SGS Thomson Microelectronics TSM112CN, TSM112CDT, TSM112CD, TSM112 Datasheet

1/7
OVER VOLTAGE PROTECTION FOR 3.3V
5V AND 12V WITHOUT EXTERNAL COM­PONENTS
UNDER VOLTAGE PROTECTION FOR 3.3V
5V AND 12V WITHOUT EXTERNAL COM­PONENTS
OVER VOLTAGE PROTECTION FOR -12V
OR -5V W I T H EX TERNAL COMPON E N TS
EXTERNALLY ADJUSTABLE UNDER VOLT-
POWER GOOD I N PUT / OU TP U T
EXTERNALLY ADJUSTABLE PG DELAY
F AULT OUTPUT
REMOTE OUTPUT
EXTERNALLY ADJUSTABLE REMOTE
DELAY
PRECISION VOLTAGE REFERENCE
2kV ESD PROTECTION
DESCRIPTION
The TSM112 integrated circuit incorporates all sensing circuitry to regulate and protect from over voltage and under voltage a multiple output power supply (3.3V, 5V and 12V). TSM112 incorporat es all the nec essary functions for Housekeeping features whi ch allow s afe oper­ation in all conditions, and very hi gh system inte­gration. TSM112 integrates a precise voltage reference.
APPLICATION
PC SMPS Triple Power Line Housekeeping
IC (3.3V 5V 12V)
ORDER CODE
N = Dual in Line Package (DIP) D = Small Outline Package (SO) - also available in Tape & Reel (DT)
PIN CONNECTIONS (top view)
Part
Number
Temperature
Range
Package
Marking
ND
TSM112CN 0 to 85°C
TSM112C
TSM112CD 0 to 85°C
M112
N
DIP14
(Plastic Package)
D
SO14
(Plastic Micropackage)
VCC
REM
TREM
TPG
PG
VS33
VS5
VS12
PI
TUV
EP
GND VREF
10
9 87
6
5
4
3
2
1
11
12
1314FAUL
T
January 2001
TSM112
3.3V 5V 12V HOUSEKEEPING IC
TSM112
2/7
PIN DESCRIPTION
ABSOLUTE MAXIMUM RATINGS
OPERATING CONDITIONS
Name Pin # Type Function
Vcc 14 Power Supply Positive Power Supply Line
Gnd 7 Power Supply Ground Line. 0V Reference For All Voltages
Vs12 3 Analog Input
Over and Under voltage Sense Input Dedicated to the 12V Line
1)
Vs5 2 Analog Input
Over and Under voltage Sense Input Dedicated to the 5V Line
1)
Vs33 1 Analog Input
Over and Under voltage Sense Input Dedicated to the 3.3V Line
1)
Tuv 6 Timing Capacitor Adjustable Under voltage Blanking Delay at Power Up (Setting Capacitor)
Fault 13 Open Collector Fault Output. Fault is high when Over or Under Voltage has been Detected
PI 5 Analog Input Power Good Input. Detection of the Power Conditions
PG 12 Open Collector Power Good Output. PG output is High when the Power Conditions are
OK
Tpg 11 Timing Capacitor Adjustable Power Good Delay (Setting Capacitor)
REM 9 Logic Input Input Remote Control of the Complete System by the Motherboard
(µController). Remote is active high. Switch OFF/ON of the Power Supply. Reset of the Complete System after a FAULT Activation.
Trem 10 Timing Capacitor Adjustable Remote Delay (Setting Capacitor).
Vref 8 Voltage Reference 2.5V Reference for all Voltages
EP 4 Analog Input Extra Protection Circuit. Can be used for -12V or -5V Over Voltage
Protection.
1. Over and Under Voltage Inputs can go higher than Vcc within the allowed Max Rating range
Symbol DC Supply Voltage Value Unit
Vcc
DC Supply Voltage
1)
25 V
Iout Output Current Power Good 30 mA
Io Output current for the Voltage reference 20 mA
VFault Fault Ouput 5 V
Top Operating Free Air Temperature Range -55 to 125 °C
Pd Power Dissipation 0.7 W
Tstg Storage Temperature -55 to 150 °C
ESD Electrostatic Discharge 2 kV
Tuv Adjustable Under voltage Blanking At Power UP 5 V
EP Extra Protection 5 V
PI Power Good Input 5 V
PG Power Good Output 5 V
Tpg Adjustable Power Good Delay 5 V REM Remote Control 5 V Trem Adjustable Remote Delay 5 V
1. All voltage values, except differential voltage are with respect to network ground terminal.
Symbol Parameter Value Unit
Vcc DC Supply Conditions 4.5 to 24 V
Toper Operating Free Air Temperature Range 0 to 85 °C
TSM112
3/7
ELECTRICAL CHARACTERISTICS Tamb = 25°C and Vcc = 17V (unless otherwise specified)
Symbol Parameter Test Condition Min Typ Max Unit
Total Current Consumption
Icc Total Supply Current 3 5 mA
Over Voltage and Under Voltage Protection
Vov33 Over Voltage Sense 3.3V Input can go higher than
Vcc
3.8 4 4.2 V
Vov5 Over Voltage Sense 5V Input can go higher than
Vcc
5.8 6.1 6.4 V
Vov12 Over Voltage Sense12V Input can go higher than
Vcc
13.4 14.2 15 V
Vuv33 Under Voltage Sense 3.3V 2.1 2.3 2.5 V
Vuv5 Under Voltage Sense 5V 3.7 4 4.3 V
Vuv12 Under Voltage Sense 12V 9.2 10 10.8 V
Vep Extra Over voltage Protection Threshold 1.28 V
Tfault Fault Delay Before Latching Internally Fixed Delay 100
µ
s
Under Voltage Blanking During Power Up
Tuv Under Voltage Blanking During Power
Up (Vcc rising)
Cuv = 2.2µF Adjustable Blanking
100 300 500 ms
Thuv Blanking Threshold 1.28 V
Power Good (PG)
Vpgth Power Good Voltage Threshold 1.28 V
Vpghyst Power Good Voltage Threshold
Hysteresis
70 mV
Vpgol Low Output Open Collector Saturation
Voltage
Collector Current = 15mA 0.4 V
Ipgoh High Output Open Collector Leakage
Current
PG Output = 5V 1
µ
A
Tpgr Power Good Output Rise Time Load Capacitor = 100pF 1
µ
s
Tpgf Power Good Output Fall Time Load Capacitor = 100pF 1
µ
s Tpg Power Good Adjustable Delay Load Capacitor Cpg=2.2µF 100 300 500 ms PIth Power Input Detection Threshold 1.28 V
Fault
Vfaultol Fault Output Saturation Voltage Level IFault = 1mA 1 V Ifaultoh Fault Output Leakage Current Level Vfault = 5V 1 µA
Remote Control (REM)
Vremth Remote ON/OFF Input Voltage
Threshold
0.7 0.8 1 V
Vremih High Input Remote Voltage 3.3 3.4 V
Iremil Low Input Remote Saturation Current 0.5 mA
Trem1 Remote Adjustable Delay ON to OFF Load Capacitor
Crem=0.1µF
40 50 60 ms
Trem2 Remote Adjustable Delay OFF to ON Load Capacitor
Crem=0.1µF
40 50 60 ms
Voltage Refer ence
Vref Internal Voltage Reference Io = 0mA 2.46 2.5 2.54 V
Regline Line regulation Io = 0mA
4.5V<Vcc<24V
410mV
Regline Line regulation Io = 10mA
4.5V<Vcc<24V
15 mV
Regload
Load regulation
1)
0<Io<10mA 25 mV
1. Do not short circuit the Vref Pin
Loading...
+ 4 hidden pages