MAIN PRODUCTS CHARACTE RISTICS
DTVseries
(CRT HORIZO N TAL DEF LEC T ION)
HIGH VOLTAGE DAMPER DIODE
I
F(AV)
V
RRM
V
F
5 A to 10 A
1500 V
1.3 V to 1.5 V
FEATURES AND BENEFITS
HIGH BREAKDOWN VOLTAGE CA PABILITY
VERY FAST RECOVERY DIODE
SPECIFIED TURN ON SWITCHING
CHARACTERISTICS
LOW STATIC AND PE AK FORWARD VOLTAGE
DROP FOR LOW DISSIPATION
SUITED TO 32-110kHz MONITORS AND
16kHz TV DEFLECTION
INSULATED VERSION (ISOWA TT220AC):
Insulating voltage = 2000V DC
Capacitance = 12pF
PLANAR TECHNOLOGY ALLOWING HIGH
QUALITY AND BEST ELECTRICAL
CHARACTERISTICS
A
TO-220AC
DTVxxxD
A
K
ISOWATT220AC
DTVxxxF
K
DESCRIPTION
High voltage diode with high current capability
dedicated to horizontal deflection. DTV16 is
optimized to TV meanwhile DTV32 to DTV110 are
covering the full range of monitors from the low
end to the professional hi-definition SXGA CAD
display units.
These devices are packaged either in TO220-AC
or in ISOWATT220AC.
ABSOLUTE RATINGS
Symbol Parameter Value Unit
V
RRM
I
F(RMS)
I
FSM
Repetitive peak reverse voltage 1500 V
RMS forward current 15 A
Surge non repetitive forward current
tp = 10ms half sine wave
DTV16 50 A
DTV32 75
DTV56 80
DTV64 80
DTV82 80
DTV110 80
T
stg
T
j
August 1999 - Ed: 2B
Storage temperature range -65 to 150 ° C
Maximum operating junction temperature 150 ° C
1/10
DTVseries
THERMAL RESISTANCES
Symbol Parameter
R
th(j-c)
Junction to case thermal
resistanc e
STATIC ELECTRICAL CHARACTE RISTICS
Symbol Test Conditions
V
F *
I
R **
pulse test : * tp = 380 µs, δ < 2%
** tp = 5 ms, δ < 2%
IF = 5 A DTV16 1.6 1.0 1.5 V
= 6 A DTV32 1.5 1.1 1.35
I
F
= 6 A DTV56 1.8 1.1 1.5
I
F
= 6 A DTV64 1.7 1.1 1.4
I
F
= 6 A DTV82 1.8 1.0 1.3
I
F
= 10 A DTV110 2.3 1.15 1.5
I
F
VR = V
RRM
Value
TO-220AC ISOWATT220AC
Unit
DTV16 3 5.5 °C/W
DTV32 2.5 4.75
DTV56 2 4
DTV64 1 .8 4
DTV82 1.6 3.7
DTV110 1.3 3.5
Value
UnitTj = 25°C Tj = 125°C
Typ Max Typ Max
DTV16 60 100 500
A
µ
DTV32 100 100 1000
DTV56 100 100 1000
DTV64 100 100 1000
DTV82 100 100 1000
DTV110 100 100 1000
2/10
DTVseries
RECOVERY CHARA CTERISTICS
Symbol Test Conditions Typ Max Unit
t
rr
t
rr
IF = 100m A
I
= 100mA
R
I
= 10mA
RR
IF = 1 A
dI
/dt =-50A/µs
F
V
=30V
R
TURN-ON SWITCHING CHARACT ERISTICS
Tj = 25°C DTV16 1500 ns
DTV32 850
DTV56 750
DTV64 750
DTV82 675
DTV110 625
Tj = 25°C DTV16 200 300 ns
DTV32 130 175
DTV56 110 135
DTV64 110 135
DTV82 105 125
DTV110 95 115
Symbol Test Conditions Typ Max Unit
t
fr
IF = 6 A
dI
/dt = 80 A/µs
F
V
=3V
FR
Tj = 100°C DTV16 350 ns
DTV32 570
DTV56 350
DTV64 350
DTV82 270
DTV110 250
V
FP
IF = 6A
dI
/dt = 80 A/µs
F
Tj = 100°C DTV16 25 34 V
DTV32 21 28
DTV56 19 26
DTV64 18 22
DTV82 14 18
DTV110 11 14
To evaluate the maximum conduction losses use the following equation :
DTV16 P= 1.14 x I
DTV32 P= 1.069 x I
DTV56 P= 1.15 x I
DTV64 P= 1.06 x I
DTV82 P= 1.01 x I
DTV110 P= 1.12 x I
F(AV)
F(AV)
F(AV)
F(AV)
F(AV)
F(AV)
+ 0.072 x I
+ 0.047 x I
+ 0.059 x I
+ 0.053 x I
+ 0.048 x I
+ 0.038 x I
F2(RMS)
F2(RMS)
F2(RMS)
F2(RMS)
F2(RMS)
F2(RMS)
3/10