SGS Thomson Microelectronics LDO-514 Datasheet

1/4June 2002
RF REGULATOR
VERY LOW DROPOUT VOLTAGE : 50mV
VERY LOW CONSUMPTION : 320µA FULL LOAD
VERY GOOD TRANSIENT BEHAVIOUR : 1mV
OUTPUT CURRENT : 200mA
HIGH PSRR : 65dB
NO CURRENT IN POWER DOWN MODE
SHORT CIRCUIT PROTECTION
TYPICAL APPLICATIONS
– Cellular and Cordless phones suppli ed by 1 cell
Lithium-ion battery / 3 cells Ni-MH or Ni-Cd
battery – PDA (Personal Digital Assistant), – Smart phone – Portable equipm ent – Supply for RF devices for cellular phone
APPLICATION NOTE
An external capacitor (C
OUT
= 1µF) with an
equivalent serial resistance (ESR) in the range
0.02 to 0.6Ω is used for regulator stability.
Figure 1 :
Block Diagram
?
V
REF
?
? ?
LDO_514
OUTIN
PWRDWN
STDBY
Figure 2 :
Typical Application Circuit
1µF
ESR
V
OUT
C
OUT
?
?
OUT
GND
?
?
?
V
IN
IN
PWRDWN
Power Down Mode
OFF
ON
Stand-by Mode
STDBY
Active Mode
LDO_514
→ →
Stand-by Mode
→ →
LDO_514
This is advance information on a new product now in development or undergoing evaluation. Details are subject to change without noti ce.
PRODUCT PREVIEW
IP Library: High PSRR, Very Low power,
200mA Low Dropout Volt age Regulator
LDO_514
2/4
ELECTRICAL CHARACTERISTICS
3V < V
IN
< 5.5V, -55°C < TA < +125°C, C
OUT
= 1µF ±20%, 20mΩ < ESR < 0.6Ω, I
LOAD
= 200mA.
Typical case : V
IN
= 4V, T = 25°C, C
OUT
= 1µF.
Notes: 1. Above characteristics are given for 3V minimum input operating range voltage, but regulator is
operational with 2.7V minimum input voltage.
2. All parameters are guaranteed with 170mV min Dropout voltage.
Parameter Symbol Test Condition Min. Typ. Max. Unit
Input Voltage Range (Note 1) V
IN
3 5.5 V
Output Voltage V
OUT
2.8 V Output Voltage Accuracy 3 % Output current I
OUT
200 mA
Dropout Voltage V
DO
V
OUT
= 50mV,
I
LOAD
= 200mA
50 mV
(Note 2) 170
Quiescent current I
Q
I
LOAD
= 100µA 70 110 µA
I
LOAD
= 20mA 90 130
I
LOAD
= 200mA 320 440
Power down mode quiescent current
I
QPDM
Power down active 100 nA
Power Supply Rejection Ratio PSRR DC 65 dB
f = 10KHz 60 f = 100KHz 50
Line Regulation L
IR
I
LOAD
= 200mA,
V
IN
= 3V to 5.5V
1.5 2.5 mV
Load Regulation L
DR
I
LOAD
= 100µA - 200mA 35 40 mV
Line Transient L
IRT
V
IN
= 300mV
t
RISE
= t
FALL
= 10µs
<1 mV
Load Transient L
DTR
I
LOAD
= 100µA - 200mA
in 10µs
0.5 1 mV
Output Noise Voltage en 100Hz 1400
1KHz 450 10KHz 150
en
RMS
BW : 100Hz to 100KHz 45 µV
RMS
Output decoupling Capacitor C
OUT
F
Settling time I
LOAD
= 200mA 15 30 µs
Short Circuit Current Limit I
SHORT
800 mA
nV
Hz
----------- -