SGS Thomson Microelectronics GS-MISTRAL Datasheet

FEATURES
LINE VOLTAGE 90 - 264 VAC SINGLE OUTPUT MAX 8W DESIGNED FOR ON LINE CHARGING OF
MOBILE PHONES EMC COMPLIANCE ACCORDING TO EU
AND US DIRECTIVES SAFETY APPROVAL ACCORDING TO
SOUTH AFRICA AND CHINA MARKING UPON REQUEST
OUTPUT CURRENT AND VOLTAGE LEVELS ACCORDING TO CUSTOMER REQUIRE­MENTS
OUTPUT VOLTAGE PRECISI O N: +/- 5% OUTPUT CURRENT PRECISION : +/- 12% OUTPUT RIPPLE VOLTAGE <100 mVpp INPUT FUSE PROTECTION OUTPUT SHORT CIRCUIT PROTECTION 2 WIRES DC CORD TERMINATED WITH
ANY CUSTOM CONNECTOR AVAILA BLE WI T H A VAR I ETY OF AC PL UGS
LOW STAND BY PO W ER
DESCRIPTION
The Fast Charger MISTRAL has been designe d for charging NiMH and NiCd batteries in hand held mobile phones. MISTRAL is a low cost high efficiency AC/DC switching mode constant volt­age & current generator. The output voltage and current levels are set up by design in accordance with customer requirements.
January 2000
®
PRODUCT VIEW
(Robin Housing, all plug types)
ORDERING NUMBER: GSAC-xxCCCy
MISTRAL
AC/DC Multirange FAST CH ARGE R
Rev. 01
Plug Type: Part Number:
EURO GSAC-xxCCC1
UK GSAC-xxCCC2 US GSAC-xxCCC3
AUSTRALIA GSAC-xxCCC4
INDIA/S. Africa GSAC-xxCCC5
CHINA GSAC-xxCCC6
xx = Output Current level (2 Digits) CCC= Customer Identifier (3 Digits) y = plug type
1/4
Typical reference values in this datasheet are 8V, 700 mA with the input Vac ranging from 90 to 264 Vrms.
Coming into the small Robin housing, MISTRAL can be assembled with a variety of AC plugs identified by specific ordering numbers. Interface to the phone is ensured via a 2 wires cord with strain relief, terminated with customer specified connector. Typical weight is 70 grams only, with­out cable.
AGENCY Approvals
The charger is certified by competent agencies to comply with most popular safety and EMC re­quirements, including but not limited to:
EN60950 UL1950 ETS300-342-1 FCC part 15 (specific version upon request)
ELECTRICAL CHARACTERISTICS
(Tamb=25
o
C, unless otherwise specified.)
Symbol Parameter Test Condition Min. Typ. Max. Unit
Vi Input Voltage 90 264 Vrms Vo Output Voltage limit No load 7.6 8.0 8.4 V Io Output Current limit 1<Vout<Vo limit 600 700 800 mA Vor Output Ripple Io=Ilimit Vbatt=4V 100 mVpp
Vis Isolation voltage
Input to output, t=60s (EN60950)
3000 Vrms
Top
Operating Ambient Temperature
050
o
C
Tstg Storage Temperature Range -20 70
o
C
n efficiency 75%
Vo (V)
Io (mA)
8
700
TYPICAL OUTPUT CHARACTERISTIC
MISTRAL