74V1T79
3/9
DC SPECIFICATIONS
AC ELECTRICAL CHARACTERISTICS (Input t
r
= tf = 3ns)
(*) Vol tage range is 5.0V ± 0.5V
CAPACITIVE CHARACTERISTICS
1) CPD is defined as the value of the IC’s internal equivalent capacitance which is calculated from the operating current consumption without
load. (R ef er to Test Circuit). Average operating current can be obtained by t he following equation. I
CC(opr)
= CPD x VCC x fIN + I
CC
Symbol Parameter
Test Condition Value
Unit
V
CC
(V)
T
A
= 25°C
-40 to 85°C -55 to 125°C
Min. Typ. Max. Min. Max. Min. Max.
V
IH
High Level Input
Voltage
4.5 to
5.5
222V
V
IL
Low Level Input
Voltage
4.5 to
5.5
0.8 0.8 0.8 V
V
OH
High Level Output
Voltage
4.5
IO=-50 µA 4.4 4.5 4.4 4.4 V
4.5
I
O
=-8 mA 3.94 3.8 3.7
V
OL
Low Level Output
Voltage
4.5
IO=50 µA 0.0 0.1 0.1 0.1 V
4.5
I
O
=8 mA 0.36 0.44 0.55
I
I
Input Leakage
Current
0 to
5.5
V
I
= 5.5V or GND
± 0.1 ± 1.0 ± 1.0 µA
I
CC
Quiescent Supply
Current
5.5
V
I
= VCC or GND
11020µA
I
CC
Additional Worst
Case Supply
Current
5.5
One Input at 3.4V,
other input at V
CC
or GND
1.35 1.5 1.5 mA
Symbol Parameter
Test Condition Value
Unit
V
CC
(V)
C
L
(pF)
T
A
= 25°C
-40 to 85°C -55 to 125°C
Min. Typ. Max. Min. Max. Min. Max.
t
PLH tPHL
Propagation Delay
Time CK to Q
5.0 (*) 15 3.9 5.5 1.0 6.5 1.0 7.5 ns
5.0 (*) 50 4.5 6.5 1.0 7.5 1.0 8.5
t
W
CK Pulse Width,
HIGH or LOW
5.0 (*) 3.0 3.0 3.0 ns
t
s
Setup Time D to
CK, HIGH or LOW
5.0 (*) 2.0 2.0 2.0 ns
t
h
Hold Time D to CK,
HIGH or LOW
5.0 (*) 1.0 1.0 1.0 ns
f
MAX
Maximum Clock
Frequency
5.0 (*) 50 120 180 120 120 MHz
Symbol Parameter
Test Condition Value
Unit
T
A
= 25°C
-40 to 85°C -55 to 125°C
Min. Typ. Max. Min. Max. Min. Max.
C
IN
Input Capacitance
4101010pF
C
PD
Power Dissipation
Capacitance
(note 1)
8pF