TS4040
3/10
ELECTRICAL CHARACTERISTICS
TS4040E (2% Precision)
Tamb = 25°C (unless otherwise specified)
ELECTRICAL CHARACTERISTICS
TS4040D (1% Precision)
Tamb = 25°C (unless otherwise specified)
Symbol Parameter Test Condition Min. Typ. Max. Unit
Vk
Reverse Breakdown Voltage Ik = 100µA 2.45 2.5 2.55 V
Reverse Breakdown Voltage Tolerance
Ik = 100µA
-40°C < T < +85°C
-50
-74
50
74
mV
Ikmin Minimum Operating Current
T = 25°C 40 65
µ
A
-40°C < T < +85°C 70
∆
Vref/∆T Average Temperature Coefficient Ik = 100µA 30 150 ppm/°C
∆
Vk/∆Ik
Reverse Breakdown Voltage Change
with Operating Current Range
Ikmin < Ik < 1mA
-40°C < T < +85°C
0.4 1
1.2
mV
1mA < Ik < 15mA
-40°C < T < +85°C
2.5 8
10
Rka Reverse Static Impedance
Ik = Ikmin to 1mA
-40°C < T < +85°C
0.4 1
1.2
Ω
Ik = 1 to 15mA
-40°C < T < +85°C
0.2 0.6
0.7
Kvh Long Term Stability Ik = 100µA, t = 1000hrs 120 ppm
En Wide Band Noise
Ik = 100µA
10Hz < f < 10kHz
35
µ
Vrms
Note: Limits are 100% production tested at 25°C. Limits over temperature are guaranteed through correlation and by design.
Symbol Parameter Test Condition Min. Typ. Max. Unit
Vk
Reverse Breakdown Voltage Ik = 100µA 2.475 2.5 2.525 V
Reverse Breakdown Voltage Tolerance
Ik = 100µA
-40°C < T < +85°C
-25
-49
25
49
mV
Ikmin Minimum Operating Current
T = 25°C 40 65
µ
A
-40°C < T < +85°C 70
∆
Vref/∆T Average Temperature Coefficient Ik = 100µA 30 150 ppm/°C
∆
Vk/∆Ik
Reverse Breakdown Voltage Change
with Operating Current Range
Ikmin < Ik < 1mA
-40°C < T < +85°C
0.4 1
1.2
mV
1mA < Ik < 15mA
-40°C < T < +85°C
2.5 8
10
Rka Reverse Static Impedance
Ik = Ikmin to 1mA
-40°C < T < +85°C
0.4 1
1.2
Ω
Ik = 1mA to 15mA
-40°C < T < +85°C
0.2 0.6
0.7
Kvh Long Term Stability Ik = 100µA, t = 1000hrs 120 ppm
En Wide Band Noise
Ik = 100µA
10Hz < f < 10kHz
35
µ
Vrms
Note: Limits are 100% production tested at 25°C. Limits over temperature are guaranteed through correlation and by design.