ABSOLUTE MAXIMUM RATINGS
OPERATING CONDITIONS
Symbol Parameter Value Unit
V
CC
Supply voltage
1)
7V
V
id Differential Input Voltage
2)
±1V
V
iInput Voltage
3)
-0.3 to VCC+0.3
V
T
oper
Operating Free Air Temperature Range -40 to + 125 °C
T
std
Storage Temperature -65 to +150 °C
T
j
Maximum Junction Temperature 150 °C
R
thjc Thermal Resistance Junction to Case
4)
SOT23-5
DIP8
DIP14
SO8
SO14
TSSOP8
TSSOP14
81
42
32
28
22
26
21
°C/W
R
thja
Thermal Resistance Junction to Ambient - SOT23-5 256 °C/W
ESD Human Body Model 2 kV
Lead Temperature (soldering, 10sec) 260 °C
1. All voltages values, except differential voltage are with respect to network terminal.
2. Differential voltages are non-inverting input terminal with respect to the inverting input terminal.
3. The magnitude of input and output voltages must never exceed V
CC
+0.3V.
4. Short-circuits can cause excessive heating. Destructive dissipation can result from simultaneous short-circuit on all amplifiers
Symbol Parameter Value Unit
V
CC
Supply Voltage 1.8 to 6 V
V
icm
Common Mode Input Voltage Range
1)
Vee-0.2 to VCC+ 0.2
V
V
icm Common Mode Input Voltage Range
2)
Veeto V
CC
V
1. At 25°C, for 1.8 ≤ VCC≤ 6V, V
icm
is extended to Vee- 0.2V, VCC+ 0.2V.
2. In full temperature range, bothRails can be reached when V
CC
does not exceed 5.5V.