters.
• Wait at least 45 minutes before attempting to reuse the vacuum.
• After unit has cooled down for 45 minutes, plug in the cleaner and push the On/Off button. The vacuum should start again.
• If the vacuum still does not start, contact customer service at 1 (800) 798-7398.
9
PROBLEM POSSIBLE REASON POSSIBLE SOLUTION
VACUUM WILL NOT OPERATE
1. Power cord not firmly plugged into outlet.
2. No power in wall outlet.
3. Needs servicing.
4. Thermostat has tripped.
1. Plug unit in firmly.
2. Check fuse or breaker. Replace fuse/reset breaker.
3. Call 1 (800) 798-7398.
4. Turn the unit off and unplug from outlet. Allow unit to cool down, then restart.
VACUUM WILL NOT PICK-UP OR SUCTION POWER IS WEAK
1. Dust cup is full.
2. Unit clogged.
3. HEPA Filter needs cleaning or replacing.
4. Debris screen needs cleaning.
5. Filters need cleaning
1. Empty and clean dust cup.
2. Turn unit off and unplug from wall outlet. Remove Dust Cup Filter and check for object(s) in air duct and remove.
3. Clean or replace HEPA Filter.
4. Clean debris screen.
5. Clean Filters
TURBO BRUSH DOES NOT ROTATE OR ROTATES SLOWLY
1. Dust cup is full.
2. Rotating brush or elbow is obstructed.
3. Belt is broken.
4. Hose obstructed.
5. Debris screen is clogged.
6. Filters need cleaning.
1. Empty dust cup.
2. Clear obstructions.
3. Call 1 (800) 798-7398.
4. Clear obstruction.
5. Clean debris screen.
6. Clean All filters.
DUST ESCAPING FROM VACUUM
1. Dust cup is full.
2. Dust cup is not installed correctly.
1. Empty and clean dust cup.
2. Review Dust cup instructions.
VACUUM, HOSE OR BRUSHES WILL NOT PICK-UP
1. Hose clogged.
2. Dust cup is full.
1. Remove hose and/or brushes. Remove obstruction from hose and/or brush.
2. Empty and clean dust cup.
Please Note:
The HEPA Filter is washable. It should, however, be replaced every three (3) to six (6) months to ensure peak performance of your vacuum.
The Pre-Motor, the Non-Woven Pre-Filter and Post Motor Filters are washable.
Important:
Make sure that ALL filters have been completely air dried for 24 hours before re-installing back in the vacuum.
ORDERING REPLACEMENT DUST CUP FILTERS
TO ORDER REPLACEMENT HEPA FILTERS
Item # XSH602
for Model EP602
Call: 1 (800) 798-7398
Monday to Friday 8:30 A.M. - 5:00 P.M. Eastern Standard Time
or
visit our website: www.sharkvac.com
FOR TECHNICAL SUPPORT
for Model EP602
Call: 1 (800) 798-7398
Monday to Friday 8:30 A.M. - 5:00 P.M. Eastern Standard Time
10
Page 7
ONE (1) YEAR LIMITED WARRANTY
EURO-PRO Operating LLC warrants this product to be free from defects in material and workmanship for a period of one (1) year from the date of the original purchase, when utilized for normal household use, subject to the following conditions, exclusions and exceptions.
If your appliance fails to operate properly while in use under normal household conditions within the warranty period, return the complete appliance and accessories, freight prepaid. For Customer Service support, call 1 (800) 798-7398 or visit our website at www.sharkvac.com.
If the appliance is found by EURO-PRO Operating LLC to be defective in material or workmanship, EURO-PRO Operating LLC will repair or replace it free of charge. Proof of purchase date and $ 9.95 to cover the cost of return shipping and handling must be included. * Non-durable parts including, without limitation, filters, brushes and electrical parts which normally require replacement are specifically excluded from warranty.
The liability of EURO-PRO Operating LLC is limited solely to the cost of the repair or replacement of the unit at our option. This warranty does not cover normal wear of parts and does not apply to any unit that has been tampered with or used for commercial purposes. This limited warranty does not cover damage caused by misuse, abuse, negligent handling or damage due to faulty packaging or mishandling in transit. This warranty does not cover damage or defects caused by or resulting from damages from shipping or repairs, service or alterations to the product or any of its parts, which have been performed by a repair person not authorized by EURO-PRO Operating LLC.
This warranty is extended to the original purchaser of the unit and excludes all other legal and/or conventional warranties. The responsibility of EURO-PRO Operating LLC if any, is limited to the specific obligations expressly assumed by it under the terms of the limited warranty. In no event is EURO-PRO Operating LLC liable for incidental or consequential damages of any nature whatsoever. Some states do not permit the exclusion or limitation of incidental or consequential damages, so the above may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state or province to province.
*Important: Carefully pack item to avoid damage in shipping. Be sure to include proof of purchase date and to attach tag to item before packing with your name, complete address and phone number with a note giving purchase information, model number and what you believe is the problem with item. We recommend you insure the package (as damage in shipping is not covered by your warranty). Mark the outside of your package “ATTENTION CUSTOMER SERVICE”. We are constantly striving to improve our products, therefor e the specifications contained herein are subject to ch ang e w i thout notic e .
OWNERSHIP REGISTRATION CARD
FOR CANADIAN CONSUMERS ONLY
Please fill out and mail the product registration card within ten (10) days of purchase. The registration will enable us to contact you in the unlikely event of a product safety notification. By returning this card you acknowledge to have read and understood the instructions for use, and warnings set forth in the accompanying instructions.
RETURN TO: EURO-PRO Operating LLC, 4400 Bois Franc, St. Laurent, Quebec, H4S 1A7
______________________________________________________________________
Appliance model
______________________________________________________________________
Date purchased Name of store
______________________________________________________________________
Owner’s name
______________________________________________________________________
Address City Prov. Postal code
Printed in China
Model EP602
11
Model EP602
Loading...