FUNCTIONAL DIAGRAM
ABSOLUTE MAXI MU M RATINGS
Symbol Parame ter Val ue Unit
V
DD
* Supply Voltage :HC C Types
HCF Types
– 0.5to + 20
– 0.5to + 18
V
V
V
i
Input Voltage – 0.5 to VDD+ 0.5 V
I
I
DC Input Current (any one input) ± 10 mA
P
tot
Total Power Dissipation (per package)
Dissipation per Output Transistor
for T
op
= Full Package-temperature Range
200
100
mW
mW
T
op
Operating Temperature : HCC Types
HCF Types
–55to+125
–40to+85
°C
°C
T
stg
Storage Temperature – 65 to + 150 °C
RECOMMENDED OPERATING CONDITIONS
Symbol Parameter Value Unit
V
DD
Supply Voltage : HCC Types
HCF Types
3to18
3to15
V
V
V
I
Input Voltage 0 to V
DD
V
T
op
Operating Temperature : HCC Types
HCF Types
– 55 to + 125
–40to+85
°C
°C
Stresses above those listed under ”Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only
and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification
is not implied. Exposure to absolute maximum rating conditions for external periods may affect device reliability.
* All voltages are with respect to VSS(GND).
JAM inputs is asynchronously forced into the
counterregardless of the state of the SPE, CI/CE,
or CLOCK inputs. JAM inputsJO-J7 represent two
4-bit BCD words for the HCC/HCF40102B and a
single 8-bit binary word for the HCC/HCF40103B.
When the CLEAR (CLR) input is low, the counter
is asynchronously cleared to its maximum count
(9910for the HCC/HCF40102B and 25510for
theHCC/HCF40103B) regardless of the state of
any other input. The precedence relationship between control input is indicated in thetruth table. If
all control inputs are high atthetiemeofzerocount,
the counterswilljump to themaximum count, giving
a counting sequence of 100 or 256 clock pulses
long.TheHCC/HCF40102B andHCC/HCF40103B
may be cascaded using the CI/CE input and the
HCC/HCF40102B/40103B
2/13