ELECTRICAL CHARACTERISTICS
(T
amb
=25°C; V
DD1
= 5V; V
DD2
= 10V; f
OSC
= 4MHz; unless other-
wise specified).
Symbol Parameter Test Condition Min. Typ. Max. Unit
V
DD1
Supply Voltage 4.5 5.0 5.5 V
V
DD2
Supply Voltage 9.0 11.0 V
I
DD1 Supply Current no output load 2 4 6 mA
I
DD2
Supply Current PLL locked 1 2 3 mA
I
DD1 STB
Supply Current Standby mode 1
µ
A
RF INPUT (AM_IN, FM_IN)
f
iAM
Input Frequency AM Vi = 100mV
rms
sinusoidal 0.5 64 MHz
f
iFM Input Frequency FM Vi = 100mV
rms
sinusoidal 30 200 MHz
V
iMIN
Min Input Voltage AM 0.5 to 16MHz range sinusoidal 30 mVrms
V
iMAX
Max Input Voltage AM 0.6 to 16MHz range sinusoidal 600 mVrms
V
iMIN Min Input Voltage FM 70 to 120MHz range sinusoidal 30 mVrms
V
iMAX
Max Input Voltage FM 70 to 120MHz range sinusoidal 600 mVrms
Z
in Input Impedance FM input 3 4 5 KΩ
Z
in
Input Impedance AM input 3 4 5 KΩ
IF COUNTER (IF_AM, IF_FM)
f
iAM Input Frequency range AM Vi = 100mV
rms
0.400 11 MHz
f
iAM
Input Frequency range FM Vi = 100mV
rms
10 11 MHz
V
iMIN Min Input Voltage AM IF pin f
in
= 455kHz 30 mVrms
V
iMIN
Min Input Voltage FM IF pin fin= 10.7MHz 30 mVrms
V
iMAX
Max Input Voltage AM IF pin fin= 455kHz 600 mVrms
V
iMAX Max Input Voltage FM IF pin f
in
= 10.7MHz 600 mVrms
Z
in
Input Inpedance FM IF pin 3 4 5 KΩ
Z
in Input Inpedance AM IF pin 3 4 5 KΩ
BUS INTERFACE
T
j
Noise Suppression Time
Constant on SCL, SDA Input
50 ns
f
SCL
SCL Clock Frequency 400 kHz
t
AA SCL Low to SDA Data Valid 300 ns
t
buf
Time the bus must be free for
the new transmission
4.7 µs
t
HD-START
START Condition hold time 4.0
µ
s
t
LOW
Clock Low Period 4.7 µs
t
HIGH
Clock High Period 4.0 µs
t
SU-SDA
Start Condition Setup Time 4.7
µ
s
t
HD-DATA Data Input Hold Time 1 µs
t
SU-DATA
Data Input Setup Time 250 ns
t
R SDA & SCL Rise Time 1 µs
t
F
SDA & SCL Full Time 0.3 µs
t
SU-STOP
Stop Condition Setup Time 4.7
µ
s
t
DH DATA OUT Time 300 ns
TDA7427A
4/21