SG Electronics SGCLK048, SGCLK044 User Manual

Digital Clock
Main Clock
GPS
Clock 1
Clock 2
Clock 3
Clock 4
User Manual
SG Electronics, A-93, e -83, Phase-II, NOIDA- , INDIA
S c. 201305 G. B. Nagar (U.P.), , Phone: 0120-4278002
Specification
Hardware Design & Installation
LED bar
4 * 2.3
4 Digit
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Display Digit
LED matrix
LED matrix
Digit Size (in Inches)
Number of Alarms
6 * 4
Clock Size (L*H*D, in Inches)
Time Format
12 Hrs & 24 Hrs
12 Hrs. & 24 Hrs.
12 Hrs. & 24 Hrs.
Power Requirement
220V, 50Hz AC+10%
220V, 50Hz AC +10%
220V, 50Hz AC+10%
Suspension Method
Mounting
Hanging
Hanging
Calibration:
I) Through key panel
II) RS232 Interface With Computer
III) GPS Synchronization
In Build
In Build
In Build
In Build
In Build
In Build
In Build
In Build
In Build
Optional
Optional
Optional
Optional
Optional
Optional
Synchronization between clocks:
I) Through Wired Link (interface only)
II) Through Wireless link
Alarm Output
220 V AC
8 * 4.5
34.25*10.125*3
30.25*8.125*3
18.25*7.25*3
220 V AC
220 V AC
16
16 16
4 Digit
4 Digit
Serial
Features
SGCLK044 SGCLK046 SGCLK048
Height
7.25
Lenght
18.25
Width
3
SGCLK044
Height
8.125
Lenght
30.25
Width
3
SGCLK046
Height
10.125
Length
34.25
Width
3
SGCLK048
Mounting Process
Antenna Setting
GPS Setting
2
1
1
3
1
1
2
2
2
3
Hanging Method
Wire / Wireless Conection Process
Cable Connectivity Details
GPS Calibration
MAINS 220VAC
SET
1
2
3
4
5
SG
Solution Galore
S.G.Electronics
www.sgelectronics.co.in
DIGITAL CLOCK
MODEL: SGCLK04
Sl. No.:
1-
2-
3-
4-
5-
(
)
TX
RX
GND
(
)
220V, 6A
AC, O/P
L
N
1
2
3
4
5
1 -
2 -
3 -
4-
5-
(
)
TX
RX
GND
(
)
220V, 6A
AC, O/P
L
N
Power Connection 220V, 50Hz, ±10%
Alarm Sound Output Connection (220 V Ac 6 Amp )
GPS
Main Clock
Clock 1
Clock 2
Clock 3
Clock 4
Clock Key Calibration
Clock Key Calibration
Wire Connectivity
Wire Connectivity
Wire Connectivity
Computer Calibration
Computer Calibration
GPS Calibration
GPS Calibration
Master Clock
Master Clock
Wireless Connection
Master Clock
Wireless Connection
Slave Clock
Slave Clock
2
2
2
Slave Clock
1
2
3
4
5
Master Clock
Slave Clock
Slave Clock
Slave Clock
Slave Clock
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1-
2-
3-
4-
5-
(
)
TX
RX
GND
(
)
220V, 6A
AC, O/P
L
N
220V, 6A
AC, O/P
220V, 6A
AC, O/P
220V, 6A
AC, O/P
220V, 6A
AC, O/P
220V, 6A
AC, O/P
1
2
3
4
5
Computer Clock
Slave Clock
Slave Clock
Slave Clock
Slave Clock
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1-
2-
3-
4-
5-
(
)
TX
RX
GND
(
)
220V, 6A
AC, O/P
L
N
1
2
6
3
7
4
8
5
9
1 2 3 4 5 6 7 8 9
Transmitted Data(TX)
Signal Ground(GND)
Receive Data(RX)
PIN
SIGNAL
220V, 6A
AC, O/P
220V, 6A
AC, O/P
220V, 6A
AC, O/P
220V, 6A
AC, O/P
1
2
3
4
5
Master Clock
Slave Clock
Slave Clock
Slave Clock
Slave Clock
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1-
2-
3-
4-
5-
(
)
TX
RX
GND
(
)
220V, 6A
AC, O/P
L
N
220V, 6A
AC, O/P
220V, 6A
AC, O/P
220V, 6A
AC, O/P
220V, 6A
AC, O/P
220V, 6A
AC, O/P
Alarm Duration
Click here to set time format
Click here to check com port connectivity
Click here to Update Clock
Click here to set 16 Alarm
Click here to set alarm duration
Select COM Port
Update Clock
Exit
Alarm 1 time:
Alarm 9 time:
Alarm 2 time:
Alarm10 time:
Alarm 3 time:
Alarm 11 time:
Alarm 4 time:
Alarm12 time:
Alarm 5 time:
Alarm 13 time:
Alarm 6 time:
Alarm 14 time:
Alarm 7 time:
Alarm 8 time:
Apply
Reset All
Exit
Alarm15 time:
Alarm 16 time:
Apply
Select Time Format
Configure Time
Configure Time
Configure Alarm
Configure Alarm
12-Hrs
O
/
I
SG
Solution Galore
SG
Solution Galore
SG Electronics
The Industrial Automation Needs
SG Electronics
The Industrial Automation Needs
0 Sec
( in Seconds )
Clock Interface powered by SG Electronics
Clock Interface powered by SG Electronics
13:30 13:30 13:30
13:30
13:30
13:30
13:30
13:30
13:30
13:30
13:30
13:30
13:30
13:30
13:30
13:30
GUI Application Calibration
Key Calibration
Step1: First Press SET Key and switch ON digital Clock with holding SET for 2 Second continuously.
Step2: After 2 second, Digital Clock Minute Panel will be Blinking for time calibration.
Step3:First set minute, then Press SET Key for Hour calibration. After that press SET key for time calibrate and save into digital clock with 00 second by default.
Time Format Setting :
Step1: First press SET Key and Switch ON Digital clock and holding the SET key for 10 Second Continuously. Step2: After 10 second Digital clock screen has show firstly
12HR / 24HR With Blinking digit. Step3:after that we choose 12hr & 24 hr time format by pressing Down and UP keys. Step4: After Choose time format Press SET key for setting time format save into digital clock.
Step1: First switch ON digital clock properly, then press SET key. Step2: After Press SET key , digital clock screen has show AL 1(Alarm1). Step3:After 2 second alarm time calibration will be show with blinking digit of minute.
Step4 : after that minute will be setting by pressing DOWN and UP key then, press SET key for Hours setting.
After setting hours into digital clock press SET key for other 15 alarm time Setting. Step6: Rest all 15 Alarm setting follow through exact instruction of alarm1. Step7: After 16 Alarm time setting ,Alarm on will be show, which is represents to alarm duration setting that is minimum 0 second and maximum 59 second.
1. Alarm time is always in 24 hrs format and this clock initially on any inbuilt alarm, for alarm it provides 220V AC 6 Amp output.
2. By default time of the clock is calibrated with format of 12 hrs with no alarm set.
3.If we set alarm 00:00 then alarm does not work.
*
*
*
*
In duration of setting, if we no touch any key of digital clock for 5 Second, digital clock auto go back to main time screen.
Application
06:28 PM
06:28 PM
Alarm Time Setting:
Note:
Time Calibration:
School Hospital Firm / Industries Transport Broadcast & Telecast Defense
Apply
Loading...