SFC Energy EFOY 600, EFOY 900, EFOY 1600, EFOY 1200, EFOY 2200 User Manual

User Manual
EFOY 600 / EFOY 900 / EFOY 1200 / EFOY 1600 / EFOY 2200
ENGLISH
1. Table of Contents
2
1. Table of Contents
1. Table of Contents 2
2. Introduction 4
2.1 Foreword 4
2.2 Safety Information 5
2.3 Safety notice for methanol 7
2.4 Normal Operation 7
2.5 Declaration of Conformity 8
2.6 Seals of Approval 8
2.7 Warranty 9
2.8 Warranty extension 9
2.9 Disposal 10
3. Configuration 11
3.1 Standard Equipment 11
3.2 Overview 12
3.3 Remote Control 12
3.4 Specifications 13
4. Installation 15
4.1 Tools and Materials 15
4.2 Space Requirements 16
4.3 Securing the unit 17
4.4 Off-heat duct 18
4.5 Connecting the Exhaust Hose 19
4.6 Installing the fuel-cartridge holder 21
4.7 Electrical Connections 22
4.8 Connection via the Central Electrical Box (EBL) 23
4.9 Connection directly to the battery 24
4.10 Connecting the Remote Control 25
5. Operation 27
5.1 Connecting the Fuel Cartridge 27
5.2 Select Language 30
5.3 Display Information 31
5.4 Automatic Operation 32
5.5 Switching on the Fuel Cell 33
5.6 Switching Off the Fuel Cell 34
5.7 Battery protection 35
5.8 Automatic Antifreeze Feature 36
English
1. Table of Contents
3
5.9 Storage 37
6. Maintenance 39
6.1 Service 39
6.2 Cleaning 40
7. Troubleshooting 41
7.1 Safety 41
7.2 Problems and Solutions 42
7.3 Problems without Error Messages 44
7.4 Replacing Service Fluid 45
8. Appendix 47
8.1 Output characteristic 47
2. Introduction
4
2. Introduction
2.1 Foreword
Thank you for purchasing an EFOY product. We hope that you will enjoy your new unit.
Please read these instructions first before using.
Should you have any questions about installation or operation, please consult the EFOY hotline.
SFC Energy AG Eugen-Sänger-Ring 7 D-85649 Brunnthal-Nord
Hotline: +49 89 / 673 5920 Freecall: 00800 / 732 762 78* Fax: +49 89 673 592 369 hotline@efoy.com www.efoy.com
*The toll-free number is available in the following countries: Germany, Belgium, Denmark, France, Great Britain, Italy, the Netherlands, Norway, Austria, Sweden, Switzerland and Spain.
English
2. Introduction
5
2.2 Safety Information
Read the instructions before operating and keep them nearby. Be sure to follow all directions in the manual.
Do not open unit or fuel cartridges. Do not use force to open cartridges and do not refill them. Any modifications to the unit may affect safe operation, will lead to a loss of license and will void the warranty Use only original EFOY equipment. Do not store unit and fuel cartridges at temperatures above 45° C. Do not operate at temperatures above 40° C. Keep away from heat and direct sunlight.
Store the unit where there is no danger of freezing, or use the automatic antifreeze feature.
Do not smoke when handling the unit or the fuel cartridges. Keep away from heat and open flame.
There is a danger of fire if methanol leaks out following an accident, or if the unit or the fuel cartridge has been damaged. Keep away from open fire and make sure area is well ventilated. Small amounts of methanol which may leak out will evaporate without leaving any residue.
Keep unit and fuel cartridges (including empty or partially filled cartridges) out of children’s reach.
Operate the unit only in accordance with instructions and keep operating area well ventilated. Do not block exhaust. Avoid inhaling exhaust fumes directly or for prolonged periods of time.
2. Introduction
6
There is no risk of coming into contact with methanol provided that you handle the unit and fuel cartridges in accordance with instructions.
We are required by law to print the following notice.
Methanol is toxic if inhaled, ingested or if it comes into contact with skin. Irreparable damage may occur if inhaled, ingested or if it comes into contact with skin. In the event of an accident or if nausea occurs, consult a physician immediately. Be sure to bring the fuel cartridge label or these instructions to the consultation.
System exhaust may contain harmful components. Avoid inhaling exhaust directly or for prolonged periods of time. Use the exhaust hose to conduct exhaust gases to the exterior.
Improper use or improper connection to other electrical devices may result in damage.
WARNING
In addition to these safety instructions, please observe the passages in bold type. Otherwise, you may endanger yourself and others.
English
2. Introduction
7
2.3 Safety notice for methanol
WARNING
You are given the methanol in the form of safe, tested fuel cartridges that protect you from coming into direct contact with the contents if used correctly. We are required by law to print the following notice.
Methanol is easily flammable. Methanol is toxic if inhaled, ingested or if it comes into contact with skin.
In the event of an accident or if nausea occurs, consult a physician immediately. Be sure to bring the fuel cartridge label or the methanol material safety data sheet to the consultation.
Storage and transport of methanol may be subject to statutory regulations.
More information is provided in the methanol safety data sheet on our website www.efoy.com or by SFC directly
2.4 Normal Operation
The EFOY 600, EFOY 900, EFOY 1200, EFOY 1600 and EFOY 2200 are automatic charging devices for 12V lead batteries.
The unit may be used only to charge lead batteries that conform to the specifications in Chapter 3.4, page 13).
The specifications allow for solid-state operation (see Chapte
r 3.4) on boats and on motor vehicles. Operate only
with original-equipment EFOY fuel cartridges.
The unit is not intended for emergency medical power generation, or for powering life-sustaining or agricultural devices.
2. Introduction
8
It is permissible to connect units in parallel to increase the charging current.
The series connection of units to increase the voltage is not permitted.
Do not operate unit if housing is damaged.
2.5 Declaration of Conformity
SFC Energy AG, Eugen-Saenger-Ring 7, 85649 Brunnthal­Nord declares that the EFOY 600, EFOY 900, EFOY 1200, EFOY 1600 and the EFOY 2200 conform to the European Community’s 2004/108/EG guidelines for electro­magnetic compatibility. The following norms apply: DIN EN 61000-6-1, DIN EN 61000-6-3
2.6 Seals of Approval
These units have been tested in accordance with ECE Regulation No. 10 for electro-magnetic compatibility. Operation in motor vehicles is permitted.
Approval number: E24 10R-020234
These units have undergone voluntary testing by TÜV SÜD for conformity with the basic requirements of IEC 62282-5 and have been awarded the seal of approval for product safety.
E 24
English
2. Introduction
9
2.7 Warranty
The warranty period begins when the new unit is purchased. Your proof of purchase (receipt, invoice, etc.) can be used as a record of this date. Please keep these documents carefully. Our warranty services are based on the SFC warranty conditions which are valid at the time of purchase.
Service
For technical queries on EFOY fuel cells, our EFOY customer service can be reached during office hours at the following numbers:
Freecall (Germany): 00800 / 73 27 62 78*
From any other country, please dial: +49 89 / 673 5920
SFC Energy AG Eugen-Sänger-Ring 7 85649 Brunnthal-Nord Germany Fax.: +49 89 / 673 592 369 sales@efoy.com www.efoy.com
*The freecall number is available from the following countries: Germany, Belgium, Denmark, France, Great Britain, Italy, the Netherlands, Norway, Austria, Sweden, Switzerland and Spain.
2.8 Warranty extension
The EFOY warranty certificate gives you maximum security and reliable service. When you pay the one-off fee, you receive the EFOY warranty certificate for a 5-year manufacturer’s warranty. The EFOY warranty certificate is available directly from SFC Energy AG, the manufacturer of EFOY fuel cells.
Simply fill in the form at www.garantie.efoy.com/en or call +49 89 / 673 5920 for further information.
2. Introduction
10
2.9 Disposal
Packaging
Packaging protects your unit during shipping. All materials used are environmentally compatible and recyclable.
We recommend saving the packaging for eventual winter storage.
Should you nevertheless wish to dispose of the packaging, please do so properly.
Your dealer or your local recycling center can provide information about proper disposal.
WARNING
Danger of Suffocation!
Keep packaging away from children. Plastic wrapping and cartons may cause suffocation.
Fuel Cartridges
Sort empty fuel cartridges with plastics. Dispose of partly filled fuel cartridges in the same manner as solvents or paint.
Old Units
Old units are still valuable! Proper disposal can yield valuable raw materials while protecting the environment.
The EFOY hotline:
Tel.: +49 89 / 673 5920 or 00800 / 732 762 78*
can advise you about returning old units.
English
3. Configuration
11
3. Configuration
3.1 Standard Equipment
The following is standard equipment:
Unit Remote control with data line RC1 (10 metres long) Fuel-cartridge holder with belt FH 1 Mounting plate with belt MP 1 Exhaust hose (1.5 m) EH 1 Off-heat duct OD1 (consisting of off-heat flange, off-
heat bow, off-heat tube, external cover and fixing screws)
Service fluid UM1 user manual Charge line CL4
Unit
Remote control with data line
RC1
Fuel-cartridge holder with
belt FH1
Mounting plate with belt MP1
Exhaust hose EH1
Off-heat duct OD1
Service kit
Charge line CL4:
Connecting line to fuel-cell 1m
Battery fuse power 15 A Battery fuse sense 2.0 A Length 0,5m Length 0,5m
3. Configuration
12
3.2 Overview
1 Charge line connection 2 Remote-control connection RC 1 3 Data interface 4 Fuel-cartridge connection 5 Connection for EH 1 exhaust hose and nozzle for
service fluid 6 Cooling inlet (reverse) 7 Warm-air outlet and connection for off-heat duct
3.3 Remote Control
auto
reset
!
1 Display
2 Information button and language-selection button >> 3 On/Off button 4 Button for automatic operation auto 5 Yellow warning light “Please change fuel cartridge“ 6 Red error warning light 7 Reset button reset
English
3. Configuration
13
3.4 Specifications
Performance
Product
EFOY 600 EFOY 900 EFOY 1200 EFOY 1600 EFOY 2200
Rating 25 W 38 W 50 W 65 W 90 W
Charge capacity
600 Wh/Day
(50 Ah/Day)
900 Wh/Day
(75 Ah/Day)
1200 Wh/Day
(100 Ah/Day)
1560 Wh/Day
(130 Ah/Day)
2160 Wh/Day
(180 Ah/Day)
Nominal voltage 12 V 12 V 12 V 12 V 12 V
Charging current @ 12 V
2.1 A 3.1 A 4.2 A 5.4 A 7.5 A
Turn on threshold* U
batt
< 12.3 V U
batt
< 12.3 V U
batt
< 12.3 V U
batt
< 12.3 V U
batt
< 12.3 V
Cut off threshold* U
batt
>14.2 V U
batt
>14.2 V U
batt
>14.2 V U
batt
>14.2 V U
batt
>14.2 V
Required starting voltage
>9 V >9 V >9 V >9 V >9 V
Quiescent current requirement
15 mA 15 mA 15 mA 15 mA 15 mA
Methanol requirement 0.9 l/kWh 0.9 l/kWh 0.9 l/kWh 0.9 l/kWh 0.9 l/kWh
12 V rechargeable (lead-acid or lead-gel) batteries
Compatible batteries**
10 - 100 Ah
15 - 150 Ah 20 - 200 Ah 40 - 250 Ah
60 - 350 Ah
General Specifications
Sound pressure level at 7 m
23 dB(A) 23 dB(A) 23 dB(A) 23 dB(A) 23 dB(A)
Weight 6 kg 6.2 kg 7.4 kg 7.6 kg 7.9 kg
Dimensions (LxWxH) 43.5 x 20.0 x 27.6 cm
Environmental conditions
Space requirement (LxWxH)
51 x 35 x 30 cm (minimum)
Inclination along the direct axis
continual: 35° temporary (<10min): 45°
Inclination along the quadrature axis
continual: 20°
Operating temperature -20 to +40 °C
Start temperature +5 to +40 °C
Storage temperature +1 to +45 °C
* factory setting - can be modified with Interface Adapter and PC
** The default values are preset optimally ex works for the specified battery sizes. If the battery capacities deviate greatly from these sizes, please contact your specialist retailer.
3. Configuration
14
Instrumentation
Operation via remote control with four buttons and multilingual display
Electrical interface MNL 4-prong plug
Type Tyco Electronics AMP Universal Mate-N-Lok (Mfr. No. 350779)
Fuel Cartridge M5 M10
Volume 5 liter 10 liter
Weight 4.3 kg 8.4 kg
Dimensions (L x W x H) 19.0 x 14.5 x 28.3 cm 23.0 x 19.3 x 31.8 cm
English
4. Installation
15
4. Installation
WARNING
Securely fasten unit and fuel cartridges when using on board motor vehicles.
Do not operate unit if there is danger of explosion.
Unit is not watertight. Make sure that no water can enter.
Keep unit and fuel cartridges away from children, temperatures in excess of 45° C and direct sunlight.
4.1 Tools and Materials
You will need the following tools and sealants to install the fuel cell:
electric drill jigsaw screwdriver hexagonal (Allen) wrench sealant such as Sikaflex
Use the following screws, depending on the mounting surface (screws are not included):
8 screws to attach the mounting plate4 screws to attach the remote control4 screws to attach the fuel-cartridge holdercable clamps and fixing screws, if needed
Loading...
+ 35 hidden pages