SGS Thomson Microelectronics GS-GHIBLI Datasheet

FEATURES
LINE VOLTAGE 90 - 264 VAC SINGLE OUTPUT MAX 8W DESIGNED FOR ON LINE CHARGING OF
MOBILE PHONES EMC COMPLIANCE ACCORDING TO EU
AND US DIRECTIVES SAFETY APPROVAL ACCORDING TO
SOUTH AFRICA AND CHINA MARKING UPON REQUEST
OUTPUT CURRENT AND VOLTAGE LEVELS ACCORDING TO CUSTOMER REQUIRE­MENTS
OUTPUT VOLTAGE PRECISI O N: +/- 5% OUTPUT CURRENT PRECISION : +/- 8% OUTPUT RIPPLE VOLTAGE <100 mVpp INPUT FUSE PROTECTION OUTPUT SHORT CIRCUIT PROTECTION RG11 OUTPUT CONNECTOR ONLY WITH
EURO PLUG. 2-WIRES DC CORD WITH STRAIN RELIEF
TERMINATED WITH ANY CUSTOM CON­NECTOR AVAILABLE UPON REQUEST. A VARIETY OF PLUGS CAN BE ASSEMBLED ON THIS VERSION.
LOW STAND BY PO W ER
DESCRIPTION
The Fast Charger GHIBLI has been designed for charging all types of batteries, including NiMH, NiCd and Li-Ion batteries in hand held mobile phones. GHIBLI is a high performance high effi­ciency AC/DC switching mode constant v oltage & current generator. The output voltage and current levels are set up by design in accordance with customer requirements.
Typical reference values in this data sheet are 10V, 800 mA with the input Vac ranging from 9 0 to 264 Vrms.
January 2000
®
PRODUCT VIEW
(Ghibli Housing with RG11)
ORDERING NUMBER: GSAC-xxCCCy
GHIBLI
AC/DC UNIVERSAL FAST CHARGER
Rev. 01
Plug Type: Part Number:
EURO GSAC-xxCCC1
xx = Output Current level (2 Digits) CCC= Customer Identifier (3 Digits) y = plug type
1/4
Coming into the small Ghibli housing, this fast charger is equipped with the E uropean AC plug. Interface to the phone is ensured via a RG11 connector. However, the same electronic platform can be assembled upon customer request into the Robin housing. The Robin housing can be as­sembled with a variety of AC plug (UK, US, Aus­tralia, South Africa/India,and China), interface to the phone is ensured via a 2 wires cord with strain relief, terminated with customer specified connector. Typical weight is 70 grams only, with­out cable.
AGENCY Approvals
The charger is certified by competent agencies to comply with most popular safety and EMC re­quirements, including but not limited to:
EN60950 UL1950 ETS300-342-1 FCC part 15 (specific version upon request)
ELECTRICAL CHARACTERISTICS
(Tamb=25
o
C, unless otherwise specified.)
Symbol Parameter Test Condition Min. Typ. Max. Unit
Vi Input Voltage 90 264 Vrms Vo Output Voltage limit No load 9.5 10.0 10.5 V Io Output Current limit 1<Vout<Vo limit 740 800 860 mA Vor Output Ripple Io=Ilimit Vbatt=4V 100 mVpp
Vis Isolation voltage
Input to output, t=60s (EN60950)
3000 Vrms
Top
Operating Ambient Temperature
050
o
C
Tstg Storage Temperature Range -20 70
o
C
Vo (V)
Io (mA)
10
800
TYPICAL OUTPUT CHARACTERISTIC
GHIBLI
2/4
Loading...
+ 2 hidden pages