SGS Thomson Microelectronics M58CR064Q, M58CR064P, M58CR064D Datasheet

64 Mbit (4Mb x 16, Dual Bank, Burst )

FEATURES SUMMARY

SUPPLY VOLTAGE
= 1.65V to 2V for Program, Erase and
–V
Read –V –V
SYNCHRONOUS / ASYNCHRONOUS READ
– Synchronous Burst Read mode : 54MHz – Asynchronous/ Synchronous Page Read
– Random Access: 85, 90, 100, 120ns
PROGRAMMING TIME
– 10µs by Word typical – Double/Quadruple Word Program option
MEMORY BLOCKS
– Dual Bank Memory Array: 16/48 Mbit – Parameter Blocks (Top or Bott o m location)
DUAL OPERATIONS
– Program Erase in one Bank while Read in
– No delay between Read and Write operations
BLOCK LOCKING
– All blocks locked at Power up – Any combination of blocks can be locked –WP
SECURITY
– 128 bit user programmable OTP cells – 64 bit unique device number – One parameter block permanently lockable
COMMON FLASH INTERFACE (CFI)
100,000 PROGRAM/ERASE CYCLES per
BLOCK
= 1.65V to 3.3V for I/O Buffers
DDQ
= 12V for fast Program (optional)
PP
mode
other
for Block Lock-Down
M58CR064C, M58CR064D M58CR064P, M58CR064Q
1.8V Supply Flash Memory

Figure 1. Package

FBGA
TFBGA56 (ZB)
6.5 x 10mm
ELECTRONIC SIGNATURE
– Manufacturer Code: 20h – Top Device Code, M58CR064C: 88CAh – Bottom Device Code, M58CR064D: 88CBh – Top Device Code, M58CR064P: 8801h – Bottom Device Code, M58CR064Q: 8802h
1/70June 2003
M58CR064C, M58CR064D, M58CR064P, M58CR064Q

TABLE OF CONTENTS

SUMMARY DESCRIPTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Figure 2. Logic Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Table 1. Signal Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Figure 3. TFBGA Connections (Top view through package). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Table 2. Bank Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Figure 4. Memory Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
SIGNAL DESCRIPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Address Inputs (A0-A21). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Data Input/Output (DQ0-DQ15). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Chip Enable (E). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Output Enable (G). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Write Enable (W). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Write Protect (WP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Reset/Power-Down (RP). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Latch Enable (L). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Clock (K).. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Wait (WAIT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Supply Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
V
DD
Supply Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
V
DDQ
V
Program Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
PP
V
Ground. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
SS
Ground. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
V
SSQ
BUS OPERATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Bus Read. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Bus Write. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Address Latch.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Output Disable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Standby. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Reset. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Table 3. Bus Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
COMMAND INTERFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Table 4. Command Codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
COMMAND INTERFACE - STANDARD COMMANDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Read Array Command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Read Status Register Command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Read Electronic Signature Comma nd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Read CFI Query Command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Clear Status Register Command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Block Erase Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Program Command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Program/Erase Suspend Comm and . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2/70
M58CR064C, M58CR064D, M58CR064P, M58CR064Q
Program/Erase Resume Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Protection Register Program Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Set Configuration Register Command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Block Lock Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Block Unlock Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Block Lock-Down Command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Table 5. Standard Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 6
Table 6. Electronic Signature Codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Figure 5. Security Block and Protection Register Memory Map . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
COMMAND INTERFACE - FACTORY PROGRAM COMMANDS. . . . . . . . . . . . . . . . . . . . . . . . . 18
Bank Erase Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 8
Double Word Program Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Quadruple Word Program Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Table 7. Factory Program Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
STATUS REGISTER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Program/Erase Controller Status Bit (SR7). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Erase Suspend Status Bit (SR6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Erase Status Bit (SR5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 0
Program Status Bit (SR4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 0
V
Status Bit (SR3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
PP
Program Suspend Status Bit (SR2). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Block Protection Status Bit (SR1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1
Reserved Bit (SR0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Table 8. Status Register Bits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1
CONFIGURATION REGISTER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Read Select Bit (CR15) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
X-Latency Bits (CR13-CR11) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Power-Down Bit (CR10) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2
Wait Configuration Bit (CR8). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2
Burst Type Bit (CR7). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Valid Clock Edge Bit (CR6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2
Wrap Burst Bit (CR3). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Burst length Bits (CR2-CR0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Table 9. Configuration Register. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Table 10. Burst Type Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Figure 6. X-Latency and Data Output Configuration Exampl e . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Figure 7. Wait Configuration Example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
READ MODES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Asynchronous Read Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Synchronous Burst Read Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Single Synchronous Read Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
3/70
M58CR064C, M58CR064D, M58CR064P, M58CR064Q
DUAL OPERATIONS AND MULTIPLE BANK ARCHITECTURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Table 11. Dual Operations Allowed In Other Bank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Table 12. Dual Operations Allowed In Same Bank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
BLOCK LOCKING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Reading a Block’s Lock Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Locked State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Unlocked State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 8
Lock-Down State. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Locking Operations During Erase Suspend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Table 13. Lock Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
PROGRAM AND ERASE TIMES AND ENDURANCE CYCLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Table 14. Program, Erase Times and Program, Erase Endurance Cycles . . . . . . . . . . . . . . . . . . . 30
MAXIMUM RATING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Table 15. Absolute Maximum Ratings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
DC and AC PARAMETERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2
Table 16. Operating and AC Measurement Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Figure 8. AC Measurement I/O Waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Figure 9. AC Measurement Load Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Table 17. Capacitance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Table 18. DC Characteristics - Currents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Table 19. DC Characteristics - Voltages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Figure 10. Asynchronous Random Access Read AC Waveforms. . . . . . . . . . . . . . . . . . . . . . . . . . 35
Figure 11. Asynchronous Page Read AC Waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Table 20. Asynchronous Read AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Figure 12. Synchronous Burst Read AC Waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Figure 13. Single Synchronous Read AC Waveforms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Table 21. Synchronous Read AC Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Figure 14. Write AC Waveforms, Write Enable Controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Table 22. Write AC Characteristics, Write Enable Controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Figure 15. Write AC Waveforms, Chip Enable Controlled. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Table 23. Write AC Characteristics, Chip Enable Controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Figure 16. Reset and Power-up AC Waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Table 24. Reset and Power-up AC Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
PACKAGE MECHANICAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Figure 17. TFBGA56 6.5x10mm - 8x7 ball array, 0.75 mm pitch, Bottom View Package Outline. . 46
Table 25. TFBGA56 6.5x10mm - 8x7 ball array, 0.75 mm pitch, Package Mechanica l Data . . . . . 46
Figure 18. TFBGA56 Daisy Chain - Package Connections (Top view through package) . . . . . . . . 47
Figure 19. TFBGA56 Daisy Chain - PCB Connection Proposal (Top view through package). . . . . 48
PART NUMBERING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Table 26. Ordering Information Scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
4/70
M58CR064C, M58CR064D, M58CR064P, M58CR064Q
Table 27. Daisy Chain Ordering Scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
APPENDIX A. BLOCK ADDRESS TABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Table 28. Top Boot Block Addresses, M58CR064C, M58CR064P. . . . . . . . . . . . . . . . . . . . . . . . . 50
Table 29. Bottom Boot Block Addresses, M58CR064D, M58CR064Q . . . . . . . . . . . . . . . . . . . . . . 52
APPENDIX B. COMMON FLASH INTERFACE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Table 30. Query Structure Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
Table 31. CFI Query Identification String . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
Table 32. CFI Query System Interface Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Table 33. Device Geometry Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55
Table 34. Primary Algorithm-Specific Extended Query Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Table 35. Burst Read Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
APPENDIX C. FLOWCHARTS AND PSEUDO CODES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Figure 20. Program Flowchart and Pseudo Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Figure 21. Double Word Program Flowchart and Pseudo code . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Figure 22. Quadruple Word Program Flowchart and Pseudo Code . . . . . . . . . . . . . . . . . . . . . . . . 60
Figure 23. Program Suspend & Resume Flowchart and Pseudo Code . . . . . . . . . . . . . . . . . . . . . 61
Figure 24. Block Erase Flowchart and Pseudo Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Figure 25. Erase Suspend & Resume Flowchart and Pseudo Code. . . . . . . . . . . . . . . . . . . . . . . . 63
Figure 26. Locking Operations Flowchart and Pseudo Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Figure 27. Protection Register Program Flowchart and Pseudo Code . . . . . . . . . . . . . . . . . . . . . . 65
APPENDIX D. COMMAND INTERFACE STATE TABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Table 36. Command Interface States - Lock table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Table 37. Command Interface States - Modify Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
REVISION HISTORY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Table 38. Document Revision History. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
5/70
M58CR064C, M58CR064D, M58CR064P, M58CR064Q

SUMMARY DESCRIPTION

The M58CR064 is a 64 Mbit (4Mbit x16) non-vola­tile Flash memory that may be erased electrically at block level and programmed in-system on a Word-by-Word basis using a 1.65V to 2V V ply for the circuitry and a 1.65V to 3.3V V ply for the Input/Output pins. An optional 12V V
DDQ
sup-
sup-
PP
power supply is provided to speed up customer programming. In M58CR064C and M58CR064D the V
pin can also be used as a control pi n to
PP
provide absolute protection against program or erase. In M58CR064P and M58CR064Q this fea­ture is disabled.
The device features an asymmet rical block archi­tecture. M58CR064 has an array of 13 5 blocks, and is divided into two banks, Banks A and B. The Dual Bank Architecture allows Dual Operations, while programming or erasing in one bank , Read operations are possible in the other bank. Only one bank at a time is allowed to be in Program or Erase mode. It is possible to perform burst reads that cross bank boundaries. The bank architecture is summarized in Table 2, and the mem ory maps are shown in Figure 4. The Parameter Blocks are located at the top of the memory address space for the M58CR064C and M58CR064P, and at the bot­tom for the M58CR064D and M58CR064Q.
Each block can be erased separately. Erase can be suspended, in order to perform program in any other block, and then resum ed. Program can be suspended to read data in any other block and then resumed. Each block can be programmed and erased over 100,000 cycles using the supply voltage V
.
Program and Erase command s are written to the Command Interface of the memory. An internal Program/Erase Controller takes care of the tim­ings necessary for program and erase operations.
The end of a program or erase operation can be detected and any error conditions identified in t he Status Register. The command set required to control the memory is consistent with JEDEC stan­dards.
The device supports synchronous burst read and asynchronous read from all blocks of the memory array; at power-up the device is configured for asynchronous read. In synchronous burst mode, data is output on each clock cycle at frequencies of up to 54MHz.
The M58CR064 features an instant, individual block locking scheme that allo ws any block to be locked or unlocked with no latency, enabling in­stant code and data protection. All blocks have three levels of protection. They can be locked and locked-down individually preventing any acciden­tal programming or erasure. In M58CR064C and M58CR064D there is an additional hardware pro­tection against program and erase. When V V
all blocks are protected against program or
PPLK
erase. All blocks ar e loc ke d at Power - Up. The device includes a Protection Register and a
Security Block to increase the protec tion of a s ys-
tem’s design. The Protection Register is divided into two segments: a 64 bit segm ent containin g a unique device number written by ST, and a 128 bit segment One-Time-Programmable (OTP) by the user. The user programmable segment can be permanently protected. The Security Block, pa­rameter block 0, can be permanently protected by the user. Figure 5, shows the Security Block and Protection Register Memory Map.
The memory is offered in a TFBGA56, 6.5 x 10mm, 0.75 mm ball pitch package and is supplied with all the bits erased (set to ’1’).
PP
6/70
M58CR064C, M58CR064D, M58CR064P, M58CR064Q

Figure 2. Logic Diagram Table 1. Signal Names

A0-A21 Address Inputs
A0-A21
W
RP
WP
DQ0-DQ15
V
V
DDQVPP
DD
22
16
DQ0-DQ15
E
WAIT
M58CR064C
G
M58CR064D M58CR064P
E G W RP WP KClock L
Data Input/Outputs, Command Inputs
Chip Enable Output Enable Write Enable Reset/Power-Down Write Protect
Latch Enable
M58CR064Q
WAIT V
V
V
V V
DD
DDQ
PP
SS
SSQ
L
K
V
SS
V
SSQ
AI90000
Wait Supply Voltage Supply Voltage for Input/Output
Buffers Optional Supply Voltage for
Fast Program & Erase Ground Ground Input/Output Supply
NC Not Connected Internally
7/70
M58CR064C, M58CR064D, M58CR064P, M58CR064Q

Figure 3. TFBGA Connections (Top view through package)

87654321
A
B
C A2
D A1
E
F
G
A13
A15
V
DDQ
V
SS
DQ7 V
A8A11
A9A12
A10
A14 WAIT A16 WP
DQ15
DQ14 DQ11 DQ10 DQ9 DQ0 G
SSQ
V
SS
A20
A21
DQ6
DQ13
DQ5 V
V
DD
K RP
L W
DQ4 DQ2 E A0
DD
V
PP
DQ12
DQ3
A18
DQ1
V
DDQ
A6
A5A17
A7A19
NC
DQ8
V
A4
A3
SSQ

Table 2. Bank Architecture

Bank A 16 Mbit 8 blocks of 4 KWord 31 blocks of 32 KWord Bank B 48 Mbit - 96 blocks of 32 KWord
8/70
AI90001
Bank Size Parameter Blocks Main Blocks

Figure 4. Me m ory Map

M58CR064C, M58CR064D, M58CR064P, M58CR064Q
Bank B
Bank A
000000h
007FFFh
2F8000h
2FFFFFh
300000h
307FFFh
3F0000h
3F7FFFh
3F8000h
3F8FFFh
3FF000h
3FFFFFh
Top Boot Block
Address lines A21-A0
512 Kbit or
32 KWord
512 Kbit or
32 KWord
512 Kbit or
32 KWord
512 Kbit or
32 KWord
64 Kbit or
4 KWord
64 Kbit or
4 KWord
Total of 96 Main Blocks (bottom bank)
Total of 31 Main Blocks (top bank)
Total of 8 Parameter Blocks (top bank)
Bank A
Bank B
000000h
000FFFh
007000h
007FFFh
008000h
00FFFFh
0F8000h
0FFFFFh
100000h
107FFFh
3F8000h
3FFFFFh
Bottom Boot Block
Address lines A21-A0
64 Kbit or
4 KWord
Total of 8 Parameter Blocks (bottom bank)
64 Kbit or
4 KWord
512 Kbit or
32 KWord
Total of 31 Main Blocks (bottom bank)
512 Kbit or
32 KWord
512 Kbit or
32 KWord
Total of 96 Main Blocks (top bank)
512 Kbit or
32 KWord
AI90002
9/70
M58CR064C, M58CR064D, M58CR064P, M58CR064Q

SIGNAL DESCRIPTIONS

See Figure 2 Logic Diagram and Table 1,Signal Names, for a brief overview of the signals connect­ed to this device.

Address Inputs (A0-A21). The Address Inputs select the cells i n the memory array to a ccess dur­ing Bus Read operations. During Bus Write opera­tions they control the commands sent to the Command Interface of the internal state machine.

Data Input/Output (DQ0-DQ15). The Data I/O outputs the data stored at the selected address during a Bus Read operation or inputs a command or the data to be programmed during a Bus Write operation.

Chip Enable (E
). The Chip Enable input acti-
vates the memory control logic, input buffers, de­coders and sense amplifiers. When Chip Enable is
and Reset/Power-Down is at VIH the device
at V
IL
is in active mode. When Chip Enable is at V
IH
the memory is deselected, the outputs are high imped­ance and the power consumption is reduced to the stand-b y l e vel .
Output Enable (G
). The Output Enable controls
the outputs during the Bus Read operation of the memory .
Write Enable (W
). The Write Enable controls the
Bus Write operation of the memory’s Command Interface. The data and address inputs are latched on the rising edge of Chip Enable or Write Enable whichever occurs first.
Write Protect (WP
). Write Protect is an input
that gives an additional hardware protection for each block. When Write Protect is at V
, the Loc k-
IL
Down is enabled and the prote ction status of t he Locked-Down blocks cannot be changed. When Write Protect is at V
, the Lock-Down is disabled
IH
and the Locked-Down blocks can be locked or un­locked. (refer to Table 13, Lock Status).
Reset/Power-Down (RP
). The Reset/Power-
Down input provides a hardware reset of the mem­ory, and/or Power-Down functions, depending on the Configuration Register status. When Reset/ Power-Down is at V
, the memory is in reset
IL
mode: the outputs are hi gh impedance an d if the Power-Down function is enabled t he current con­sumption is reduced to the Reset Supply Current I
. Refer to Table 18, DC Characte ristics - Cur-
DD2
rents for the value of I
After Reset all blocks
DD2.
are in the Locked state and the Configuration Reg­ister is reset. When Reset/Power-Down is at V
IH
the device is in normal operation. Exiting reset mode the device enters asynchronous read mode, but a negative transition of Chip Enable or Latch Enable is required to ensure valid data outputs.
The Reset/Power-Down pin can be interfaced with 3V logic without any additional circuitry. It can be
tied to V tics).
Latch Enable (L
dress bits on its rising edge. The a ddress latch is transparent when Latch Enable is at V hibited when Latch Enable is at V can be kept Low (also at board level) when the Latch Enable function is not required or supported.

Clo c k (K). The clock input synchronizes the memory to the microcontroller during synchronous read operations; the address is latched on a Clock edge (rising or falling, according to the configura­tion settings) when Latch Enable is at V don't care during asynchronous read and in write operations.

Wait (WAIT
synchronous read to indicate whether the dat a on the output bus are valid. This output is high imped­ance when Chip Enable or Output Enable are at V
or Reset/Power-Down is at VIL. It can be con-
IH
figured to be active during the wait cycle or one clock cycle in advance.
Supply Voltage. VDD provides the power
V
DD
supply to the internal core of the memory device. It is the main power supply for all operations (Read, Program and Erase).
Supply Voltage. V
V
DDQ
supply to the I/O pins and enables all Outputs to be powered independently from V tied to V
Program Supply Vol t age . VPP is both a
V
PP
control input and a power supply pin. In M58CR064C/D the two functions are s elected by the voltage range applied to the pin. In the M58CR064P/Q the control feature is disabled.
In M58CR064C/D if V range (0V to V In this case a voltage lower than V absolute protection against program or erase, while V bles 18 and 19, DC Characteristics for the relevant values). V program or erase; a change in its value after the operation has started does not have any effect and program or erase operations continue.
If V
is in the rang e of V
PP
supply pin. In this condition V til the Program/Erase algorithm is completed.
,
V
Ground. VSS ground is the reference for t he
SS
core supply. It must be connected to the system ground.
Ground. V
V
SSQ
the input/output circuitry driven by V must be connected to V
(refer to Table 19, DC Characteris-
RPH
). Latch Enable latches the ad-
IL
. Latch Enable
IH
). Wait is an output signal used during
provides the power
DDQ
. V
or can use a separate supply.
is kept in a low voltage
PP
) VPP is seen as a control input.
DDQ
PP
> V
enables these functions (see Ta-
PP1
is only sampled at the beginning of a
PP
it acts as a power
PPH
must be stable un-
PP
ground is the reference for
SSQ
SS
DDQ
PPLK
DDQ
and it is in-
. Clock is
IL
can be
gives an
. V
SSQ
10/70
M58CR064C, M58CR064D, M58CR064P, M58CR064Q
Note: Each device in a system should have V
DD, VDDQ
and VPP decoupled wi th a 0.1 µF ce-
ramic capacitor close to the pin (high frequen­cy, inherently low inductance capacitors should be as close as possible to the pack-

BUS OPERATIONS

There are six standard bus operations that control the device. These are Bus Read , Bus Write, Ad­dress Latch, Output Disable, Standby and Reset. See Table 3, Bus Operations, for a summary.
Typically glitches of less than 5ns on Chip Enable or Write Enable are ignored by the memory and do not affect Bus Write operations.

Bus Read. Bus Read operations are used to out­put the contents of the Memory Array, the Elec­tronic Signature, the Status Register and the Common Flash Interface. Both Chip Enable and Output Enable must be at V

in order to perform a
IL
read operation. The Chip Enable input s hould be used to enable the device. Out put Enable should be used to gate data onto the output. The data read depends on the previous command written to the memory (see Command Interface section). Refer to the Read AC Waveform figures and Char­acteristics tables in the DC and AC Parameters section for details of when the output becomes val­id.

Bus Write. Bus Write operations write Com­mands to the memory or latch Input Data to be programmed. A bus write operation is initiated when Chip Enable and Write Enable are at V Output Enable at V

. Commands, Input Data and
IH
IL
with
Addresses are latched on the rising edge of Write Enable or Chip Enable, whichever occurs first. The addresses can also be latched prior to the write operation by toggling Latc h Enable. In this case
age). See Figure 9, AC Measurement Load Cir­cuit. The PCB track widths should be sufficient to carry the re quired V
program and erase
PP
currents.
the Latch Enable shoul d be t ied to V
during the
IH
bus write operation. See Figures 14 and 15, Write AC Waveforms, and
Tables 22 and 23, Write AC Characteristics, for details of the timing requirements.

Address Latch. Address latch operations input valid addresses. Both Chip enable and Latch En­able must be at V

during address latch opera-
IL
tions. The addresses are latched on the rising edge of Latch Enable.

Output Disa bl e . The outputs are high imped­ance when the Output Enable is at V

.
IH

Standby. Standby di sables most of the internal circuitry allowing a substantial reduction of the cur­rent consumption. The memory is in stand-by when Chip Enable and Reset/Power-Down a re at

. The power consumption is reduced to the
V
IH
stand-by level and the ou tputs are se t to high im­pedance, independently from the Output Enable or Write Enable inputs. If Chip Enable switches to V
during a program or erase operation, t he de-
IH

vice enters Standby mode when finished. Reset. During Reset mode the memory is dese-

lected and the outputs are high impedance. The memory is in Reset mode when Reset/Power­Down is at V
. The power consumption is reduced
IL
to the Standby leve l, inde pendent ly from t he Chip Enable, Output Enable or Write Enable inputs. If Reset is pulled to V
during a Program or Erase,
SS
this operation is aborted and the mem ory content is no longer valid.

Table 3. Bus Operations

Operation E G W L RP WAIT DQ15-DQ0
Bus Read Bus Write Address Latch
Output Disable Standby Reset X X X X
Note: 1. X = Don’t care.
2. L
can be tied to VIH if the valid address has been previo usly latched.
3. Depends on G
V
IL
V
IL
V
IL
V
IL
V
IH
.
V
IL
V
IH
X
V
IH
XXX
V
IH
V
IL V
V
IH
V
IH
(2)
V
IL
(2)
IL
V
IL
X
V
IH
V
IH
V
IH
V
IH
V
IH
V
IL
Hi-Z Data Input
Data Output or Hi-Z Hi-Z Hi-Z Hi-Z Hi-Z Hi-Z Hi-Z
Data Output
(3)
11/70
M58CR064C, M58CR064D, M58CR064P, M58CR064Q

COMMAND INTERFACE

All Bus Write operations t o the me mory are in ter­preted by the Command Interface. Commands consist of one or more sequential Bus Write oper­ations. An internal Program/Erase Controller han­dles all timings and verifies the correct execution of the Program and Erase commands. The Pro­gram/Erase Controller provides a S tatus Register whose output may be read at any ti me to monitor the progress or the result of the operation.
The Command Interface is reset to read mode when power is first applied, when exiting from Re­set or whenever V
is lower than V
LKO
. Com­mand sequences must be followed exactly. Any invalid combination of commands will reset the de­vice to read mode.
Refer to Table 4, Command Codes and Appendix D, Tables 36 and 37, Command Interface States ­Modify and Lock Tables, for a summary of the Command Interface.
The Command Interface is split into two type s of commands: Standard commands and Factory Program commands. The following sections ex­plain in detail how to perform each command.

Table 4. Command C odes

Hex Code Command
01h Block Lock Confirm 03h Set Configuration Register Confirm 10h Alternative Program Setup 20h Block Erase Setup 2Fh Block Lock-Down Confirm 30h Double Word Program Setup 40h Program Setup 50h Clear Status Register 55h Quadruple Word Program Setup
60h
70h Read Status Register 80h Bank Erase Setup 90h Read Electronic Signature
Block Lock Setup, Block Unlock Setup, Block Lock Down Setup and Set Configuration Register Setup
98h Read CFI Query B0h Program/Erase Suspend C0h Protection Register Program
D0h
FFh Read Array
Program/Erase Resume, Block Erase Confirm, Bank Erase Confirm, Block Unlock Confirm
12/70
M58CR064C, M58CR064D, M58CR064P, M58CR064Q

COMMAND INTERFACE - STANDARD COMMANDS

The following commands are the basic commands used to read, write to and configure the device. Refer to Table 5, Standard Commands, in con­junction with the following text descriptions.

Read Array Command

The Read Array comm and returns the addressed bank to Read Array mode. One Bus Write cycle is required to issue the Read Array command and re­turn the addressed bank to Read Array mode. Subsequent read operations will read the ad­dressed location and output t he data. A Read Ar­ray command can be issued in one bank while programming or erasing in the other bank. Howev­er if a Read Array co mmand is issued to a bank currently executing a Program or Erase operation the command will be ignore d.

Read Status Register Command

A Bank’s Status Register indicates when a Pro­gram or Erase operation is complete and t he suc ­cess or failure of operation itself. Issue a Read Status Register command to read the Status Reg­ister content of the addressed Bank. The Read Status Register comma nd can be issued at any time, even during Program or Erase operations.
The following Bus Read operations output the con­tent of the Status Register of the addressed bank. The Status Register is latched on the falling edge
or G signals, and can be read until E or G re-
of E turns to V date the latched data. See Table 8 for the description of the Status Register Bit s. This m ode supports asynchronous or single synchronous reads only.

Read Electronic Signature Command

The Read Electronic Signature command reads the Manufacturer and Device Codes, the Block Locking Status, the Protection Register, and the Configuration Register.
The Read Electronic Signature command consists of one write cycle to an address within the bot tom bank. A subsequent read operation in the address of the bottom bank will output the Manufacturer Code, the Device Code, the protection Status of Blocks of the bottom bank, the Die Revision Code, the Protection Register, or the Read Configuration Register (see Table 6).
If the first write cycle of Read Electronic Signature command is issued t o an address within the top bank, a subsequent read operat ion in an address of the top bank will output the protection Statu s of blocks of the top bank. The status of the other bank is not affected by the command (see Tab le
11). This mode supports asynchronous or sing le synchronous reads only, it do es not support page mode or synchronous burst reads.
. Either E or G must be toggled to up-
IH

Read CFI Query Command

The Read CFI Query command is used to read data from the Common Flash Interface (CFI) memory area located in the bottom bank. The Read CFI Query Command consists of one Bus Write cycle, to an address within the bottom bank. Once the command is issued subsequent Bus Read operations in the s ame bank read from the Common Flash Interface.
If a Read CFI Query command is issued in a bank that is executing a Program or Erase operation the bank will go into Read Status Register mode, sub­sequent Bus Read cycles will output the Status Register and the Program/Erase controller will continue to Program or Erase in t he background. When the Program or Erase operation has fin­ished the device will enter Read CFI Query mode.
This mode supports asynchronous or single syn­chronous reads only, it does not support page mode or synchronous burst reads.
The status of the other banks is not affected by the command (see Table 11). After issuing a Read CFI Query command, a Read Array command should be issued to t he address ed bank to return the bank to read mode.
See Appendix B, Common Flash Interface, Tables 30, 31, 32, 33, 34 and 35 for details on the in for­mation contained in the Co mmon Flash Interface memory area.

Clear Status Register Command

The Clear Status Register comm and c an b e us ed to reset (set to ‘0’) error bits SR1, SR3, SR4 and SR5 in the Status Register of the addressed bank. One bus write cycle is required to issue the Clear Status Register command. After the Clear S tatus Register command the bank returns to Read Array mode.
The error bits in the Status Regi ster do not auto­matically return to ‘0’ when a new command is is­sued. The error bits i n the Stat us Register should be cleared before attempting a new Program or Erase command.

Block Erase Command

The Block Erase com mand can be used to erase a block. It sets all the bits within the selected block to ’1’. All previous d ata in th e block is lost. If th e block is protected then the Erase operation will abort, the data in the block will not be changed and the Status Register will output the error. The Block Erase command can be issued at any moment, re­gardless of whether the block has been pro­grammed or not.
Two Bus Write cycles are required to issue the command.
The first bus cycle sets up the Erase command.
13/70
M58CR064C, M58CR064D, M58CR064P, M58CR064Q
The second latches the block address in the
internal state machine and starts the Program/ Erase Controller.
If the second bus cycle is not Write Erase Confirm (D0h), Status Register bits SR 4 and SR5 are set and the command aborts. Erase aborts if Reset turns to V
. As data integrity cannot be guaran-
IL
teed when the Erase operation is aborted, the block must be erased again.
Once the command is issued the device outputs the Status Register data when any address within the bank is read. At the end o f the operation the bank will remain in Read Status Register mode un­til a Read A rray, Read CFI Query o r Read Elec­tronic Signature command is issued.
During Erase operations the bank containing the block being erased will onl y ac cept the Read Sta­tus Register and the Program/Erase Suspend command, all other commands will be ignored. Refer to Dual Operations section for detailed infor­mation about simultaneous operations allowed in banks not being erased. Typical Erase times are given in Table 14, Program, Erase Times and Pro­gram/Erase Endurance Cycles.
See Appendix C, Figure 24, Block Erase Flow­chart and Pseudo Code, for a suggested flowchart for using the Block Erase command.

Program Command

The memory array can be programmed word-by­word. Only one Word in one bank can be pro­grammed at any one time. Two bus write cycles are required to issue the Program Command.
The first bus cycle sets up the Program
command.
The second latches the Address and the Data to
be written and starts the Program/Erase Controller.
After programming has started, read operations in the bank being programmed output the Status Register content.
During Program operations the bank being pro­grammed will only accept the Read Statu s Regis­ter and the Program/Erase Suspend command. Refer to Dual Operations section for detailed infor­mation about simultaneous operations allowed in banks not being programmed. Typical Program times are given in Table 14, Program, Erase Times and Program/Erase Endurance Cycles.
Programming aborts if Reset goe s to V
. As data
IL
integrity cannot be guaranteed when the program operation is aborted, the memory location must be reprogrammed.
See Appendix C, Figure 20, Program Flowchart and Pseudo Code, for the f lowchart for using the Program command.

Program/Erase Suspend Command

The Program/Erase Suspend command is used to pause a Program or Block Erase operation. A Bank Erase operation cannot be suspended.
One bus write cycle is required to issue t he Pro­gram/Erase Suspend command. Once the Pro­gram/Erase Controller has paused bits SR7 , SR6 and/ or SR2 of the Status Register will be set to ‘1’.
The command must be addressed to the bank containing the Program or Erase operation.
During Program/Erase Suspend the Command In­terface will accept the Program/Erase Resume, Read Array (cannot read the suspended block), Read Status Register, Read Electronic S ignature and Read CFI Q uery commands. Additionally, if the suspend operation was Erase then the Clear status Register, Program, Block Lock, Block Lock­Down or Protection Program commands wi ll also be accepted. The block being erased may be pro­tected by issuing the Block Lock, Block Lock­Down or Protection Register Program commands. Only the blocks not being e rased m ay be read or programmed correctly. When the Program /Erase Resume command is issued the operation will complete. Refer to the Dual Operations section for detailed information about simultaneous opera­tions allowed during Program/Erase Suspend.
During a Program/Erase Suspend, the device can be placed in standby mode by taking Chip Enable
. Program/Erase is aborted if Reset turns to
to V
IH
V
.
IL
See Appendix C, Figure 23 , Program Suspend & Resume Flowchart and Pseudo Code, and Figure 25, Erase Suspend & Resume Flowchart and Pseudo Code for flowcharts for using the Program/ Erase Suspend command.

Program/Erase Resu me Command

The Program/Erase Resume command can be used to restart the Program/Erase Controller after a Program/Erase Suspen d command has paused it. One Bus Write cycle is required to issue the command. The comm and must be written to the bank containing the Program or Erase Suspend.
The Program/Erase Resume command changes the read mode of th e target bank to Read S tatus Register mode.
If a Program command is iss ued during a Block Erase Suspend, then the erase cannot be re­sumed until the programming operation has com­pleted. It is possible to accumulate suspend operations. For example: su spend an erase oper­ation, start a programming operation, suspend the programming operation then read the array. See Appendix C, Figure 23, Program Su spend & Re­sume Flowchart and Pseudo Code, and Figure 25, Erase Suspend & Resume Flowchart and Pseudo
14/70
M58CR064C, M58CR064D, M58CR064P, M58CR064Q
Code for flowcharts for using the Program/Erase Resume command.

Protection Regi ster Pr ogram Com m and

The Protection Register Program command is used to Program the 128 bit user O ne-Time-Pro­grammable (OTP) segment of the Protection Reg­ister. The segment is programmed 16 bits at a time. When shipped all bits in the segment are set
to ‘1’. The user can only program the bits to ‘0’. Two write cycles are required to issue the Protec-
tion Register Program command.
The first bus cycle sets up the Protection
Register Program command.
The second latches the Address and the Data to
be written to the Protection Register and starts the Program/Erase Controller.
Read operations output the Status Register con­tent after the programming has started.
The segment can be protected by programming bit 1 of the Protection Lock Register. Bit 1 of the Pro­tection Lock Register also protects bit 2 of the Pro­tection Lock Register. Programming bit 2 of the Protection Lock Register will result in a permanent protection of Parameter Block #0 (see Figure 5, Security Block and Protection Register Memory Map). Attempting to program a previously protect­ed Protection Register will result in a Status Reg­ister error. The protection of the Protection Register and/or the Security Block is not revers­ible.
The Protection Register Program cannot be sus­pended. See Appendix C, Figure 27, Protection Register Program Flowchart and Pseudo Code, for a flowchart for using the Protection Register Program command.

Set Conf ig uration Regi s te r C om m and.

The Set Configuration Register command is used to write a new value to the Configuration Control Register which defines the burst length, type, X la­tency, Synchronous/Asynchronous Read mode and the valid Clock edge configuration.
Two Bus Writ e cycles a re required to i ssue the Set Configuration Register command.
The first cycle writes the setup command and
the address corresponding to the Configuration Register content.
The second cycle writes the Configuration
Register data and the confirm command.
Once the comman d is issued the memory ret urns to Read mode.
The value for the Configuration Register is always presented on A0-A15. CR0 is on A0, CR1 on A1, etc.; the other address bits are ignored.

Block Lock Command

The Block Lock command is used to lock a block and prevent Program or Erase operations from changing the data in it. All blocks are locked at power-up or reset.
Two Bus Write cycles are required to issue the Block Lock command.
The first bus cycle sets up the Block Lock
command.
The second Bus Write cycle latc hes the block
address.
The lock status can be monitored for each block using the Read Electronic Signature command. Table. 13 shows the Lock Status after issuing a Block Lock command.
The Block Lock bits are vo latile, once set they re­main set until a hardware reset or power-down/ power-up. They are cleared by a Block Unlock command. Refer to the section, Block Locking, for a detailed explanation. See Appendix C, Figure 26, Locking Operations Flowchart and Pseudo Code, for a flowchart for using the Lock command.

Block Unlock Command

The Block Unlock command is used to unlock a block, allowing the block to be programmed or erased. Two Bus Write cycles are requ ired to is­sue the Block Unlock command.
The first bus cycle sets up the Block Unlock
command.
The second Bus Write cycle latc hes the block
address.
The lock status can be monitored for each block using the Read Electronic Signature command. Table 13 shows the protection status after issuing a Block Unlock command. Refer to the section, Block Locking, for a detailed expla nation and A p­pendix C, Figure 26, Locking Operations Flow­chart and Pseudo Code, f or a flowchart for using the Unlock command.

Block Lock-Down Command

A locked or unlocked block can be locked-down by issuing the Block Lock-Down command. A locked­down block cannot be programm ed or erased, or have its protection status changed when WP low, V
. When WP is high, V
IL
the Lock-Down
IH,
is
function is disabled and the locked blocks can be individually unlocked by the Block Unlock com­mand.
Two Bus Write cycles are required to issue the Block Lock-Down command.
The first bus cycle sets up the Block Lock
command.
The second Bus Write cycle latc hes the block
address.
15/70
M58CR064C, M58CR064D, M58CR064P, M58CR064Q
The lock status can be monitored for each block using the Read Electronic Signature command. Locked-Down blocks revert to the locked (and not locked-down) state when the device is reset on power-down. Table. 13 shows the Lo ck Statu s af-
ter issuing a Block Lock-Down command. Refer to the section, Block Locking, for a detailed explana­tion and Appendix C, Fi gure 26, Locking Opera­tions Flowchart and Pseudo Code, for a flowchart for using the Lock-Down command.

Table 5. Standard Commands

Bus Operations
Commands
Cycles
Read Array 1+ Write BKA FFh Read Status Regist er 1+ Write BKA 70h Read
Read Electronic Signature 1+ Write
Read CFI Query 1+ Write BBKA 98h Read Clear Status Register 1 Write BKA 50h Block Erase 2 Write B KA 20h Write BA D0h
Program 2 Write BKA 40h or 10h Write WA PD Program/E rase Su s pen d 1 Wr i te BKA B0h Program/Erase Resume 1 Write BKA D0h Protection Register Program 2 Write PRA C0h Write Set Configuration Register 2 Write CRD 60h Write Block Lock 2 Write BKA 60h Write Block Unlock 2 Write BKA 60h Write Block Lock-Down 2 Write BKA 60h Write
Note: 1. X = Don’t Care, WA=Word Address in targeted bank, RD=Read Data, SRD=Status Register Data, ESD=Electronic Signature Data,
QD=Query Data, BA=Block Address, BKA= Bank Address, BBKA= Bottom Bank Address, PD=Program Data, PRA=Protection Register Address, PRD=Protection Register Data, CRD=Configuration Register Data.
2. Must be same bank as in the first cycle. The signature address es are listed i n T able 6.
3. When addre ss ed to a block i n th e T op Bank, re ads Block Prot ection data only.
Op. Add Data Op. Add Data
1st Cycle 2nd Cycle
BBKA or
(3)
BKA
Read
90h Read
WA RD
(2)
BKA
BBKA or
(2,3)
BKA
(2)
BBKA
PRA PRD CRD
BA 01h BA D0h BA
SRD
ESD
QD
03h
2Fh
(3)
16/70
M58CR064C, M58CR064D, M58CR064P, M58CR064Q

Table 6. Electronic Signature Codes

Code Address (h) Data (h)
Manufacturer Code Bottom Bank Address + 00 0020
Top (M58CR064C)
88CA
Bottom (M58CR064D) 88CB
Device Code
Bottom Bank Address + 01
Top (M58CR064P) 8801 Bottom (M58CR064Q) 8802 Lock
0001
Unlocked 0000
Block Protection
Block Address + 02
Locked and Locked-Down 0003
Unlocked and Locked-Down 0002 Reserved Bottom Bank Address + 03 Reserved Configuration Register Bottom Bank Address + 05 CR
ST Factory Default
xx06
Security Block Permanently Locked xx02 Protection Register Lock
OTP Area Permanently Locked xx04
Security Block and OTP Area Permanently
Locked
Bottom Bank Address + 80
Bottom Bank Address + 81 Bottom Bank Address + 84
xx00
Unique Device
Number
Protection Register
Bottom Bank Address + 85 Bottom Bank Address + 8C
Note: CR=Conf ig uration Regi ster.
OTP Area

Figure 5. Security Block and Protection Register Memory Map

PROTECTION REGISTER
8Ch
SECURITY BLOCK
85h 84h
Parameter Block # 0
81h 80h
User Programmable OTP
Unique device number
Protection Register Lock 2 1 0
AI06181
17/70
M58CR064C, M58CR064D, M58CR064P, M58CR064Q

COMMAND INTERFACE - FACTORY PROGRAM COMMANDS

The Factory Program commands are used to speed up programming. They require V V
except for the Bank Eras e command which
PPH
also operates at V
= VDD. Refer to Table 7, Fac-
PP
to be at
PP
tory Program Commands, in conjunction with the following text descriptions.

Bank Erase Command

The Bank Erase command can be used to erase a bank. It sets all the bits within the selected bank to
’1’. All previous data in th e ban k is lo st. Th e B ank Erase command will igno re any protected blocks within the bank. If all blocks in the ba nk are pro­tected then the Bank Erase operation will abort and the data in the bank wi ll not b e changed. The Status Register will not output any error.
Bank Erase operations can be p erformed at both
= V
V
PP
and VPP = VDD.
PPH
Two Bus Write cycles are required to issue the command.
The first bus cycle sets up the Bank Erase
command.
The second latches the bank address in the
internal state machine and starts the Program/ Erase Controller.
If the second bus cycle is not Write Bank Erase Confirm (D0h), Status Register bits SR4 and S R5 are set and the command aborts. Erase aborts if Reset turns to V
. As data integrity cannot be
IL
guaranteed when the Erase operation is aborted, the bank must be erased again.
Once the command is issued the device outputs the Status Register data when any address within the bank is read. At the end o f the operation the bank will remain in Read Status Register mode un­til a Read Array, Read CFI Query or Read Elec­tronic Signature command is issued.
During Bank Erase operations the bank being erased will only accept the Read Status Regi ster command, all other commands w ill be ignored . A Bank Erase operation cannot be suspended.
For optimum performance, Bank Erase com­mands should be limited to a maximum of 100 Pro­gram/Erase cycles per Block. After 100 Program/ Erase cycles the internal algorithm will still operate properly but some degradation in performance may occur.
Dual operations are not supported during Bank Erase operations and the command cannot be suspended.
Typical Erase times are given in Table 14, Pro­gram, Erase Times and Program/Erase Endur­ance Cycles.

Double Word Program Command

The Double Word Program command improves the programming throughput by writing a page of two adjacent words in parallel. The two words must differ only for the address A0.
Programming should not be attempted when V is not at V V
is below V
PP
Three bus write cycles are necessary to issue the Double Word Program command.
The first bus cycle sets up the Double Word
Program Command.
The second bus cycle latches the Address and
the Data of the first word to be written.
The third bus cycle latches the Address and the
Data of the second word to be written and starts the Program/Erase Controller.
Read operations in the bank bei ng programmed output the Status Register content after the pro­gramming has started.
During Double Word Program operations the bank being programmed will only a ccept the Read Sta­tus Register command, all other commands will be ignored. Dual operations are not supported during Double Word Program operations. It is not recom­mended to suspend the Double Word Program command. Typical Program times are given in Ta­ble 14, Program, Erase Times and Program/Erase Endurance Cycles.
Programming aborts if Reset goe s to V integrity cannot be guaranteed when the program operation is aborted, the memory locations m ust be reprogrammed.
See Appendix C, Figure 21, Double Word Pro­gram Flowchart and Pseudo Code, for the flow­chart for using the Double Word Program command.

Quadruple Word Program Command

The Quadruple Word Program command im­proves the programming throughput by writing a page of four adjacent words in parallel. The four words must differ only for the addresses A0 and A1.
Programming should not be attempted when V is not at V
is below V
V
PP
Five bus write cycles are necessary to issue the Quadruple Word Program command.
The first bus cycle sets up the Double Word
Program Command.
The second bus cycle latches the Address and
the Data of the first word to be written.
. The command can be executed if
PPH
PPH
but the result is not guaranteed.
PPH
IL
. The command can be executed if
but the result is not guaranteed.
PPH
PP
. As data
PP
18/70
M58CR064C, M58CR064D, M58CR064P, M58CR064Q
The third bus cycle latches the Address and the
Data of the second word to be written.
The fourth bus cycle latches the Address and
the Data of the third word to be written.
The fifth bus cycl e latches the Addr es s and the
Data of the fourth word to be written and starts the Program/Erase Controller.
Read operations to the bank being programmed output the Status Register content after the pro­gramming has started.
Programming aborts if Reset goe s to V
. As data
IL
integrity cannot be guaranteed when the program operation is aborted, the memory locations mu st be reprogrammed.
During Quadruple Word Program operations the bank being programmed will only accept the Read Status Register command, all other commands will be igno re d.
Dual operations are not supported during Quadru­ple Word Program operations. It is not recom­mended to suspend the Quadruple Word Program command. Typical Program times are given in Ta­ble 14, Program, Erase Times and Program/Erase Endurance Cycles.
See Appendix C, Figure 22, Quadruple Word Pro­gram Flowchart and Pseudo Code, for the flow­chart for using the Quadruple Word Program command.

Table 7. Factory Program Commands

Bus Write Operations
Command Phase
Cycles
Bank Eras e 2 BKA 80h BKA D0h
(2)
Double Wor d Program Quadruple Word
Program
Note: 1. WA=Word A dd ress in t arget ed bank, BKA= Bank A d dress, PD = P r ogram Data, WA1 is t h e S t a rt Addr e s s.
(3)
2. Word Addres ses 1 and 2 must be consecutive Addresses differing only for A0.
3. Word Addres ses 1,2,3 and 4 must be consecutive Addresses di ffering onl y for A0 and A1.
3 BKA 30h WA1 PD1 WA2 PD2
5 BKA 55h WA1 PD1 WA2 PD2 WA3 PD3 WA4 PD4
1st 2nd 3rd 4th 5th
Add Data Add Data Add Data Add Data Add Data
19/70
M58CR064C, M58CR064D, M58CR064P, M58CR064Q

STATUS REGISTER

The M58CR064 has two Status Registers, one for each bank. The Status Registers provide informa­tion on the current or previous Program or Erase operations executed in each bank. Issue a Read Status Register command to read the contents of the Status Register, refer to Read Status Register Command section for more details. To output the contents, the Status Register is latched and updat­ed on the falling edge of the Chip Enable or Output Enable signals, and can be read until Chip Enable or Ou tpu t Enable return s to V
. The Status Reg-
IH
ister can only be read using single asynchronous or single synchronous reads. Bus Read opera­tions from any address within the bank, always read the Status Register during Program and Erase operations.
The various bits convey information about the sta­tus and any errors of the operation. Bits SR7, SR6 and SR2 give information on the status of the bank and are set and reset by the device. Bits SR5, SR4, SR3 and SR1 give information on errors, they are set by the device but must be reset by is­suing a Clear Status Register command or a hard-
ware reset. If an error bit is set to ‘1’ the Status Register should be reset before issuing another command.
The bits in the Status Register are summarized in Table 8, Status Register Bits. Refer to Table 8 in conjunction with the following text descriptions.
Program/Erase Controller Status Bit (SR7). The Program/Erase Controller Status bit indicates whether the Program/Erase Controller is act ive or inactive in the addressed bank. When the Pro­gram/Erase Controller Status bit is Low (set to ‘0’), the Program/Erase Controller is active; when the bit is High (set to ‘1’), the Prog ram/E rase Cont rol­ler is inactive, and the device is ready to process a new command.
The Program/Erase Controller Status is Low im­mediately after a Program/Erase Suspend com­mand is issued until the Program/Erase Controller pauses. After the Program/Erase Controller paus­es the bit is High.
During Program, Erase, o perations the Program/ Erase Controller Status bit can be polled to find the end of the operation. Other bits in the Status Reg­ister should not be tested until the Program/Erase Controller completes the operation and the bit is High.
After the Program/Erase Cont roller completes its operation the Erase Status, Prog ram Status, V
PP
Status and Block Lock Status bits should be tested for errors.
Erase Suspend Status Bit (SR6). The Erase Suspend Status bit indicates that an Erase opera­tion has been suspended or is going to be sus-
pended in the addressed block. When the Eras e Suspend Status bit is High (set to ‘1’), a Program/ Erase Suspend command has been issued and the memory is waiting for a Program/Erase Re­sume command.
The Erase Suspend Status should only be consid­ered valid when the Program/Erase Controller Sta­tus bit is High (Program/Erase Controller inactive). SR7 is set within 30µs of the Program/Erase Sus­pend command being issued therefore the memo­ry may still complete the operation rather than entering the Suspend mode.
When a Program/Erase Re sume command is is­sued the Erase Suspend Status bit returns Low.
Erase Status Bit (SR5). The Erase Status bit can be used to identify if the memory has failed to verify that the block or bank has erased correctly. When the Erase Status b it is High (set to ‘1’), the Program/Erase Controller has applied the maxi­mum number of pulses to the block or bank and still failed to verify that it has erased correctly. The Erase Status bit should be read once the Program/ Erase Controller Status bit is High (Program/Erase Controller inactive).
Once set High, the Erase Status bit can only be re­set Low by a Clear Status Register command or a hardware reset. If set High it should be reset be­fore a new Program or Erase command is issued, otherwise the new command will appear to fail.
Program Status Bit (SR4). The Program Status bit is used to identify a Pr ogram failure. When the Program Status bit is High (set to ‘1’), the Pro­gram/Erase Controller has applied the maximum number of pulses to the byte and still failed to ver­ify that it has programmed correctly. The Program Status bit should be read once the Program/Erase Controller Status bit is High (Program/Erase Con­troller inactive).
Once set High, the Program Status bit can only be reset Low by a Clear Status Register command or a hardware reset. If set High it should be reset be­fore a new command is issued, otherwise the new command will appear to fail.
Status Bit (SR3). The VPP Status bit can be
V
PP
used to identify an invalid v oltage on the V during Program and Erase operations. The V pin is only sampled at the beginning of a Program or Erase operation. Indeterminate results can oc­cur if V
When the V age on the V when the V pin has a voltage that is below the VPP Lockout Voltage, V gram and Erase operations cannot be performed.
becomes invalid during an operation.
PP
Status bit is Low (set to ‘0’), the volt-
PP
pin was sampled at a valid voltage;
PP
Status bit is High (set to ‘1’), the V
PP
, the memory is protected and Pro-
PPLK
PP
pin
PP
PP
20/70
M58CR064C, M58CR064D, M58CR064P, M58CR064Q
Once set High, the VPP Status bit can only be reset Low by a Clear Status Register command or a hardware reset. If set High it should be reset be­fore a new Program or Erase command is issued, otherwise the new command will appear to fail.
Program Suspend Status Bit (SR2). The Pro­gram Suspend Status bit indicates that a Program operation has been suspended in the addressed block. When the Program Suspend Status bit is
High (set to ‘1’), a Program/Erase Suspend com­mand has been issued and the memory is waiting for a Program/Erase Resume command. The Pro­gram Suspend Status should only be considered valid when the Program/Erase Controller Status bit is High (Program/Erase Controller inactive). SR2 is set within 5µs of the Program/Erase Sus­pend command being issued therefore the memo-
When a Program/Erase Re sume command is is­sued the Program Suspend Status bit returns Low.
Block Protection Status Bit (SR1). The Block Protection Status bit can be used to identify if a Program or Block Erase operation has tried to modify the contents of a locked block.
When the Block Protection Status bit is High (set to ‘1’), a Program or Erase operation has been at­tempted on a locked block.
Once set High, the Block Protection Status bit can only be reset Low by a Clear Status Register com­mand or a hardware reset. If set High it should be reset before a new command is issued, otherwise the new command will appear to fail.
Reserved Bit (SR0). SR0 is reserved. Its value must be masked.
ry may still complete the operation rather than entering the Suspend mode.

Table 8. Status Register Bits

Bit Name Type Logic Level Definition
SR7 P/E.C. Status Status
SR6 Erase Suspend Status Status
SR5 Erase Status Error
’1’ Ready ’0’ Busy ’1’ Erase Suspended ’0’ Erase In progress or Completed ’1’ Erase Error ’0’ Erase Success
SR4 Program Status Error
Status
V
SR3
SR2 Program Suspend Status Status
SR1 Block Protection Status Error
SR0 Reserved
Note: Logic level ’1’ is High, ’0’ is Low.
PP
Error
’1’ Program Error ’0’ Program Success
V
’1’ ’0’ ’1’ Program Suspended ’0’ Program In Progress or Completed ’1’ Program/Erase on protected Block, Abort ’0’ No operation to protected blocks
Invalid, Abort
PP
OK
V
PP
21/70