SGS Thomson Microelectronics STTH806TTI Datasheet

®
STTH806TTI
TURBOSWITCH Tandem 600V ULTRA-FAST BOOST DIODE
MAJOR PRODUCTS CHAR ACTERISTICS
I
F(AV)
V
RRM
8 A
600 V (in series)
Tj (max) 150 °C
V
(max) 2.6 V
F
(typ.) 4 A
I
RM
FEATURES AND BENE FITS
ESPECIALLY SUITED AS BOOST DIODE IN CONTINUOUS MODE POWER FACTOR CORRECTORS AND HARD SWITCHING CONDITIONS.
DESIGNED FOR HIGH DI/DT OPERATION. ULTRA-FAST RECOVERY CURRENT TO
COMPETE WITH GaAs DEVICES. SIZE DIMINUTION OF MOSFET AND HEATSINKS ALLOWED.
INTERNAL CERAMIC INSULATED PACKAGE ALLOWS FLEXIBLE HEATSINKING ON COMMON OR SE PAR AT E HEAT SINK .
MATCHED DIODES FOR TYPICAL PFC APPLICATION WITHOUT VOLTAGE BALANCE NETWORK.
INSULATED VERSION: : Insulated voltage = 2500 V
(RMS )
Capacitance = 7 pF
123
3
2
1
Insulated TO-220AB
DESCRIPTION
The TURBOSWITCH "H" is an ultra high performance diode composed of two 300V dice in series. TURBOSWITCH "H" family drastically cuts losses in the associated MOSFET when run at
F
/dt.
high dI
ABSOLUTE RATINGS (limiting values for both diodes in series)
Symbol Parameter Value Unit
V
RRM
I
F(RMS)
I
FSM
T
stg
Tj
TM: TURBOSWITCH is a trademark of STMicroelectronics
November 1999 - Ed: 3A
Repetitive peak reverse voltage RMS forward current Surge non repetitive forward current tp = 10 ms sinusoidal Storage temperature range Maximum operating junction temperature
600 V
14 A 80 A
-65 +150 °C + 150 °C
1/5
STTH806TTI
THERMAL AND POWER DATA
Symbol Parameter Test conditions Value Unit
R
R
R
th (j-c)
th (c)
th (j-c)
P
Junction to case thermal resistance Per diode
Junction to case thermal resistance Total
1
Conduction power dissipation for both diodes
Coupling
I
= 8 A δ = 0.5
F(AV)
Tc = 80°C
STATIC ELECTRICAL CHARACTE RISTICS (for both diodes)
Symbol Parameter Tests Conditions Min. Typ. Max. Unit
5 °C/W
0.2
2.6 27 W
*
I
R
V
F
Reverse leakage current
**
Forward voltage drop I
V
R
= V
RRM
Tj = 25 °C Tj = 125°C
= 8 A Tj = 25°C
F
Tj = 125°C
15 100
2.1 2.6
10 µA
3.6 V
Pulse test : * tp = 5 ms, δ < 2 % ** tp = 380 µs, δ < 2%
To evaluate the maximum conduction losses use the following equation : P = 1.8 x I
F(AV)
+ 0.1 I
F2(RMS)
RECOVERY CHARA CTERISTICS
Symbol Tests Conditions Min. Typ. Max. Unit
trr
I
RM
S
factor
= 0.5 A Irr = 0.25 A IR = 1 A Tj = 25°C
I
F
I
= 1 A dIF/dt = - 50 A/µs VR = 30 V
F
VR = 400 V IF = 8 A dIF/dt = -200 A/µs Tj = 125°C
13 ns
30
45.5 A
0.4 -
TURN-ON SWITCHING CHARACT ERISTICS
Symbol Tests Conditions Min. Typ. Max. Unit
2/5
tfr
V
FP
= 8 A dIF/dt = 100 A/µs,
I
F
measured at 1.1 x V
max
F
Tj = 25°C
IF = 8 A dIF/dt = 100 A/µs Tj = 25°C
200 ns
7V
Loading...