SGS Thomson Microelectronics GS1T70-D540-1 Datasheet

GS1T70-D540/1
ISDN DC-DC CONVERTER
January 1996 1/4
Type V
i
V
o
o
GS1T70-D540/1 25 to 115V
5 V 90 mA
40 V 10,5 mA
FEATURES
Wide operating line terminationvoltage Peak input ove rvoltage withstand: 1kV for
1.2/50µs Peak overvoltage withstand on Output 2 (40V): 250V for 10/700µs Positiveor negative input voltage polarity Input andoutput filtering Short-circuitprotection on both outputs Input power during shortcircuit within specifica­tion Minimum currentdrain duringstand-by condition: 10µAfor Vi<18V Input-output isolation voltage: 2000V
RMS
for 60 seconds Output1-output2 isolation voltage: 2000V
RMS
for 60 seconds Mechanical dimensions (L x W x H): 50.8 mm x
50.8 mm x 18 mm (2” x 2” x 0.71”)
DESCRIPTION
TheGS1T70-D540/1converter hasbeen designed for the “U” interface of an ISDN-NTBA (Network Termination BasicAccess)systemwith either4B3T or 2B1Q standard trasmission.
It meets the requirements of the following specifi­cations:
EN 60950 CCITTI.430 CCITTG.960 CCITTG.961 ETS 300 002 ETS 300 012 ETS 300 047 (ISDN BASIC ACCESS, Safety and
Protection) Two isolated outputs, 5V/90mA and 40V/10.5mA
aresupplied. The converter offers short-circuitpro­tection (short-circuit on 40V output doesn’t affect 5Voutputandthe input power never exceeds the
limitofthe specification), input eithervoltagepolar­ity,80%minimum efficiencyatmaximumload,input and output filtering to meet very stringent noise requirements.
The input and the output 2 (40V) stages are pro­tected against differential overvoltage up to 1kV (1.2/50µs)and 250V (10/700µs) respectively.
When the input voltageis below 18V,the converter offersa veryhigh input impedanceand amaximum quiescent current of 10µA.
These features allow the converter to operate di­rectly connected to the telephone line without any external components.
In addition, the wide operatinginputvoltage range allows it to operate within the whole range of LT (Line Termination) battery voltage and its relevant line resistance.
2000V
RMS
isolation voltage for 60 second is pro­videdbetween inputto outputsandbetween output 1 and output 2.
ELECTRICAL CHARACTERISTICS (T
amb
=25°Cunless otherwisespecified)
Std. Conditions: LineTermination voltage:47 to 71V Line Resistance (Rs): 10 to 560
87 to 99V 550 to 1400
Symbol
Parameter TestConditions Min Typ Max Unit
V
i
Input Voltage Std. Conditions
25 115 V
V
ipk
Input Transient Overvoltage
t = 1.2/50µs (pulse)
1kV
V
ist
Start UpInput Voltage
See fig.2
28 44 V
V
o1
Output Voltage 1 Std. Conditions
4.75 5 5.25 V
V
o2
Output Voltage 2 Std. Conditions
34 40 42 V
V
or1
Output Ripple Voltage 1
Std. Conditions BW= 0 to 20MHz
5 20 mVpp
V
or2
Output Ripple Voltage 2
Std. Conditions BW= 0 to 20MHz
10 30 mVpp
eN
Input Noise Voltage Std. Conditions
BW= 0 to 20MHz
10 30 mVpp
o1
Output Current 1 Std. Conditions
Io2= 0 to 10.5 mAVo1=5V
290mA
I
o1I
Output Current 1 Limit Initiation
Std. Conditions Vo1= 4.75 to 5.25V
110 130 mA
o2
Output Current 2 Std. Conditions
Io1= 2 to 90 mA Vo2= 40V
0 10.5 mA
osc2
Output 2 Short CircuitCurrent
Std. Conditions Output Shorted (Indefinite time)
914mA
V
is
Isolation Voltage (pulse)
Input to Output1 Input to Output2 Output 1 to Output2
2000 V
RMS
T
op
OperatingAmbient TemperatureRange
0 +80 °C
T
stg
Storage TemperatureRange
– 40 +85 °C
2/4
LT (Line Termination Voltage)= 47V to 71V
Rs (Line Resistance) = 10 to 560
LT(Line TerminationVoltage) = 87V to 99V
Rs (LineResistance)= 550 to 1400
Max
Input
Power
(mW)
NT Status
Min
Output
Power1
(5V)[mW]
Min
Output
Power2
(40V)[mW]
Max
Input
Power
(mW)
NT Status
Min
Output
Power 1
(5V)[mW]
Min
Output
Power 2
(40V)[mW]
450 Activated 320 0 450 Activated 320 0 950 Activated Emergency 330 410 950 Activated Emergency 330 410
90 Deactivated 25 0 90 Deactived 25 0
180 DeactivatedEmergency 25 45 180 DeactivatedEmergency 25 45 950
Activated with 40 V
Short circuit
330
Short
circuit
950
Activated with 40V
Short circuit
330
Short
circuit
OUTPUT POWERCHARACTERISTICS
GS1T70-D540/1
Loading...