Seuic AUTOID 6 Series, AUTOID 6C Series Quick Start Manual

JIANGSU SEUIC TECHNOLOGY CO., LTD
Company address: NO.15.Xinghuo Road Nanjing New High Technology Industry Zone, Nanjing City, Jiangsu Province, China Hotline: 0086-400-777-0876 Company official website: www.seuic.com Products official website: www.chinaautoid.net Mailbox: AUTOID@seuic.com Post code: 210061
JIANGSU SEUIC TECHNOLOGY CO., LTD
QUICK START GUIDE
Charging indicator
Scan indicator
Touch Screen
Scan button
Stylus Silo
Install battery and battery cover
Take out the device, the battery and the stylus from the package, install the battery and battery cover in according to the instruction signs.
Initial Use
Please ensure the battery is fully charged to boost up the system.
Power on
Press the Power on/off button until the PDA vibrates.
Power off
Power on/off
End flap cable port
Apply series:
AUTOID® 6 series
AUTOID® 6C series
Hand belt fixing base
SIM card slot
Memory card slot
Fig. 2
Press the power on/off button for 3 seconds, tap Off on the prompted operation interface and the device shuts off. Or press the Power on/off button for at least 5 seconds, the indicator on the right corner goes off and device shuts off.
Sleep Mode
Press the Power on/off for 1 second during working status, the device enters into sleep mode. Or the users can press the Power on/off for at least 3 seconds for the promoted operation interface, tap Sleep Mode to enter into sleep.
Reset the device
How to reset the device:
Either scan button on both sides of the device. Keyboard scan button.
Keyboard power button. Press and release the above mentioned three keys at the same
time to reset the device.
Install SIM card and memory card
Under the battery, SIM card to be inserted into the left slot while memory card the right slot. Pull the card down as instructed, lift the card cap and insert the corresponding card, put down the cap and fasten it. The device does not support hot plug, please reset the system after accident hot-plug.
Charge the device
Charging dock : Place the device on the charging dock and connect the dock to the power supply. Red indicator of the charging dock means it is being charged; green indicator means it has been full charged.
End flap cable: Connect the device with power supply by the end flap cable, red indicator means under charging while green means it has been fully charged. NOTE: If the device be idle for quite long time, please charge it at least once every two months to avoid over discharging.
Charge the battery
Place the battery on the charging dock and connect the charging dock to the power supply. Red indicator means under charging while green means it’s been fully charged.
Charging dock for device
Charging dock for battery
Power supply port
USB port
Serial interface
Power supply port
End flap cable connector
USB port
Common functions
Connect with PC
The device can be connected with the PC with ActiveSync4.5 (or the updated versions) in Windows XP system, and the integrated mobile control center for Window 7 system.
Mobile butler
Users can use Mobile Butler to manage the operation restriction of the installed applications in the device with the initial password “seuic”. The users can install any other Apps they prefer under Third Party App Management, and set the operation authority as “Show On desktop” and “Automatically open when power on” in according to their needs.
Notes: To ensure the third party App automatically on when power on, please checkmarked both Automatically On options on the device setting page and the App Management page.
Barcode scanning
SEUIC’s scan tool or customer’s scan tool are optional to use when scanning barcodes. Frequently Asked Questions;
1.There is no light when scanning. Problem shooting: please check whether the scan engine is closed, if closed, please go to Settings in scan tool to turn it on.
2. One scanning results in two barcodes. Problem shooting: please check if the built-in scan tool and the third party application are opened simultaneously. If yes, close the built-in scan tool and disable the “Automatically open when power on”.
WIFI connection
1. Please double-click “Wireless Manager” on the desktop. Make sure the WIFI status is “Disabled“.
2. Click the taskbar WIFI connection icon.
3. Select an AP, configure the user name and password to connect to the corresponding internet.
GPRS connection
1. Please double-click “Wireless Manager” on the desktop. Make sure the GPRS status is “Disabled”.
2. Insert the SIM card correctly, and restart the device.
3. After the restarting is completed, select the taskbar GPRS icon and double-click to dial-up the connection.
Frequently Asked Questions:
CE system stays in redial interface, please check whether the SIM card is out of service.
Attention
1. Please keep the USB cable and other charging accessories away from water.
2. Please do not delete any windows root directory system files.
3. Please close 2D scan device if not necessary. Keeping it open for a long time is not recommended.
4. Please do not look directly into the laser beam emitted from the scanner to avoid eye injury.
5. Please connect the USB cable to the device first before connecting it to the PC via USB port.
6. Please restart the device after replacing the SIM/SD card.
Trouble shooting
1. In case of GPRS dialing stagnates on the validation page, please check if your SIM card is out of service.
2. If the device is not successfully connected to the PC, please check whether the USB and the PDA are correctly connected.
3. If the device can’t enter into sleep mode, please check whether terminal is using cellular network or reading/writing data into NAND
Technical support
Please visit SEUIC official website www.chinaautoid.net to download User Manual, SDK, different APPs and software to help you better use the device. 2017 SEUIC Technology. All rights reserved. No part of this publication may be reproduced or used in any form, nor by any electrical means without permission in written.